Output Listings and Error Handling
eld Manual—527255-009
6-67
Error Messages
Cause.
You gave the -unres_symbols option on the command line. The next token on
the command line must be one of the possible keyword parameters that you can give
with this option, but
eld
didn’t recognize the parameter specified. (The possibilities
are “error”, “warn”, and “ignore”.)
Effect.
Fatal error (
eld
immediately stops without creating an output file).
Recovery.
Fix the spelling of the parameter. Case doesn’t matter, but other than that
it must be exactly as shown in the manual
.
Cause.
You gave the -temp_r option more than once on the command line. This
option tells the name of a file to use as a temporary file while creating a private DLL
registry. You can give this option more than once, but only if you specify the same
filename.
Effect.
Fatal error (
eld
immediately stops without creating an output file).
Recovery.
If you want to specify this option, only specify one filename.
Cause.
The option mentioned in the message takes a numerical parameter. You gave
this option more than once on the command line, with different numbers specified as
the parameter value. You can give the option more than once, but the numerical value
that you specify must be the same each time.
Effect.
Fatal error (
eld
immediately stops without creating an output file).
Recovery.
If you want to specify this option, decide which value you want to specify,
and only specify that value.
Cause.
You gave the -update_registry option more than once on the command line,
with different names given for the parameter, to tell the name of the private DLL
registry file. You can give the option more than once, but the filename that you specify
must be the same each time.
Effect.
Fatal error (
eld
immediately stops without creating an output file).
1373 Unrecognized parameter to the -unres_symbols option.
1374 Multiple specifications of the -temp_r option with
different filenames.
1375 Multiple specifications of the <option name> option with
different values.
1376 Multiple specifications of the -update_registry option
with different values.
Содержание eld
Страница 4: ......
Страница 8: ...Contents eld Manual 527255 009 iv ...
Страница 12: ...What s New in This Manual eld Manual 527255 009 viii Changes to the 527255 005 Manual ...
Страница 34: ...Introduction to eld eld Manual 527255 009 1 14 Example of Use ...
Страница 54: ...eld Input and Output eld Manual 527255 009 2 20 Using Archives ...
Страница 98: ...Other eld Processing eld Manual 527255 009 4 20 Merging Source RTDUs ...
Страница 242: ...Output Listings and Error Handling eld Manual 527255 009 6 132 Glossary of Errors ...