Smart Array 102
4-4-7
SMX_SAStorageVolumeIndication: Logical Drive
Status Changed to Degraded
Table 4-92
SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded
Property name
Property implementation
EventID
103
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array
RecommendedActions
Check status of physical drives. Degraded status may
be caused by failed or missing physical drives, or a
data recovery operation on one or more physical
drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Logical drive status in degraded state
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
Logical State Changed to Degraded
NetworkAddresses
Contains a list of all the IP addresses of the computer
system generating the indication
OSType
SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion
2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication