Smart Array 137
4-4-21
HP_DeviceIndication: Enclosure Power Supply
status changed to Redundant Degraded
Table 4-106
HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name
Property implementation
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation
Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
4-4-22
HP_DeviceIndication: Enclosure Temperature
sensor status changed to OK
Table 4-107
HP_DeviceIndication: Enclosure Temperature sensor status changed to OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Temperature sensor status
changed from Non-OK to a status of OK.
AlertingMangedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)