Switch Ports and Network Cables
This appendix includes switch connector information and network cable
information for cables that should be used with the Series 2700 Switches,
including minimum pin-out information and specifications for twisted-pair
cables.
N o t e
Incorrectly wired cabling is the most common cause of problems for LAN
communications. HP recommends that you work with a qualified LAN cable
installer for assistance with your cabling requirements.
Switch Ports
The RJ-45 10/100/1000Base-T ports on the switch accept 100-ohm differential
unshielded and shielded twisted-pair cable with RJ-45 connectors as
described next.
Twisted-Pair Cables
10 Mbps Operation
Category 3, 4, or 5 100-ohm differential unshielded twisted-
pair (UTP) or shielded twisted-pair (STP) cable, complying
with IEEE 802.3 Type 10Base-T specifications, fitted with
RJ-45 connectors.
100 Mbps Operation
Category 5 100-ohm differential UTP or STP cable,
complying with IEEE 802.3u 100Base-TX specifications,
fitted with RJ-45 connectors.
1000 Mbps Operation
Category 5 100-ohm differential 4-pair UTP or STP cable,
complying with IEEE 802.3ab 1000Base-T specifications,
fitted with RJ-45 connectors—Category 5E or better is
recommended.
(please see “Note on 1000Base-T Cable Requirements”, on
page B-2)
z3.book Page 1 Friday, November 1, 2002 5:40 PM
Содержание J4897A
Страница 1: ...hp procurve series 2700 switches installation guide www hp com go hpprocurve ...
Страница 2: ......
Страница 3: ...HP Procurve Series 2700 Switches Installation Guide z3 book Page i Friday November 1 2002 5 40 PM ...
Страница 8: ...z3 book Page vi Friday November 1 2002 5 40 PM ...
Страница 16: ...z3 book Page 8 Friday November 1 2002 5 40 PM ...
Страница 36: ...z3 book Page 6 Friday November 1 2002 5 40 PM ...
Страница 59: ......