Installation Manual
CA294-03070 rev 00
page 16 of 153
Heading
Step
Reference
Procedure
Notes and
check
aa. Click
Setup
.
The Setup OD of 100% Spec
Values window opens.
bb. Enter the optical density values
noted in step l above in the
appropriate color fields.
cc. Click
OK
.
A warning may appear. Click
OK
to close the warning.
dd. In the wizard, complete the wizard
steps.
Make sure that the color
calibration is completed
successfully.
ee. From the
Diagnostics
menu,
click
Writing Head
.
The Writing Head window opens.
ff. Click the
Laser Power
tab.
gg. Check that the Laser Power
values do not approach the upper
or lower limits (30 to 1).
If the values are at either
extremity, perform the Machine
LUT Calibration wizard from
Adjustments
>
Machine LUT
Calibration
.
11.
If necessary, perform the Machine
LUT using 180 lpi.
Testing during normal operation on page
145.
73.
CATP on page 145
Perform CATP test procedure:
Printing CATP test on page 147.
Check CATP against CATP specification
checklist on page 147.
Complete the
installation on page
150
Complete installation as detailed on page
150.