Output Listings and Error Handling
eld Manual—527255-009
6-114
Error Messages
specified for the process subtype. The new file that
eld
creates will have the process
subtype that you specified this time, not the value that was in the previous file.
Effect.
Warning (
eld
produces an output file, but it might not be what you intended).
Recovery.
Assuming you gave the file the wrong process subtype before, or had
some other reason to change it now, no action is required.
Cause.
You gave a
-r
option, and exactly one input object file, to tell
eld
to create
another object file that could be used as
eld
input again, and you also gave the
-set
floattype option
, to tell
eld
which floating point type to indicate in the output
object file, and it was different from what the input file contained.
Effect.
Information (This is not indicative of a problem).
Recovery.
Assuming you gave the file the wrong floating point type before, or had
some other reason to change it now, no action is required.
Cause.
You used the
-set user_buffers
option, which affects how a program
performs I/O, and you also used the
-r
option, to tell
eld
to build another object file
that can be used as linker input, rather than a program.
Effect.
Fatal error (
eld
immediately stops without creating an output file).
Recovery.
If your intention is to create a program, then don’t specify the
-r
option. If
your intention is to use the
-r
option to create a new object file that can be used as
eld
input, then don’t specify the
-set user_buffers
option.
Cause.
While reading the private DLL registry that was specified for this link in the
-check_registry
or
-update_registry
option,
eld
ran off the end of the file
when it was expecting to see the name of a DLL after the
-range
keyword.
Presumably, the format of the file is bad because it was incorrectly edited by hand.
Effect.
Fatal error (
eld
immediately stops without creating an output file).
Recovery.
Fix the format of the file, as explained elsewhere in this manual.
1612 The floating point type of the input file, which was
<string>, has been changed to <string>.
1613 The -set user_buffers option is not allowed with the -r
option.
1614 DLL registry, line <number>: end of file in the middle
of a -range command.
Содержание eld
Страница 4: ......
Страница 8: ...Contents eld Manual 527255 009 iv ...
Страница 12: ...What s New in This Manual eld Manual 527255 009 viii Changes to the 527255 005 Manual ...
Страница 34: ...Introduction to eld eld Manual 527255 009 1 14 Example of Use ...
Страница 54: ...eld Input and Output eld Manual 527255 009 2 20 Using Archives ...
Страница 98: ...Other eld Processing eld Manual 527255 009 4 20 Merging Source RTDUs ...
Страница 242: ...Output Listings and Error Handling eld Manual 527255 009 6 132 Glossary of Errors ...