Troubleshooting
157
Accelerator Error Log
Description: List of the last 32 parity errors on transfers to or from the memory
on the array accelerator board. Displays starting memory address, transfer count,
and operation (read and write).
Action: If many parity errors are listed, you may need to replace the array
accelerator board.
Accelerator Parity Read Errors: X
Description: Number of times that read memory parity errors were detected
during transfers from memory on array accelerator board.
Action: If many parity errors occurred, you may need to replace the array
accelerator board.
Accelerator Parity Write Errors: X
Description: Number of times that write memory parity errors were detected
during transfers to memory on the array accelerator board.
Action: If many parity errors occurred, you may need to replace the array
accelerator board.
Accelerator Status: Cache was Automatically Configured During Last Controller
Reset
Description: Cache board was replaced with one of a different size.
Action: No action is required.
Accelerator Status: Data in the Cache was Lost...
...due to some reason other than the battery being discharged.
Содержание DL360 - ProLiant - Photon
Страница 24: ......
Страница 30: ...30 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 42: ......
Страница 94: ...94 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 97: ...Troubleshooting 97 ...
Страница 99: ...Troubleshooting 99 ...
Страница 101: ...Troubleshooting 101 ...
Страница 104: ...104 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 222: ......
Страница 236: ......
Страница 241: ...Acronyms and Abbreviations 241 VHDCI very high density cable interconnect WOL Wake on LAN ...
Страница 242: ......