System Temperature Sensor 244
Table 11-7
HP_AlertIndication_: Temperature Sensor Threshold Exceeded
Property name
Property implementation
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
VariableNames
Contains the temperature sensor threshold property
name that sets a value:
UpperThresholdNonCritical
UpperThresholdCritical
UpperThresholdFatal
VariableTypes
9 (sint32)
VariableValues
SMX_NumericSensor UpperThresholdNonCritical,
UpperThresholdCritical, or UpperThresholdFatal
property value that is set for the temperature sensor
detecting the exceeded threshold
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Table 11-8
HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication