![HP CL2100 G3 407S Скачать руководство пользователя страница 104](http://html.mh-extra.com/html/hp/cl2100-g3-407s/cl2100-g3-407s_user-and-maintenance-manual_164271104.webp)
Warnings & Safety/
Warnungen & Sicherheit/
Предупреждения
и
безопасность
104
CAUTION:
Laser Drive Equipment
The optical transceiver module in this server is a laser Class 1 product.
Ambient Operation
This equipment cannot be operated above an ambient operation temperature of 40 degrees
centigrade.
Equipment Location
This equipment can only be accessed by SERVICE PERSONNEL or by USERS who have been
instructed about the reasons for the restrictions applied to the location. Access is through the use
of a TOOL or lock and key, or other means of security, and is controlled by the authority
responsible for the location.
CAUTION:
Do not connect the server to any other type of power system to reduce the
risk of electric shock.
WARNING:
This server is suitable for use on an IT power distribution system whose
maximum phase-to-phase voltage is 240 V under any distribution fault condition.
Electrical current from power, telephone, and communication cables is hazardous. To
avoid a shock hazard:
Do not connect or disconnect any cables or perform installation, maintenance, or
reconfiguration of this product during an electrical storm.
Connect all power cords to a properly wired and grounded electrical outlet.
Connect to properly wired outlets any equipment that will be attached to this product.
When possible, use one hand only to connect or disconnect signal cables.
Never turn on any equipment when there is evidence of fire, water, or structural damage.
Disconnect the attached power cords, telecommunications systems, networks, and modems
before you open the device covers, unless instructed otherwise in the installation and
configuration procedures.
Connect and disconnect cables as described in the following table when installing, moving,
or opening covers on this product or attached devices.
To Connect:
To Disconnect:
1
Turn everything OFF.
2
First, attach all cables to devices.
3
Attach signal cables to connectors.
4
Attach power cords to outlet.
5
Turn device ON.
1
Turn everything OFF.
2
First, remove power cords from outlet.
3
Remove signal cables from
connectors.
4
Remove all cables from devices.
CAUTION:
The power control button on the device and the power switch on the
power supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current from the
device, ensure that all power cords are disconnected from the power source.