1-6
Hardware Installation
Environmental Specifications
Environmental Specifications
Table 1-2.
Environmental Specifications
Table 1-3.
Maximum Advanced Services Modules
*Notes on the Advanced Services Module operating temperature:
1.
Operate at 50°C
a.
The Advanced Services Module can operate in an HP E5406 zl or
E5412 zl switch at up to 50°C
if
you install
all
Advanced Services
Modules on the left side of the chassis (when you face the front, or
port side, or the switch). In other words, the left side slots are A, C,
E, G, I, and K. See Figure 1-3 on page 1-7.
b.
If you want an E5406 zl switch to operate at up to 50°C, the switch
supports a maximum of three Advanced Services Modules (because
the switch has three slots on the left side).
2.
Operate at 45°C
a.
The 45°C limit applies to the E5406 zl and E5412 zl switches if
any
Advanced Services Modules are installed on the chassis’ right side,
which includes module slots B, D, F, H, J, and L. See Figure 1-3 on
page 1-7.
b.
The 45°C limit always applies to the E8206 zl and E8212 zl switches
no matter where you install the Advanced Services Modules.
Temperature
Operating*
0
°
C to 45
°
C (32
°
F to 113
°
F)
Non-Operating
-10
°
C to 65
°
C (-10
°
F to 149
°
F)
Relative humidity
(non-condensing)
15% to 90% at 40
°
C (104
°
F)
15% to 90% at 65
°
C (149
°
F)
Maximum altitude
3.0 km (10,000 ft)
4.6 km (15,000 ft)
Switch Model
Maximum Advanced Services Modules
E5406 zl
4
E5412 zl
4
E8206 zl
2
E8212 zl
4
Содержание J9666A
Страница 1: ...HP Advanced Services zl Module Quick Start Guide with Microsoft Windows Server 2008 R2 ...
Страница 11: ...1 7 Hardware Installation Environmental Specifications Figure 1 3 HP E5412 zl chassis module slots ...
Страница 12: ...1 8 Hardware Installation Environmental Specifications ...
Страница 16: ...2 4 Getting Started Next Steps ...
Страница 32: ...C 8 Hardware Components Replacing Field Replaceable Units FRUs ...
Страница 39: ...center Connection Manager Controller Management and Configuration ...