162
HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
Cache Has Been Disabled Because ADG Enabler Dongle is Broken or Missing
Description: The cache has been disabled because RAID ADG volume is
configured but the ADG Enabler Dongle is broken or missing.
Action: Check the ADG Enabler Dongle. Replace if needed.
Cache Has Been Disabled; Likely Caused By a Loose Pin on One of the RAM
Chips
Description: Cache has been disabled due to a large number of ECC errors
detected while testing the cache during POST. Likely caused by a loose pin on
one of the RAM chips.
Action: Try reseating the cache to the controller. If that does not work, replace
the cache.
Configuration Signature is Zero
Description: ADU detected that NVRAM contains a configuration signature of
zero. Old versions of the server setup utility could cause this.
Action: Run the latest version of server setup utility to configure the controller
and NVRAM.
Configuration Signature Mismatch
Description: Array accelerator board is configured for a different array
controller board. Configuration signature on array accelerator board does not
match the one stored on the array controller board.
Action: To recognize the array accelerator board, run ACU.
Содержание DL360 - ProLiant - Photon
Страница 24: ......
Страница 30: ...30 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 42: ......
Страница 94: ...94 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 97: ...Troubleshooting 97 ...
Страница 99: ...Troubleshooting 99 ...
Страница 101: ...Troubleshooting 101 ...
Страница 104: ...104 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 222: ......
Страница 236: ......
Страница 241: ...Acronyms and Abbreviations 241 VHDCI very high density cable interconnect WOL Wake on LAN ...
Страница 242: ......