![HP J3109A Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/hp/j3109a/j3109a_installation-manual_165916019.webp)
9
Installing the 10Base-FL Module in an Unused Slot
Slot and Port LED Behavior
LED
Pattern
Slot Fault
(for the slot in which
you are installing the
module)
1. FLASHING RAPIDLY if the module is not properly
seated
2. ON for less than 1 second after the module has been
properly seated
3. OFF during normal switching operation
4. Flashing slowly if there is a self-test failure.
Check the switch event log through the console interface
for more information.
Note:
If the Fault LED for the module slot continues flashing
rapidly, the module may not be completely seated in the slot.
Ensure that the handles on the module are fully in the “closed”
position and the screws in the handles are tightened.
If the module slot Fault LED continues flashing, unscrew the
screws, open the handles, remove the module, and re-install it.
If the Fault LED continues flashing, remove the module and
contact your HP-authorized LAN dealer or HP networking
support representative.
If a module is not installed properly, and the module slot Fault LED
continues rapid flashing, other modules in the switch will
continue to forward packets normally, but other switch functions
will be suspended until the module is removed or properly
installed.
Self-test
(for the Switch 2000)
1. ON for up to 40 seconds after the module has been
properly seated
2. OFF during normal switching operation
3. FLASHING simultaneously with slot Fault LED if the slot
has failed self-test. Check the event log by selecting “Event
Log” from the switch’s console in the Main Menu.