System memory 273
Table 12-29
Provider Indication Common Properties
Property name
Property implementation
SystemFirmwareVersion
Array of firmware version of the computer system
generating the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
The following tables describe the SMX Memory Provider indications that are implemented for server
platforms where available:
Table 12-30
SMX_MemoryIndication: Memory Module Predictive Failure
Property name
Property implementation
CIM_Indication
PercieivedSeverity
5 (Major)
CIM_AlertIndication
Description
A memory module has failed or is predicted to fail.
(
MemoryModuleCaption
) where
MemoryModuleCaption
is the
SMX_MemoryModule.Caption for the failing memory
module
AlertingManagedElement
WBEM Path of SMX_MemoryModule instance
representing the memory module
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
ProviderName
SMXMemory
RecommendedActions
Check the memory configuration and replace memory
as necessary.
HP_AlertIndication
Summary
Memory module has failed or is predicted to fail
EventCategory
3 (Memory)
ProbableCause
1 (Other)
ProbableCauseDescription
Memory Module Failed or Predicted to Fail