![HP J3109A Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/hp/j3109a/j3109a_installation-manual_165916008.webp)
iv
HP AdvanceStack Switch 10Base-FL Module
Operating Requirements and Limitations
■
Required cable type is 62.5/125 µm fiber-optic cable with ST connectors.
■
Maximum fiber cable length is 2 kilometers.
N o t e
The 10Base-FL Module is a “low power” module. You can install any of the
following combinations of low- and high-power modules in the Switch 2000:
•
Up to six low-power modules
•
Up to five low-power modules and one high-power module
•
Up to four low-power modules and two high-power modules
Installing more than two “high-power” modules in the Switch 2000 is not
supported.
Software Prerequisite:
To use the 10Base-FL Module in the Switch 2000,
the switch must be running software version A.02.01 or later. (Refer to step 1
under “Overview” on page 1.)
Standards Adherence:
The J3109A 10Base-FL Module complies with the
IEEE 802.3j standard.