1.
From the Profiles page, select the profile to be verified.
2.
Click
Edit
. The Edit Profile information appears below the profile table.
3.
In the Profile Information table, click the question mark icon.
4.
If EFI partition data is present in the profile, the EFI icon appears as well as the option to clean up the
data.
5.
(Optional) To clean up the partition data, check the
Remove EFI partition attached to profile
checkbox
and click
OK
. The
Virtual Connect Enterprise Manager is executing the request
message appears.
6.
Click
OK
to go to the Jobs page and monitor job progress.
Assigning a profile
VCEM detects the presence of logical server managers or upper level managers. When performing this task,
a prompt dialog message appears and explains the impact of performing that task from outside the logical
server manager or upper level manager. The following message appears:
IMPORTANT: VCEM has detected you may be using other products, such as HP Insight
Dynamics – VSE. Assigning this Server Profile can make it inconsistent with
the upper level manager. It is recommended to use the upper level manager to
assign this Server Profile. Type YES to proceed with this operation.
To proceed, you must type
YES
, and then click
OK
. VCEM does not proceed if you cut and paste YES into
the field.
1.
From the Profiles page, filter the profiles by the VC Domain Group that has the unassigned profiles.
2.
In the profiles list, click the
Assign
link, or select a profile to assign, and then click
Assign
. The Profile
Assignment page appears.
3.
Select an available server bay to which the profile is assigned.
4.
Click
OK
. The
Virtual Connect Enterprise Manager is executing the request
message
appears.
5.
Click
OK
to go to the Jobs page and monitor job progress.
Unassigning a profile
VCEM detects the presence of logical server managers or upper level managers. When performing this task,
a prompt dialog message appears and explains the impact of performing that task from outside the logical
server manager or upper level manager. The following message appears.
IMPORTANT: VCEM has detected you may be using other products, such as HP Insight
Dynamics – VSE. Unassigning this Server Profile can make it inconsistent with
the upper level manager. It is recommended to use the upper level manager to
Unassign this Server Profile. Type YES to proceed with this operation.
To proceed, you must type
YES
, and then click
OK
. VCEM does not proceed if you cut and paste YES into
the field.
1.
From the Profiles page, select the assigned profile to unassign.
2.
Click
Unassign
. You are prompted to confirm the unassignment.
3.
Click
OK
. The
Virtual Connect Enterprise Manager is executing the request
message
appears.
4.
Click
OK
to go to the Jobs page and monitor job progress.
Copying and assigning a profile to a bay
1.
From the Profiles page, select the profile that must be copied and assigned.
2.
Click
Copy
.
3.
Enter a unique name for the new profile.
4.
Select an available bay to which the new profile is assigned.
5.
Set the port information.
6.
Enter a unique name for the new profile.
Profiles
57
Содержание BL680c - ProLiant - G5
Страница 8: ...8 ...
Страница 10: ...10 ...
Страница 16: ...16 ...
Страница 19: ...VCEM home page The following screenshot shows the VCEM home page Figure 2 1 VCEM home page VCEM home page 19 ...
Страница 20: ...20 ...
Страница 50: ...50 ...
Страница 74: ...74 ...
Страница 76: ...76 ...
Страница 80: ...80 ...
Страница 82: ...82 ...
Страница 86: ...86 ...
Страница 104: ...104 ...
Страница 108: ...108 ...