Chapter 4
Removing and Replacing Components
Removing and Replacing the I/O Baseboard
70
CAUTION
When plugging the SCSI cables, note the labeling on the SCSI A and SCSI B channel
cables. You must match each cable with its appropriate socket on the SCSI HBA. If
the cables are mismatched your server may not reboot. Both cables and sockets are
clearly marked with the correct channel.
Step 6.
Plug in the internal SCSI cable(s) to the HBA board in PCI slot 1.
Step 7.
Replace the top cover. See “Replacing the Top Cover” on page 44
Step 8.
If rack mounted, slide the HP server into the rack until it stops. See “Inserting the Server into the
Rack” on page 39.
Step 9.
Power up and boot to EFI.
Step 10.
Respond
YES
to prompts regarding copying information onto the new I/O baseboard.
Step 11.
Enter SERVICE mode.
Shell> sysmode service
Current System Mode: ADMIN
You are now in SERVICE mode.
Step 12.
Use the 'sysset' command to enter the product data:
Shell> sysset prodname "server rx4640"
Step 13.
Use the
sysset
command to verify all values are set:
Shell> sysset
System Information:
Manufacturer: hp
Product Name: server rx4640
Product Number: A6961A
Secondary Product Number is Identical
Serial number: SGH43442VB
Secondary Serial Number is Identical
UUID: 3C33C58E-2E5A-11D8-A33B-4188C0AEFAE2 (Valid)
Secondary UUID is Identical
Product ID: 0x305
Step 14.
Use the EFI
date
and
time
commands to set the correct local date and time.
Step 15.
Boot the server and resume normal operation.