HP Insight Management WBEM Providers for 
HP integrated VMware ESXi 

Data Sheet 

 

 

Part number 574748-002 
Second Edition December 2009 
 

 

Содержание BL460c - ProLiant - G5

Страница 1: ...HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet Part number 574748 002 Second Edition December 2009 ...

Страница 2: ...HP will not be liable for technical or editorial errors or omissions contained herein Confidential computer software Valid license from HP required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial items are licensed to the U S Government under vendors standard commercial license Window...

Страница 3: ...EthernetRemoteServiceAccessPoint 25 2 3 16 SMX_EthernetRemoteAccessAvailableToIPEndpoint 26 2 3 17 SMX_EthernetRemoteServiceHostedAccessPoint 27 2 3 18 SMX_EthernetStatistics 27 2 3 19 SMX_EthernetPortStatisticalData 28 2 3 20 SMX_EthernetPortControllerSoftwareIdentity 29 2 3 21 SMX_EthernetPortControllerFirmwareIdentity 29 2 3 22 SMX_EthernetElementSoftwareIdentity 30 2 3 23 SMX_EthernetElementFi...

Страница 4: ...9 4 3 28 SMX_SADiskDriveLocation 70 4 3 29 SMX_SAArrayControllerLocation 71 4 3 30 SMX_SAStorageCapabilities 72 4 3 31 SMX_SAProduct 73 4 3 32 SMX_SAStorageEnclosureLocation 74 4 3 33 SMX_SAArraySystemRedundancySet Association 74 4 3 34 SMX_SAStorageVolumeStorageSetting Association 75 4 3 35 SMX_SAPrimordialPoolStorageCapabilities Association 75 4 3 36 SMX_SAStoragePoolStorageCapabilities Associat...

Страница 5: ...ciation 84 4 3 79 SMX_SAArrayControllerPhysicalPackageArrayControllerLocation Association 85 4 3 80 SMX_SAPhysicalPackageArraySystemLocation Association 85 4 3 81 SMX_SADriveCageDriveCageLocation Association 85 4 3 82 SMX_SADiskPhysicalPackageDiskDriveLocation Association 85 4 3 83 SMX_SASCSIProtocolEndpointSCSIProtocolController Association 86 4 3 84 SMX_SAStorageEnclosureEnclosureLocation Associ...

Страница 6: ...ons 156 6 3 1 SMX_ComputerSystem 156 6 3 2 SMX_ComputerSystemChassis 161 6 3 3 SMX_ComputerSystemPackage 162 6 3 4 SMX_OperatingSystem 162 6 3 5 SMX_RunningOS 163 6 3 6 SMX_InstalledOS 164 6 3 7 SMX_BaseServerECTP 164 6 3 8 SMX_SMXSoftwareIdentity 165 6 3 9 SMX_SMXInstalledSoftwareIdentity 166 6 3 10 SMX_SystemFirmware 166 6 3 11 SMX_SystemInstalledFirmwareIdentity 167 6 3 12 SMX_SystemElementFirm...

Страница 7: ...MX_FanElementLocation 201 8 3 11 SMX_FanModule 201 8 3 12 SMX_SystemPhysicalFan 202 8 3 13 SMX_RealizesFan 203 8 3 14 SMX_FanSlot 203 8 3 15 SMX_SystemFanSlot 204 8 3 16 SMX_FanInSlot 204 8 4 Supported indications 204 8 4 1 Provider Indication Common Properties 204 8 4 2 HP_DeviceIndication Fan Removed 205 8 4 3 HP_DeviceIndication Fan Inserted 206 8 4 4 HP_SensorHardwareIndication Fan Failed 207 ...

Страница 8: ... Supply Redundancy Failed 229 9 4 10 HP_DeviceIndication Power Supply Redundancy Restored 230 10 SMX Profile registration provider 232 10 1 Overview 232 10 2 Namespaces 232 10 3 Class implementations 232 10 3 1 SMX_RegisteredProfile 232 10 3 2 SMX_ExtendsProfile 236 10 3 3 SMX_ReferencedProfile 236 10 3 4 SMX_PRPBaseServerECTP 236 10 4 Supported indications 237 11 System Temperature Sensor 238 11 ...

Страница 9: ...13 3 5 SMX_BladeEnclosureGroupHostedCollection 280 13 3 6 CIM_SoftwareIdentity 280 13 3 7 CIM_ElementSoftwareIdentity 281 13 3 8 SMX_BladeEnclosureInstalledFWIdentity 282 13 3 9 SMX_BladeCSLocation 282 13 3 10 SMX_BladeCSElementLocation 283 13 4 Supported indications 283 14 FC HBA 284 14 1 Overview 284 14 2 Namespaces 284 14 3 Class implementations 284 14 3 1 SMX_FCHBAComputerSystem 284 14 3 2 SMX...

Страница 10: ...colController 300 14 3 30 SMX_FCHBASCSIProtocolEndpoint 301 14 3 31 SMX_FCHBAComputerSystemSCSIProtocolController 301 14 3 32 SMX_FCHBAFCPortSCSIProtocolEndpoint 302 14 3 33 SMX_FCHBASCSIProtocolControllerFCPort 302 14 3 34 SMX_FCHBASystemServiceAccessPoint 302 14 3 35 SMX_FCHBAConcreteIdentity 303 15 Management Processor Lite 304 15 1 Overview 304 15 2 Namespaces 304 15 3 Class implementations 30...

Страница 11: ...oviders supply system management data through HP integrated VMware ESXi framework for HP ProLiant server platforms and options These providers implement the profiles and data described in this document Use of the providers requires HP integrated VMware ESXi ...

Страница 12: ... local host OS CIMOM on each individual monitored system and describe the ethernet ports associated controllers and logical ethernet interfaces that are available in the system These classes do not describe Management Processor of iLO related information that information is provided via the MPLite provider SMX_EthernetPort SMX_EthernetDevice SMX_EthernetLANEndpoint SMX_EthernetLANHostedAccessPoint...

Страница 13: ...thernetPort Property name Property implementation CIM_ManagedElement ElementName Same as Caption Caption Text describing this port as advertised from PCI config header information For Example Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express rev 21 Description A description of the instance with unique port number for each port on a particular controller for example Ethernet port...

Страница 14: ...stem CIM_LogicalPort MaxSpeed Current bandwith in bits per second If port has link value is 0 otherwise CIM_NetworkPort AutoSense Boolean that is true if Ethernet Port can automatically determine speed of comm charateristics of the network FullDuplex Boolean that is true if operating in FullDuplex mode LinkTechnology 2 Ethernet Permanent Address The logical MAC address of a the Ethernet Port in th...

Страница 15: ...of 16 bit unsiged integers advertising the capabilities of the EthernetPort 0 Unknown 1 Other 2 AlertOnLan 3 WakeOnLan CapabilityDescriptions Capability Descriptions 0 per Capabilities 0 Text descriptions for the Capabilities array above Examples Unknown Other Alert On LAN Wake On LAN EnabledCapabilities Specifies which of the Ethernet Ports capabilities are enabled NetworkAddresses Array of MAC a...

Страница 16: ... communication endpoint which when its associate interface is connected to a LAN might send and receive data frame Table 2 4 Class SMX_EthernetLANEndpoint Property name Property implementation CIM_ManagedElement Caption LAN Endpoint info for OS Exposed Ethernet Port informatiom For example LAN Endpoint instanceNum for 82546GB Gigabit Ethernet Controller port portNumber CIM_ManagedSystemElement Hea...

Страница 17: ...r port portNumber NameFormat HPQ SMX_EthernetLANEndpoint unique_instance_nu m ProtocolIFType 6 Ethernet CSMA CD CIM_LANEndpoint MACAddress Text representing the principal unicast address used in communication with the LANEndpoint Twelve hexadecimal digits For Example 010203040506 HP_EthernetLANEndpoint 2 3 4 SMX_EthernetLANHostedAccessPoint SMX_EthernetLANHostedAccessPoint implements the class HP_...

Страница 18: ... logical device corresponding to a hardware Ethernet network controller Table 2 7 Class SMX_EthernetPortController Property name Property implementation CIM_ManagedElement Caption A description of the class for example Ethernet Controller controller id Description A description of the class for example Ethernet Controller controller id ElementName A description of the class for example Ethernet Co...

Страница 19: ...hernet Ports Table 2 8 Class SMX_EthernetPortControllerEthernetPort Property name Property implementation CIM_Dependency CIM_DeviceConnection CIM_ControlledBy HP_PortControllerEthernetPort Antecedent ref SMX_EthernetPortController Dependent ref SMX_EthernetPort 2 3 8 SMX_EthernetPortControllerPhysicalPackage SMX_EthernetPortControllerPhysicalPackage implements the class HP_EthernetPortControllerPh...

Страница 20: ...e BCM5753M Gigabit Ethernet PCI Express rev 21 ElementName Ethernet Controller Package Manufacturer Text representng vendor info from PCI config space HP Intel Broadcom and so on Tag HPQ SMX_EthernetPortContollerPhysicalPackage controller_id Version Hardware version of the Package or N A CIM_PhysicalPackage OtherPackageType If PackageType is 1 Other then this text will further descript the package...

Страница 21: ...rty name Property implementation CIM_ManagedElement ElementName Product Name For Example 2 port controller Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express rev 21 CIM_Location Name PCISLOT Embedded Ethernet PhysicalPosition Opaque key Example for a contoller in cabinet 1 bay 2 chassis 3 slot 6 01 02 03 FF FF 06 FF 85 For Embedded Ethernet Controller 2 in this system FF FF FF FF...

Страница 22: ...ference with LocationInfoDescription array to determine what type of location information is represented 2 3 11 SMX_EthernetControllerPhysicalPackageEthernetControlle rLocation SMX_EthernetControllerPhysicalPackageEthernetControllerLocation implements HP_EthernetControllerPhysicalPackageEthernetControllerLocation and associates SMX_EthernetControllerPhysicalPackage to its logical SMX_EthernetContr...

Страница 23: ...ated ElementName Description For Linux operating System ethernet device name For Example eth1 For ESXi manamgement network logical interface name For example vmk0 ipv4 0 CIM_ManagedSystemElement HealthState Same as associated LAN Endpoint StatusDescriptions StatusDescriptions 0 per OperationalStatus 0 Unknown OK Degraded Error CIM_LogicalElement CIM_EnabledLogicalElement RequestedState 0 Unknown E...

Страница 24: ... advertises a valid IPv6 Address Its used to describe the prefix length of the IPv6Address subnet Experimental Schema PrefixLength Same as IPv6SubnetPrefixLength non experimental schema Name Opaque Key SMX scoped instance name For example HPQ SMX_IPProtocolEndpoint instance_num NameFormat Text describing the method to create a unique name for every IPProtocolEndpoint For example Opaque Key Unique ...

Страница 25: ...FrameType 1 Etherent HP_IPBindsToEthernetLANEndpoint Antecedent ref SMX_EthernetLANEndpoint PartComponet Ref SMX_IPProtocolEndpoint 2 3 14 SMX_EthIPHostedAccessPoint SMX_EthIPHostedAccessPoint implements the class HP_EthIPHostedAccessPoint and associates IP Protocol Endpoints to the Computer System Table 2 15 Class SMX_IPProtocolBingsToEthernetLANEndpoint Property name Property implementation CIM_...

Страница 26: ...ntext 0 Unknown 2 Default Gateway AccessInfo If ProtocolIFType 4095 IPv4 then text value is dot delimited ip address of default gateway otherwise 0 0 0 0 if default gateway is unassigned If ProtocolIFType 4097 or 4098 IPv6 the text value is either a valid IPv6 Address or 128 if default gateway is unassigned InfoFormat 3 IPv4 Address 4 IPv6 Address 2 3 16 SMX_EthernetRemoteAccessAvailableToIPEndpoi...

Страница 27: ...SMX_EthernetRemoteServiceHostedAccessPoint SMX_RemoteServiceHostedAccessPoint implements the class HP_RemoteServiceHostedAccessPoint and associates Remote Service Access Point to the Computer System in a managed system NOTE Currently not implemented on VMware ESXi platform Table 2 18 Class SMX_RemoteServiceHostedAccessPoint Property name Property implementation CIM_Dependency CIM_HostedDependency ...

Страница 28: ...otal number of bytes transmitted PacketsReceived Total number of packets received CIM_EthernetPortStatistics AlignmentErrors See CIM_EthernetPortStatistics mof DeferredTransmissions See CIM_EthernetPortStatistics mof ExcessiveCollisions See CIM_EthernetPortStatistics mof FCSErrors See CIM_EthernetPortStatistics mof InternalMACReceiveErrors See CIM_EthernetPortStatistics mof InternalMACTransmitErro...

Страница 29: ...areidentity Property name Property implementation CIM_ ManagedElement Caption Ethernet Port Controller Driver Description Product Name Device Driver where product name is the product name of the Ethernet Adapter ElementName Ethernet Port Controller Driver CIM_ManagedSystemElement Name DriverFilename CIM_LogaicalElement CIM_SoftwareIdentity ClassificationDescriptions Ethernet Port Controller Driver...

Страница 30: ...onDescriptions Ethernet Port Controller Firmware Classifications 10 firmware InstanceID HPQ SMX_EthernetPortControllerFirmwareIdentity inst anceNum IdentityInfoType CIM SoftwareFamily IdentityInfoValue 0 HPQ PCI Vendor Id DeviceId TargetType PCI Vendor Id Device Id Manufacturer Manufacturer VersionString Firmware Version 2 3 22 SMX_EthernetElementSoftwareIdentity SMX_EthernetElementSoftwareIdentit...

Страница 31: ...t ref SMX_EthernetPortControllerFirmwareIdentity Dependent ref SMX_EthernetPortController CIM_ElementSoftwareIdentity ElementSoftwareStatus ElementSoftwareStatus 0 2 Current ElementSoftwareStatus 1 6 Installed 2 3 24 SMX_EthernetCollection SMX_EthernetCollection implements the class HP_EthernetCollection It represents the collection of all Ethernet Ports Table 2 25 Class SMX_EthernetCollection Pro...

Страница 32: ...y implementation CIM_ MemberOfCollection Collection ref SMX_EthernetCollection Member ref SMX_EthernetPort HP_EthernetMemberOfCollection 2 3 26 SMX_EthernetGroupHostedCollection SMX_EthernetGroupHostedCollection associates the Ethernet Collection to the Computer System Table 2 27 Class SMX_EthernetGroupHostedCollection Property name Property implementation CIM_ Dependency Antecedent ref SMX_Comput...

Страница 33: ...SType On ESX 39 VM On Linux 36 Linux OSVersion The operating system version of the computer system generating the indication in the following format major minor build SystemFirmwareVersion Array of firmware versions of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system gen...

Страница 34: ...as lost connectivity EventCategory 9 Network Device EventSubCategory 11 Ethernet port 12 Ethernet team 13 Ethernet LAN Endpoint ProbableCause 7 Other ProbableCauseDescription Network Interface Lost Connectivity Table 2 30 HP_AlertIndication Network Interface Connectivity Restored Property name Property implementation CIM_Indication PerceivedSevertiy 2 Information CIM_Alertindication Description If...

Страница 35: ...erface Connectivity Restored Property name Property implementation EventCategory 9 Network Device EventSubCategory 11 Ethernet port 12 Ethernet team 13 Ethernet LAN Endpoint ProbableCause 7 Other ProbableCauseDescription Network Interface Connectivity Restored ...

Страница 36: ...specified in the following tables for HP Server platforms where available The classes below describe PCI Device 3 3 1 SMX_PCIDevice SMX_PCIDevice is used to model PCI devices on HP Servers There is an instance of this class for each logical PCI device present in the system Table 3 2 Class SMX_PCIDevice Property name Property implementation CIM_ManagedElement Caption A user friendly description for...

Страница 37: ...s An array of integers that indicates controller capabilities 0 Unknown 1 Other 2 Supports 66MHz 3 Supports User Definable Features 4 Supports Fast Back to Back Transactions 5 PCI X Capable 6 PCI Power Management Supported 7 Message Signaled Interrupts Supported 8 Parity Error Recovery Capable 9 AGP Supported 10 Vital Product Data Supported 11 Provides Slot Identification 12 Hot Swap Supported 13 ...

Страница 38: ...viceID PCI device ID as described in the configuration registers for this PCI device RevisionID Revision ID as described in the configuration registers for this PCI device SubsystemID Subsystem ID as described in the configuration registers for this PCI device SubsystemVendorID Subsystem Vendor ID as described in the configuration registers for this PCI device VendorID Vendor ID as described in th...

Страница 39: ...rd False HP_PCISlotCard 3 3 3 SMX_PCISlot SMX_PCISlot represents PCI device slots on HP Servers There is an instance of this class for each PCI slot in the system whether the slot is occupied or not Table 3 4 Class HP_PCISlot Property name Property implementation CIM_ManagedElement Caption Same as name CIM_ManagedSystemElement Name for all other servers PCI Slot slotNum where n is the physical PCI...

Страница 40: ...ress Mezzanine If in blade Mezzanine slot ConnectorType 43 PCI If this is a 33 MHz PCI slot 80 PCI 66MHZ If this is a 66 MHz PCI slot 98 PCI X If this is a PCI X slot 1 Other If this is a PCI Express slot ConnectorDescription Only initialized if ConnectorType 1 Other PCI Express If this is a PCI Express slot or PCI Express Mezzanine if mezzanine slot in a blade otherwise this property is not set O...

Страница 41: ...y implementation Antecedent References SMX_PCICard Dependent References SMX_PCIDevice 3 3 6 SMX_SystemPCISlot SMX_SystemPCISlot is used to represent an association between SMX_PCISlot and the computer system that contains this PCI slot Table 3 7 Class SMX_SystemPCISlot Property name Property implementation GroupComponent References SMX_ComputerSystemChassis PartComponent References SMX_PCISlot 3 3...

Страница 42: ...n cabinet 1 bay 2 chassis 3 01 02 03 FF FF 06 FF 85 For Slot 2 in a non cellular in this system FF FF FF FF FF 02 FF 85 HP_Location ElementLocationTagDesc 0 Hood Tag ElementLocationTag for HP Integrity Cellular Servers Text representing the controller location Examples Cellular Servers Slot slot_number in Cabinet cab Bay bay Chassis chassis Blade Servers Mezzanine slot_number in Blade blade_num Al...

Страница 43: ...nfornation 0 3 PCI Slot LocationInformation Array of text values representing the location components that describe this Ethernet Controller Physical location LocationInfoDesc 0 per LocationInfornation 0 Cross reference with LocationInfoDescription array to determine what type of location information is represented 3 3 9 SMX_PCISlotElementLocation SMX_PCISlotElementLocation is used to represent an...

Страница 44: ...Smart Array Profile P00121 This provider implements a read only version of the profiles referenced Configuration functionality is not supported by this provider This is in accordance with the SNIA profiles because HP does not advertise and ConfigurationService type classes 4 3 Class implementations The following sections define the supported properties for the Smart Array provider Details for each...

Страница 45: ...s result This provides a short decription to identify who is contributing to non OK status Examples Controller Failure Logical Drive Failure Storage Enclosure Failure Controller Non Failure Problem Physical Drive Non Failure Problem Logical Drive Non Failure Problem Storage Enclosure Non Failure Problem Array is operating properly Array status is unknown CIM_LogicalElement CIM_EnabledLogicalElemen...

Страница 46: ...SAArrayController SMX_SAArrayController implements the HPSA_ArrayController class and represents the controller There is one per HBA and might have multiple controllers Table 4 3 Class SMX_SAArrayController CIM_ComputerSystem Property name Property implementation CIM_ManagedElement ElementName Controller name and location Examples Smart Array in Slot 3 for internal Smart Array Embedded Controller ...

Страница 47: ...ofile CacheBoardPresent See HP Smart Array Profile CacheHasBattery See HP Smart Array Profile AceleratorBackupPowerSource See HP Smart Array Profile CacheParityReadErrors See HP Smart Array Profile CacheParityWriteErrors See HP Smart Array Profile CacheReadPercent See HP Smart Array Profile CacheSerialNumber See HP Smart Array Profile CacheSizeTotal See HP Smart Array Profile CacheState See HP Sma...

Страница 48: ...abled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_LogicalDevice CreationClassName SMX_SAStorageVolume DeviceID Opaque Key SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem Name CIM_StorageExtent ConsumableBlocks 0 BlockSize Block Size in bytes DataRedundancy 1 RAID 0 RAID 5 RAID 6 RAID 50 RAID 60 2 RAID 1 0 DeltaReservation 0 ExtentStatus 0 This indicate...

Страница 49: ...ee HP Smart Array Profile 4 3 4 SMX_SADiskDrive SMX_SADiskDrive implements the HPSA_DiskDrive class and represents the Hard drives connected to Smart Array controllers Table 4 5 Class SMX_SADiskDrive CIM_DiskDrive Property name Property implementation CIM_ManagedElement ElementName Disk location for example Port 1E Box 1 Bay 5 CIM_ManagedSystemElement Name Drive Serial Number OperationalStatus 0 D...

Страница 50: ... NegotiatedDataWidth See HP Smart Array Profile NegotiatedSpeed See HP Smart Array Profile Identify See HP Smart Array Profile 4 3 5 SMX_SAStorageExtent SMX_SAStorageExtent implements the HPSA StorageExtent class represents the consumable storage that is available on a disk drive There is one instance per disk drive Table 4 6 Class SMX_SAStorageExtent CIM_StorageExtent Property name Property imple...

Страница 51: ...ible values 2 None 11 Rebuild Disk drive is currently rebuilding data NumberOfBlocks Total number of blocks on disk drive Primordial Set to True TotalPowerOnHours Total service hours reported disk drive HPSA_StorageExtent 4 3 6 SMX_SADiskDriveFirmware SMX_SADiskDriveFirmware implements the HPSA DiskDriveFirmware class and represents the firmware installed on a disk drive There is one instance per ...

Страница 52: ...ge for the array system as a whole There is one instance per HBA or Storage Subsystem Table 4 8 Class SMX _SAPhysicalPackage CIM_PhysicalPackage Property name Property implementation CIM_ManagedElement ElementName Controller Storage System name and location For example Smart Array in Slot 3 for internal or Smart Array Embedded Controller 7 for embedded controller where 7 is the internal identifier...

Страница 53: ...trollerPhysicalPackage CIM_PhysicalPackage Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example Smart Array in Slot 3 for internal or Smart Array Embedded Controller 7 for embedded controller where 7 is the internal identifier for the embedded controller CIM_ManagedSystemElement Name Controller Serial number CIM_PhysicalElement CreationClass...

Страница 54: ...vendor string Model Drive model string PartNumber N A Not Available in this implementation SerialNumber Drive serial number Tag Opaque Key Version N A Not Available in this implementation CIM_PhysicalPackage HotSwappable TRUE Drive is hot swappable FALSE Drive is not hot swappable RemovalConditions 2 Not Applicable HPSA_ DiskPhysicalPackage 4 3 10 SMX_SAStorageEnclosure SMX_SAStorageEnclosure impl...

Страница 55: ... Opaque key Version N A Not Available in this implementation CIM_PhysicalPackage RemovalConditions 2 Not Applicable CIM_PhysicalFrame CIM_Chassis HP_StorageEnclosure Location See HP Storage Enclosure Profile HPSA_StorageEnclosure 4 3 11 SMX_SAStorageEnclosureProcessor SMX_SAStorageEnclosureProcessor HPSA_StorageEnclosureProcessor class and represents the management processor within a Storage Enclo...

Страница 56: ... Temp Sensor is not detected for internal storage enclosure s of the local controller s for example PCI or Embedded CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_System CreationClassName SMX_SAStorageEnclosureProcessor Name Opaque Key NameFormat Other CIM_ComputerSystem Dedicated 0 2 Other IdentifyingDescrip...

Страница 57: ...ate 12 Not applicable CIM_LogicalDevice CreationClassName SMX_SAPortController DeviceID Controller serial number SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem Name CIM_Controller CIM_PortController ControllerType 1 Other OtherControllerType SCSI Parallel SCSI HBA SAS SATA SAS SATA HBA HPSA_PortController 4 3 13 SMX_SADAPort SMX_SADAPort implements the HPSA_DAPort class and...

Страница 58: ...nabled EnabledState 5 Not applicable RequestedState 12 Not applicable CIM_LogicalDevice CreationClassName SMX_SADAPort DeviceID Opaque key SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem Name CIM_LogicalPort UsageRestriction 2 Front End Only CIM_DAPort HPSA_DAPort 4 3 14 SMX_SAFirmware SMX_SAFirmware implements the HPSA_Firmware class and represents the firmware installed on...

Страница 59: ...roller F W version string HPSA_Firmware 4 3 15 SMX_SAEnclosureFirmware SMX_SAEnclosureFirmware implements the HPSA_EnclosureFirmware class and represents the firmware installed on a Smart Array Enclosure Table 4 16 Class SMX_SAEnclosureFirmware CIM_SoftwareIdentity Property name Property implementation CIM_ManagedElement ElementName TargetType value CIM_ManagedSystemElement Name Storage Enclosure ...

Страница 60: ...l identifier for example Smart Array in Slot 3 Primordial Pool Smart Array Embedded Controller 7 Primordial Pool for embedded controller where 7 is the internal identifier for the embedded controller CIM_ManagedSystemElement CIM_LogicalElement CIM_StoragePool InstanceID Opaque key PoolID Controller serial number Primordial Always set to TRUE RemainingManagedSpace Remaining raw space on controller ...

Страница 61: ...ngManagedSpace Remaining raw space in current pool TotalManagedSpace Total raw space managed by this pool HPSA_StoragePool 4 3 18 SMX_SAMediaAccessStatData SMX_SAMediaAccessStatData implements the HPSA_MediaAccessStatData and represents the Monitoring and Performance data counters on HP Disk Drives Table 4 19 SMX_SAMediaAccessStatData CIM_MediaAccessStatData Property name Property implementation C...

Страница 62: ...mart Array Profile SectorsRead See HP Smart Array Profile SectorsWritten See HP Smart Array Profile SeekCount See HP Smart Array Profile SeekErrors See HP Smart Array Profile ServiceHours See HP Smart Array Profile SpinUpErrors See HP Smart Array Profile RetryRecoveredReadErrors See HP Smart Array Profile RetryRecoveredWriteErrors See HP Smart Array Profile 4 3 19 SMX_SAStorageSetting SMX_SAStorag...

Страница 63: ... DeltaReservationMin 0 NoSinglePointOfFailure FALSE RAID 0 TRUE RAID 1 0 RAID 5 RAID 6 PackageRedundancyGoal 0 RAID 0 1 RAID 1 0 RAID 5 2 RAID 6 RAID 50 RAID 60 PackageRedundancyMax 0 RAID 0 1 RAID 1 0 RAID 5 2 RAID 6 RAID 50 RAID 60 PackageRedundancyMin 0 RAID 0 1 RAID 1 0 RAID 5 2 RAID 6 RAID 50 RAID 60 HPSA_StorageSetting 4 3 20 SMX_SADriveCage SMX_SADriveCage implements the HPSA_DriveCage clas...

Страница 64: ... in this implementation CIM_PhysicalPackage RemovalConditions 2 Not Applicable HP_DriveCage BackplaneSpeed See HP Smart Array Profile DriveBays See HP Smart Array Profile DuplexLocation See HP Smart Array Profile HPSA_DriveCage 4 3 21 SMX_SASCSIProtocolEndpoint SMX_SASCSIProtocolEndpoint implements the HPSA_SCSIProtocolEndpoint class and represents an access point to storage resources Table 4 22 C...

Страница 65: ...nt ConnectionType 1 Other OtherConnectionType PCI Role 0 Unknown 2 Initiator 3 Target 4 Both Initiator and Target HPSA_SCSIProtocolEndpoint 4 3 22 SMX_SASCSIProtocolController SMX_SASCSIProtocolController implements the HPSA_SCSIProtocolController class and represents a view a SCSI resources on the Array Controller Table 4 23 Class SMX_SASCSIProtocolController CIM_SCSIProtocolController Property n...

Страница 66: ...rraySystem SystemName SMX_SAArraySystem Name CIM_ProtocolController MaxUnitsControlled 32 CIM_SCSIProtocolController HPSA_SCSIProtocolController 4 3 23 SMX_SARedundancySet SMX_SARedundancySet implements the HPSA_RedundancySet class and represents controller redundancy if there is more than one controller in a redundant configuration for example MSA500 with two controllers Table 4 24 Class SMX_SARe...

Страница 67: ... Property implementation CIM_ManagedElement ElementName Storage Redundancy Set CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque key CIM_RedundancySet LoadBalanceAlgorithm 2 No Load Balancing MaxNumberSupported 0 MinNumberNeeded 0 RedundancyStatus 2 Fully Redundant 4 Redundancy lost TypeOfSet 0 5 Limited Sparing CIM_StorageRedundancySet HPSA_StorageRedundancySet 4 3 25 SMX_SAStorageSpe...

Страница 68: ... Consolidated status example of HP Smart Array profile for details on how this value is calculated GroupStatusDescriptions 0 Description of failure HPSA_StorageSpecificCollection 4 3 26 SMX_SADriveCageLocation SMX_SADriveCageLocation implements the HPSA_DriveCageLocation class and represents a location string for the drive cage Table 4 27 Class SMX_SADriveCageLocation HP_Location Property name Pro...

Страница 69: ...t Caption Controller name and location Examples Smart Array in Slot 3 for internal Smart Array Embedded Controller 7 for embedded controller where 7 is the internal identifier for the embedded controller Description Controller name and location Examples Smart Array in Slot 3 for internal Smart Array Embedded Controller 7 for embedded controller where 7 is the internal identifier for the embedded c...

Страница 70: ...DriveLocation SMX_SADiskDriveLocation implements the HPSA_DiskDriveLocation class and represents a location string for the disk drive Table 4 29 Class SMX_SADiskDriveLocation HP_Location Property name Property implementation CIM_ManagedElement Caption Controller name Drive Type and Disk Location For example Smart Array E500 Physical Drive Port 1E Box 1 Bay 5 Description Controller name Drive Type ...

Страница 71: ...ernal identifier for the embedded controller Description Controller name and location Examples Smart Array in Slot 3 for internal Smart Array Embedded Controller 7 for embedded controller where 7 is the internal identifier for the embedded controller ElementName Controller name and location Examples Smart Array in Slot 3 for internal Smart Array Embedded Controller 7 for embedded controller where ...

Страница 72: ... For Primodial Pools Controller name and location Examples Smart Array in Slot 3 for internal Smart Array Embedded Contoller 7 for embedded controller where 7 is the internal identifier for the embedded controller For Concrete Pools Controller name and location Array identifier Examples Smart Array in Slot 3 Array 0 for internal Smart Array Embedded Controller 7 Array 0 for embedded controller whe...

Страница 73: ... 2 When number of drives 3 PackageRedundancyMax 0 When number of drives 1 1 When number of drives 2 or 3 2 When number of drives 3 PackageRedundancyMin 0 HPSA_StorageCapabilities 4 3 31 SMX_SAProduct SMX_SAProduct implements the HPSA_Product class and represents the top level marketing information for the Array System Table 4 32 Class SMX_SAProduct CIM_Product Property name Property implementation...

Страница 74: ... and n is the box number Caption Enclosure location Port m Box n where m is the port and n is the box number Description Enclosure location Port m Box n where m is the port and n is the box number Name Key PhysicalPosition Key ElementLocationTag Unknown for Undetermined External for external enclosures Internal for drive cages located within the host chassis ElementLocationTagDesc 19 Box HPSA_Stor...

Страница 75: ...ement SMX_ SAPrimordialPool 4 3 36 SMX_SAStoragePoolStorageCapabilities Association Table 4 37 Class SMX_SAStoragePoolStorageCapabilities CIM_ElementCapabilities Property name Property implementation Capabilities SMX_SAStorageCapabilities ManagedElement SMX_ SAStoragePool 4 3 37 SMX_SAArraySystemStorageEnclosureProcessor Association Table 4 38 Class SMX_SAPrimordialPoolStorageCapabilities CIM_Elem...

Страница 76: ...ame Property implementation GroupComponent SMX_SAArraySystem PartComponent SMX_ SADiskDrive 4 3 41 SMX_SAArraySystemStorageVolume Association Table 4 42 Class SMX_SAArraySystemStorageVolume CIM_SystemDevice Property name Property implementation GroupComponent SMX_SAArraySystem PartComponent SMX_ SAStorageVolume 4 3 42 SMX_SAArraySystemStorageExtent Association Table 4 43 Class SMX_SAArraySystemSto...

Страница 77: ...ss SMX_SAArraySystemPrimordialPool CIM_HostedStoragePool Property name Property implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SAPrimordialPool 4 3 46 SMX_SAArraySystemStoragePool Association Table 4 47 Class SMX_ SAArraySystemStoragePool CIM_HostedStoragePool Property name Property implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SAStoragePool 4 3 47 SMX_SAComp...

Страница 78: ...50 SMX_SAProductPhysicalPackage Association Table 4 51 Class SMX_ SAArraySystemArrayController CIM_ComponentCS Property name Property implementation GroupComponent SMX_SAProduct PartComponent SMX_SAPhysicalPackage 4 3 51 SMX_SAStorageEnclosureDriveCage Association Table 4 52 Class SMX_SAStorageEnclosureDriveCage CIM_Container Property name Property implementation GroupComponent SMX_SAStorageEnclos...

Страница 79: ... SMX_SAStorageEnclosure 4 3 55 SMX_SADriveCageDiskPhysicalPackage Association Table 4 56 Class SMX__SADriveCageDiskPhysicalPackage CIM_Container Property name Property implementation GroupComponent SMX_SADriveCage PartComponent SMX_SADiskPhysicalPackage 4 3 56 SMX_SAStoragePoolStorageExtent Association Table 4 57 Class SMX_SAStoragePoolStorageExtent CIM_ConcreteComponent Property name Property imp...

Страница 80: ...Table 4 60 Class SMX_SAArrayControllerRedundancySet CIM_MemberOfCollection Property name Property implementation Collection SMX_SARedundancySet Member SMX_SAArrayController 4 3 60 SMX_SAStorageRedundancySetStorageExtent Association Table 4 61 Class SMX_SAStorageRedundancySetStorageExtent CIM_MemberOfCollection Property name Property implementation Collection SMX_SAStorageRedundancySet Member SMX_S...

Страница 81: ...FirmwareArraySystem CIM_ElementSoftwareIdentity Property name Property implementation Antecedent SMX_SAFirmware Dependent SMX_SAArraySystem ElementSoftwareStatus ElementSoftwareStatus 0 2 Current ElementSoftwareStatus 1 6 Installed 4 3 64 SMX_SAStorageEnclosureProcessorEnclosureFirmware Association Table 4 65 Class SMX_SAStorageEnclosureProcessorEnclosureFirmware CIM_ElementSoftwareIdentity Proper...

Страница 82: ... SMX_SADiskDrive Dependent SMX_SAStorageExtent 4 3 67 SMX_SADiskPhysicalPackageDiskDrive Association Table 4 68 Class SMX_SADiskPhysicalPackageDiskDrive CIM_Realizes Property name Property implementation Antecedent SMX_SADiskPhysicalPackage Dependent SMX_SADiskDrive 4 3 68 SMX_SAStoragePoolStorageVolume Association Table 4 69 Class SMX_SAStoragePoolStorageVolume CIM_AllocatedFromStoragePool Proper...

Страница 83: ...eRedundancySet Association Table 4 72 Class SASpareExtentStorageRedundancySet CIM_IsSpare Property name Property implementation Antecedent SMX_SAStorageExtent Dependent SMX_SAStorageRedundancySet 4 3 72 SMX_SAStorageExtentStorageVolume Association Table 4 73 Class SMX_SAStorageExtentStorageVolume CIM_BasedOn Property name Property implementation Antecedent SMX_SAStorageExtent Dependent SMX_SAStora...

Страница 84: ...eArraySystem Association Table 4 77 Class SMX_SAPhysicalPackageArraySystem CIM_ComputerSystemPackage Property name Property implementation Antecedent SMX_SAPhysicalPackage Dependent SMX_SAArraySystem 4 3 77 SMX_SAArrayControllerPhysicalPackageArrayController Association Table 4 78 Class SMX_SAArrayControllerPhysicalPackageArrayController CIM_ComputerSystemPackage Property name Property implementat...

Страница 85: ...ocation CIM_PhysicalElementLocation Property name Property implementation Element SMX_SAPhysicalPackage PhysicalLocation SMX_SAArraySystemLocation 4 3 81 SMX_SADriveCageDriveCageLocation Association Table 4 82 Class SMX_SADriveCageDriveCageLocation CIM_PhysicalElementLocation Property name Property implementation Element SMX_SADriveCage PhysicalLocation SMX_SADriveCageLocation 4 3 82 SMX_SADiskPhy...

Страница 86: ...re PhysicalLocation SMX_SAStorageEnclosureLocation 4 4 Supported indications 4 4 1 HP_DeviceIndication Physical Drive Status Changed to OK Table 4 86 HP_DeviceIndication Physical Drive Status Changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 Informational IndicationTime Time of indication CIM_AlertIndicat...

Страница 87: ...e computer system generating the indication in the format major minor build ProviderVersion 2 2 0 0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generati...

Страница 88: ...Physical Disk Serial Number HP_DeviceIndication DeviceModel Physical Disk Model string DeviceControllerLogicalLocation Controller Location For example SmartArray 642 in Slot 2 VariableNames Failure Description DriveInterface LastFailureDescription VariableTypes String 1 uint16 4 VariableValues FailureDescription short description of the failure Drive interface HPSA_DiskDrive DriveInterface LastFai...

Страница 89: ...edActions Check for failed or removed physical drives SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical Drive status is now Error EventCategory 6 Primary Storage ProbableCause 86 Disk Failure ProbableCauseDescription Physical Drive Status Changed to Error Ne...

Страница 90: ...h are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property c...

Страница 91: ...bedded controller where 7 is the internal identifier for the embedded controller 4 4 3 HP_DeviceIndication Physical Drive Status Changed to REBUILDING Table 4 88 HP_DeviceIndication Physical Drive Status Changed to REBUILDING Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 Informational IndicationTime Tim...

Страница 92: ...he indication OSType SMX_OperatingSystem OSType OSVersion The operating system version of the computer system generating the indication in the following format major minor build ProviderVersion 2 2 0 0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID o...

Страница 93: ...W version string HWLogicalLocation Physical Disk Location string for example Port 1E Box 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive Bay Number HWSerialNumber Physical Disk Serial Number VariableNames FailureDescription DriveInterface LastFailureDescription VariableTypes String 1 uint16 4 VariableValues FailureDescription short description of the failure Drive interface HPSA_D...

Страница 94: ...unknown ProviderName HP Smart Array RecommendedActions Replace drive immediately to avoid loss of data SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical Drive status Predictive Failure EventCategory 6 Primary Storage ProbableCause 86 Disk Failure ProbableCau...

Страница 95: ...indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Condition...

Страница 96: ... Array P400 Embedded Controller 7 for embedded controller where 7 is the internal identifier for the embedded controller 4 4 5 HPSA_StorageVolumeIndication Logical Drive Status Changed to OK Table 4 90 HPSA_StorageVolumeIndication Logical Drive Status Changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSev...

Страница 97: ... OSType SMX_OperatingSystem OSType OSVersion The operating system version of the computer system generating the indication in the following format major minor build ProviderVersion 2 2 0 0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the compute...

Страница 98: ...l For example LogicalDrive 1 RAID 1 0 VariableNames FailureDescription VariableTypes String 1 VariableValues FailureDescription short description of the failure HP_DeviceIndication HPSA_StorageVolumeIndication DeviceOperationalStatus Current OperationalStatus values for Storage Volume DeviceOperationalStatus 0 SMX_SAStorageVolume OperationalStatus 0 DeviceOperationalStatus 1 SMX_SAStorageVolume Op...

Страница 99: ...nt time unknown ProviderName HP Smart Array RecommendedActions Check for failed or removed physical drives SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Logical drive status error EventCategory 6 Primary Storage ProbableCause 86 Disk Failure ProbableCauseDescript...

Страница 100: ...dDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect e...

Страница 101: ...evious 0 SMX_SAStorageVolume OperationalStatus 0 DeviceOperationalStatusPrevious 1 SMX_SAStorageVolume OperationalStatus 1 This index is only populated if there is addional Vendor unique status available 4 4 7 SMX_SAStorageVolumeIndication Logical Drive Status Changed to Degraded Table 4 92 SMX_SAStorageVolumeIndication Logical Drive Status Changed to Degraded Property name Property implementation...

Страница 102: ...lertIndication Summary Logical drive status in degraded state EventCategory 6 Primary Storage ProbableCause 86 Disk Failure ProbableCauseDescription Logical State Changed to Degraded NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem OSType OSVersion The operating system version of the computer system generating the ...

Страница 103: ...nditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWHWLogicalLocation Logical drive number and RAID Level for example LogicalDrive 1 Raid 1 0 VariableNames FailureDescription VariableTypes Str...

Страница 104: ...Table 4 93 HP_DeviceIndication Controller Status Changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 Informational IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller status has changed from non OK to OK AlertingMangedElement WBEM Path to SMX_SAArrayControl...

Страница 105: ...sion of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 Enclosure for c Class bla...

Страница 106: ...r Serial Number VariableNames FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes String 1 uint32 5 VariableValues FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController CacheSizeTotal CacheSerialNumber HPSA_ArrayController CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string 4 4 9 HP_DeviceIndication Controller Status Chang...

Страница 107: ...ation Summary Controller status Error EventCategory 6 Primary Storage ProbableCause 24 I O device error ProbableCauseDescription Array Controller Status Changed to Error NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem OSType OSVersion The operating system version of the computer system generating the indication in...

Страница 108: ...tual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller F W version string HWLogicalLocation Array Controller Location string For example Smart Array P600 in Slot 5 Smart Array P400 Embedded Controller 7 for embedded controller where 7 is the internal id...

Страница 109: ...indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of all controllers An array controller may have failed causing this controller to become active SystemName Name of the computer system generating the indication SystemCreationClassname CreationClassName of the computer system generating the indication HP_AlertIndication Summary Controller redundancy state ...

Страница 110: ...ystems Note When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when runnin...

Страница 111: ...ceIndication Controller Redundancy has been lost Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 Warning IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller has detected that redundancy has been lost due to failure or loss of communication with partner controller Ale...

Страница 112: ...r system generating the indication in the format major minor build ProviderVersion 2 2 0 0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the in...

Страница 113: ...Slot 5 Smart Array P400 Embedded Controller 7 for embedded controller where 7 is the internal identifier for the embedded controller HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number VariableNames FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes String 1 uint32 5 VariableValues FailureDescription short description of the failure Cach...

Страница 114: ...commendedActions No Action needed SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Controller Redundancy has been restored EventCategory 6 Primary Storage ProbableCause 1 other ProbableCauseDescription Array Controller Redundancy has been Restored NetworkAddresses C...

Страница 115: ...ureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWF...

Страница 116: ...tery Status Change OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 info IndicationTime Time of indication CIM_AlertIndication Description Array Controller Battery Status has changed to a status of OK AlertingMangedElement WBEM path to the SMX_SAArrayController class AlertingElementFormat 2 CIMObjectPath AlertType ...

Страница 117: ...ware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 Enclosure for c C...

Страница 118: ...ded controller HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number VariableNames FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes String 1 uint32 5 VariableValues FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController CacheSizeTotal CacheSerialNumber HPSA_ArrayController CacheSerialNumber HP_DeviceIndic...

Страница 119: ...become fully charged SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Controller Battery Status set to Not fully charged EventCategory 6 Primary Storage ProbableCause 99 low battery ProbableCauseDescription Controller Battery Status Changed to Not Fully Charged Netw...

Страница 120: ...tem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_Hardwar...

Страница 121: ...ery status changed to Failed Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 major IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller battery status changed to Failed AlertingMangedElement WBEM Path to SMX_SAArrayController class AlertingElementFormat 2 CIMObjectPat...

Страница 122: ...sion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 Enclosur...

Страница 123: ...er for the embedded controller HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number VariableNames FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes String 1 uint32 5 VariableValues FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController CacheSizeTotal CacheSerialNumber HPSA_ArrayController CacheSerialNumbe...

Страница 124: ...lassName of the computer system generating the indication HP_AlertIndication Summary Array Controller Cache Status changed to OK EventCategory 6 Primary Storage ProbableCause 0 ProbableCauseDescription Controller Cache Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem OSType OSVersion Operating ...

Страница 125: ...al system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example Smart Array P600 in Slot 5 Smart Array P400 Embedded Contro...

Страница 126: ...ription Smart Array Controller Cache Status is set to a status of Temporarily Disabled This may be caused by a rebuild or configuration change normal operation will return after background operations have completed AlertingMangedElement WBEM path to the SMX_SAArrayController class AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 10 EventTime Time of the event or time of the i...

Страница 127: ...er of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 Enclosure for c Class blade systems 4 System for all other systems Note When ImpactedDomain is 3 Enclosure th...

Страница 128: ...WSerialNumber Array Controller Serial Number VariableNames FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes String 1 uint32 5 VariableValues FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController CacheSizeTotal CacheSerialNumber HPSA_ArrayController CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string 4 4 18 HP_DeviceIndi...

Страница 129: ...me of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Array Controller Cache Status is Permanently Disabled EventCategory 6 Primary Storage ProbableCause 35 Performance Degraded ProbableCauseDescription Array Controller Cache Status Changed to Permanently Disabled NetworkAddresses Co...

Страница 130: ... RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller ...

Страница 131: ...y implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 Warning IndicationTime Time of indication CIM_AlertIndication Description Storage Enclosure Power Subsystem status has changed to a Non Redundant Status AlertingMangedElement WBEM path of the SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 CIMObjectPath AlertType 5 Devic...

Страница 132: ... system generating the indication in the format major minor build ProviderVersion 2 2 0 0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the ind...

Страница 133: ...SerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string 4 4 20 HP_DeviceIndication Enclosure Power Supply status changed to OK Redundant Table 4 105 HP_DeviceIndication Enclosure Power Supply status changed to OK Redundant Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2...

Страница 134: ... of the computer system generating the indication OSType SMX_OperatingSystem OSType OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion 2 2 0 0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication System...

Страница 135: ...areIndication HWLogicalLocation Enclosure Location string For example Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string 4 4 21 HP_DeviceIndication Enclosure Power Supply status changed to Redundant Degraded Table 4 106 HP_DeviceIndication Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation CIM_I...

Страница 136: ... Storage Power ProbableCause 89 Power supply failure ProbableCauseDescription Redundant Power Supply Degraded NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem OSType OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion 2 2 0 0 SystemFirm...

Страница 137: ... containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string 4 4 22 HP_DeviceIndication Enclosure Temperature sensor status changed to OK Table 4 107 HP_DeviceIndication Enclosure Temperature s...

Страница 138: ...o OK EventCategory 24 Primary Storage Cooling ProbableCause 1 Other ProbableCauseDescription Temperture Status Changed to OK NetworkAddresses Contains a list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication OSType SMX_OperatingSystem OSType OSVersion Operating system version of the computer system generating the indication in the format major minor build Provi...

Страница 139: ...ialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication D...

Страница 140: ...er room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor status changed to Warning Condition EventCategory 24 Primary Storage Cooling ProbableCause 51 Tempe...

Страница 141: ...tionInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running i...

Страница 142: ...ert EventID 309 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SmartArray RecommendedActions Ensure that the system is adequately ventilated Check for proper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClas...

Страница 143: ...the indication ImpactedDomain 3 Enclosure for c Class blade systems 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNum...

Страница 144: ... Alert EventID 304 EventTime Time of the event or time of the indication if event time is unknown ProviderName HP SmartArray RecommendedActions No action required SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Fan Status OK EventCategory 24 Primary Storage Cooling...

Страница 145: ...nclosure for c Class blade systems 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containi...

Страница 146: ...Path AlertType 5 Device Alert EventID 305 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SmartArray RecommendedActions Ensure that the system is adequately ventilated Check for proper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCrea...

Страница 147: ...n SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 Enclosure for c Class blade systems 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUI...

Страница 148: ... Storage Enclosure Fan status changed to a status of Failure An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation AlertingMangedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 306 EventTime Time of the event or time of the indication if event time unkn...

Страница 149: ... the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 Enclosure for c Class blade syst...

Страница 150: ...ailure Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string ...

Страница 151: ...dElement ElementName Controller product name and controller index For example HP Smart Array P400 Controller HPSA1 Note Each Smart Array controller should have a unique controller index Index is an integer that starts from 1 CIM_ManagedSystemElement HealthState 0 Unknown 5 OK 10 Degraded Warning 15 Minor Failure 20 Major Failure 25 Critical Failure 30 Non recoverable Error CIM_LogicalElement CIM_E...

Страница 152: ...rastructure client requires controller name string X matches vmwControllerX reported in HPVC_SAController Name For example Smart Array Controller HPSA1 CIM_ManagedSystemElement Name Smart Array Controller X Firmware CIM_LogicalElement Caption Smart Array Controller X Firmware CIM_SoftwareIdentity InstanceID HPQ Smart Array Controller X Manufacturer HP VersionString Smart Array controller firmware ...

Страница 153: ...ttery BatteryStatus 1 Other 2 Unknown 3 Fully Charged 4 Low 5 Critical 6 Charging 7 Charging and High 8 Charging and Low 9 Charging and Critical 10 Undefined 11 Partially Charged 12 Learning 13 Overcharged VMware_Battery HPVC_SABattery 5 2 4 HPVC_SAStorageExtent HPVC_SAStorageExtent represents physical disk attached to Smart Array controller There is one instance per physical disk Table 5 4 Class ...

Страница 154: ...xtent model serial number For example HPVC_SAStorageExtent HPDG072BB975 3NP2TCCF000098402P95 SystemCreationClassName SMX_ComputerSystem SystemName Server host name CIM_StorageExtent BlockSize Block size in bytes NumberOfBlocks Total number of blocks on disk drive Primordial Set to True VMware_StorageExtent HPVC_SAStorageExtent 5 2 5 HPVC_SAStorageVolume HPVC_SAStorageExtent represents logical volu...

Страница 155: ...on this field should be an empty string For example Logical Volume 1 on HPSA 1 RAID 0 68GB Disk 1 3 4 Interim Recovery CIM_ManagedSystemElement HealthState 0 Unknown 5 OK 10 Degraded Warning 15 Minor Failure 20 Major Failure 25 Critical Failure 30 Non recoverable Error CIM_LogicalElement CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName HPVC_SAStorageVolume DeviceID HPVC_SAStorageVolum...

Страница 156: ...00105 HP WBEM TC 1 1 0 HP Base Server Physical Asset Profile P00114 HP WBEM TC 1 1 0 HP Software Inventory P00127 HP WBEM TC 1 0 1 6 2 Namespaces The provider returns instances in the root hpq namespace 6 3 Class Implementations SMX_ComputerSystem SMX_ComputerSystemChassis SMX_ComputerSystemPackage SMX_OperatingSystem SMX_RunningOS SMX_InstalledOS SMX_BaseServerECTP SMX_SMXSoftwareIdentity SMX_SMX...

Страница 157: ...dSystemElement Status Same as OpertionaStatus 0 OperationalStatus OperationalStatus 0 contains the computer system consolidated status and indicates the worst status of connected subsystems OperationalStatus 0 contains one of the following 0 Unknown 1 Other 2 OK 3 Degraded 6 Error 10 Stopped The status values of the subsystems that make up the overall operational status are contained in Operationa...

Страница 158: ...f the subsystems that make up this computer system have an OperationalStatus value of Error One or more of the subsystems that make up this computer system have an OperationalStatus value of Stopped The status descriptions of the subsytems that make up overall operational status are contained in OperationalStatus 1 n These are set to Unknown OK Degrqaded Error Stopped Predictive Failure HealthStat...

Страница 159: ...stem asset tag string OtherIdentifyingInfo 4 ID_String where ID_String is the computer system physical GUID string OtherIdentifyingInfo 5 ProductID_String where ProductID_String is SMX_ComputerSystemChassis ProductID OtherIdentifyingInfo 6 Target_String where Target_String is an opaque string used by the providers IdentifyingDescriptions IdentifyingDescriptions 0 CIM GUID IdentifyingDescriptions 1...

Страница 160: ...ndicator State of the computer system Unit Identifier UID LED 0 Unknown 2 On 3 Off 5 Alternating SerialNumber The computer system physical serial number string IdentifyingNumber The computer system physical GUID string Model The computer system model string SMX_ComputerSystem Table 6 3 Class Implemented methods for SMX_ComputerSystem Class Method Name Method Implementation SendTestIndication IN Ev...

Страница 161: ...tring SerialNumber Computer system physical serial number UserTracking Computer system asset tag string writable property persistent across reboots Name Computer system product name model string Status OK StatusDescriptions Description of the state of the chassis for example System is functional Description General description of the chassis for example Physical Package for this system Operational...

Страница 162: ...omputerSystemPackage instantiated on a server Table 6 5 Class SMX_ComputerSystemPackage Property name Property implementation CIM_Dependency CIM_SystemPackaging CIM_ComputerSystemPackage PlatformGUID Computer system physical UUID value from SMBIOS HP_ComputerSystemPackage Antecedent ref SMX_ComputerSystemChassis Dependent ref SMX_ComputerSystem SMX_ComputerSystemPackage 6 3 4 SMX_OperatingSystem S...

Страница 163: ...bledDefault 2 Enabled TransitioningToState 12 Not Applicable CIM_OperatingSystem CSName SMX_ComputerSystem Name CSCreationClassName SMX_ComputerSystem CreationClassName Name Output of uname s CreationClassName SMX_OperatingSystem Version Output of uname r OtherTypeDescription On ESX Embedded On Linux NULL OSType On ESX 39 VM On Linux 36 Linux LocalDateTime Current time LastBootUpDateTime Time when...

Страница 164: ...ef CIM_OperatingSystem GroupComponent ref CIM_ComputerSystem SMX_InstalledOS 6 3 7 SMX_BaseServerECTP The SMX_BaseServerECTP class extends the class CIM_ElementConformsToProfile and associates the Base Server registered profile with the HP specific central class that defined the implementation of the profile Table 6 9 Class SMX_BaseServerECTP Property name Property implementation CIM_ElementConfor...

Страница 165: ...sDescriptions 0 Description of the installation status of the software identity for example SMX is installed properly Status OK HealthState 5 OK CIM_LogicalElement CIM_SoftwareIdentity InstanceID Opaque string using HPQ as OrgID for example HPQ SMX_SMXSoftwareIdentity 1 MajorVersion The first numeric value in the VersionString MinorVersion The second numeric value in the VersionString RevisionNumb...

Страница 166: ..._InstalledSoftwareIdentity InstalledSoftware ref CIM_SoftwareIdentity System ref CIM_ComputerSystem SMX_SMXInstalledSoftwareIdentity 6 3 10 SMX_SystemFirmware SMX_SystemFirmware implements the class HP_SoftwareIdentity and describes the firmware found on the server system Table 6 12 Class CIM_SystemFirmware Property name Property implementation CIM_ManagedElement Caption A description of the firmw...

Страница 167: ...sion Manufacturer Hewlett Packard Classifications 11 Bios FCode ClassificationDescriptions System Firmware IdentityInfoValue On ProLiant this will contain HPQ family_code where family_code is the system ROM family code For example HPQ P31 On Integrity this will contain HPQ ElementName IdentityInfoType CIM SoftwareFamily ReleaseDate YYYYMMDD where YYYY is the 4 digit year MM is the 2 digit month an...

Страница 168: ...lementSoftwareStatus The ElementSoftwareStatus array will contain the following if the Antecedent refers to an instance of an Active Firmware ElementSoftwareStatus 0 6 Installed ElementSoftwareStatus 1 2 Current The ElementSoftwareStatus array will contain the following if the Antecedent refers to an instance of a Redundant Firmware ElementSoftwareStatus 0 6 Installed ElementSoftwareStatus 1 4 Fal...

Страница 169: ... 36 Linux OSVersion The operating system version of the computer system generating the indication in the following format major minor build SystemFirmwareVersion Array of firmware versions of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication Syst...

Страница 170: ...robableCauseDescription WBEM Providers Started 6 4 2 HP_DeviceIndication WBEM Providers Informational Test Indication Table 6 17 HP_DeviceIndication WBEM Providers Informational Test Indication Property name Property implementation CIM_Indication PerceivedSeverity 2 Informational CIM_AlertIndication Description This is an information test event AlertType 5 Device Alert EventID 1 ProviderName HP Te...

Страница 171: ...st RecommendedActions No action is recommended HP_AlertIndication Summary Test Event ProbableCause 1 Other ProbableCauseDescription Test Indication 6 4 4 HP_DeviceIndication WBEM Providers Critical Test Indication Table 6 19 HP_DeviceIndication WBEM Providers Critical Test Indication Property name Property implementation CIM_Indication PerceivedSeverity 6 Critical CIM_AlertIndication Description T...

Страница 172: ...cation WBEM Providers Critical Test Indication Table 6 19 HP_DeviceIndication WBEM Providers Critical Test Indication Property name Property implementation Summary Test Event ProbableCause 1 Other ProbableCauseDescription Test Indication ...

Страница 173: ...3 Class Implementations SMX_Processor SMX_ProcessorCapabilities SMX_ProcessorCore SMX_HardwareThread SMX_ProcessorCacheMemory SMX_SystemProcessor SMX_ProcessorElementCapabilities SMX_ProcessorCoreComponent SMX_HWThreadComponent SMX_AssociatedProcessorCacheMemory SMX_ProcessorCollection SMX_HostedProcessorCollection SMX_MemberOfProcessorCollection SMX_ProcessorChip SMX_RealizesProcessor SMX_SystemP...

Страница 174: ...epping 7 ElementName Processor in ProcessorBaord a where a is the slot number Processor in socket b on System Mainboard where b is the socket number Processor in Socket b on ProcessorBaord a where a is the slot number and b is the socket number CIM_ManagedSystemElement Name Processor in ProcessorBoard a where a is the slot number Processor in socket b on System Mainboard where b is the socket numb...

Страница 175: ...tem name CreationClassName SMX_Processor DeviceID Proc n where n is the processor number CIM_Processor CPUStatus 1 CPU Enabled 2 CPU Disabled by User using BIOS Setup 3 CPU Disabled By BIOS POST Error 4 CPU Idle 7 Other Family Processor family number from SMBIOS for example 179 for Intel R Xeon TM MaxClockSpeed Maximum clock speed in MHz for example 3600 CurrentClockSpeed Current clock speed in MH...

Страница 176: ...erty implementation CIM_ManagedElement Caption Processor Capabilities Description Processor Capabilities CIM_Capabilities InstanceID HPQ SMX_ProcessorCapabilities n where n is a unique number ElementName Processor Capabilities CIM_EnabledLogicalElementCapabilities ElementNameEditSupported 0 False RequestedStatesSupported None CIM_ProcessorCapabilities NumberOfProcessorCores Number of processor cor...

Страница 177: ...r number and c is the core number CIM_ManagedSystemElement Name Processor p Core c where p is the processor number and c is the core number OperationalStatus 0 Unknown 2 OK when CPU is enabled and operational 5 Predictive Failure when IML error information is logged for this CPU 6 Error when CPU is disabled through POST error 10 Stopped when CPU is disabled through RBSU StatusDescriptions StatusDe...

Страница 178: ...tion CIM_ManagedElement Caption Processor p Core c Thread t where p is the processor number c is the core number and t is the thread number Description processor brand string x86 Family x Model y Stepping z Processor p Core c Thread t where processor brand string is the processor brand string x is the processor family number y is the processor model number z is the processor stepping number p is t...

Страница 179: ...nalStatus 0 2 OK 15 Minor Failure when OperationalStatus 0 10 Stopped 20 Major Failure when OperationalStatus 0 5 Predictive Failure 25 Critical Failure when OperationalStatus 0 6 Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 Enabled RequestedState 12 Not Applicable EnabledDefault 2 Enabled CIM_HardwareThread InstanceID HPQ SMX_HardwareThread Proc p Core c Thread t where p is t...

Страница 180: ... x is the cache level number Level x Unified Cache where x is the cache level number Examples Level 1 Data Cache Level 2 Unified Cache CIM_ManagedSystemElement OperationalStatus 0 Unknown 2 OK when CPU is enabled and operational 5 Predictive Failure when IML error information is logged for this CPU 6 Error when CPU is disabled through POST error 10 Stopped when CPU is disabled through RBSU StatusD...

Страница 181: ...p Core c Level x type Cache where p is the processor number c is the core number x is the cache level number and type is the cache type Data Instruction or Unified Examples Proc 1 Level 1 Data Cache Proc 1 Core 2 Level 2 Unified Cache CIM_StorageExtent BlockSize 1 number of bytes in a block NumberOfBlocks Number of blocks in this cache for example 8192 or 524288 Primordial 0 False CIM_Memory HP_Ca...

Страница 182: ...mentCapabilities HP_ProcessorElementCapabilities ManagedElement ref SMX_Processor Capabilities ref SMX_ProcessorCapabilities 7 3 8 SMX_ProcessorCoreComponent SMX_ProcessorCoreComponent extends the class CIM_ConcreteComponent and associates an HP_Processor instance with HP_ProcessorCore instances Table 7 9 Class SMX_ProcessorCoreComponent Property name Property implementation CIM_Component CIM_Conc...

Страница 183: ...sociatedProcessorCacheMemory associates an HP_Processor or an HP_ProcessorCore instance with an HP_CacheMemory instance Table 7 11 Class SMX_AssociatedProcessorCacheMemory Property name Property implementation CIM_Dependency CIM_AssociatedMemory CIM_AssociatedCacheMemory Level 0 Unknown 1 Other 2 Not Applicable 3 Primary 4 Secondary 5 Tertiary WritePolicy 0 Unknown 1 Other 2 Write Back 3 Write Thr...

Страница 184: ...acheMemory Antecedent ref SMX_CacheMemory Dependent ref SMX_Processor SMX_AssociatedProcessorCacheMemory 7 3 11 SMX_ProcessorCollection SMX_ProcessorCollection extends the class HP_GroupSystemSpecificCollection Table 7 12 Class SMX_ProcessorCollection Property name Property implementation CIM_ManagedElement Description A collection of processor packages with group aggregate status ElementName SMX_...

Страница 185: ...tusDescriptions GroupStatusDescriptions 0 text per GroupOperationalStatus 0 Unknown Other OK Degraded Predicted Failure Failed Stopped The status descriptions of the processors that make up the overall operational status are contained in OperationalStatus 1 n See the descriptions for GroupStatusDescriptions for members of the processor collection for the list of possible values HP_ProcessorCollect...

Страница 186: ... Collection ref SMX_ProcessorCollection 7 3 14 SMX_ProcessorChip SMX_ProcessorChip extends the class CIM_Chip to model the physical processor chip Table 7 15 Class SMX_ProcessorChip Properties Property name Property implementation CIM_ManagedElement Caption Processor in ProcessorBoard a where a is the slot number Processor in socket b on System Mainboard where b is the socket number Processor in S...

Страница 187: ...ily string Socket b on ProcessorBoard a where manufacturer string is processor manufacturer name family string is the processor family name string a is the slot number and b is the socket number manufacturer string family string Socket b on System Mainboard where manufacturer string is processor manufacturer name family string is the processor family name string and b is the socket number manufact...

Страница 188: ...el y Stepping z where y is the processor model number and z is the processor stepping number PoweredOn 0 False if CPU is disabled through RBSU or POST error 1 True if CPU is enabled CanBeFRUed 0 False 1 True CIM_PhysicalComponent RemovalConditions 3 Removable When Off CIM_Chip HP_ProcessorChip ProcessorChipRevision Stepping z where z is the processor stepping number 7 3 15 SMX_RealizesProcessor SM...

Страница 189: ...ere the processor is located A socket number designator value of zero indicates one processor is mounted on a processor board A nonzero socket number designator indicates the multiple processor board sockets where a processor is located On modern ProLiant systems processors are mounted in sockets on the system board When the slot number designator is zero the processors are located on the system b...

Страница 190: ...ocket number exists b where b is the socket number when no slot number exists a b where a is the slot number and b is the socket number HP_Location ElementLocationTag ProcessorBoard a where a is the slot number when no socket number exists Socket b on System Mainboard where b is the socket number when no slot number exists Socket b on ProcessorBoard a where a is the slot number and b is the socket...

Страница 191: ...dicates that the second element of the LocationInformation array contains the slot number HP_ProcessorLocation 7 3 18 SMX_ProcessorElementLocation SMX_ProcessorElementLocation extends the class HP_ElementLocation and associates HP_ProcessorChip instances with HP_ProcessorLocation instances Table 7 19 Class SMX_ProcessorElementLocation Property name Property implementation CIM_ElementLocation HP_El...

Страница 192: ... indication OSType On ESX 39 VM On Linux 36 Linux OSVersion The operating system version of the computer system generating the indication in the following format major minor build SystemFirmwareVersion Array of firmware versions of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the comput...

Страница 193: ...mary CPU Failed Power on Self Test POST ProbableCause 1 Other 7 4 2 HP_DeviceIndication Processor Disabled by BIOS or EFI Table 7 22 HP_DeviceIndication Processor Disabled by BIOS or EFI Property name Property implementation CIM_Indication PerceivedSeverity 4 Minor CIM_AlertIndication Description CPU has been disabled by BIOS or EFI AlertType 5 Device Alert EventID 2 EventCategory 2 Processor Prov...

Страница 194: ...ty implementation CIM_Indication PerceivedSeverity 4 Minor CIM_AlertIndication Description CPU Predictive Failure Notification AlertType 5 Device Alert EventID 3 EventCategory 2 Processor ProviderName HP Processor RecommendedActions Replace the failing processor HP_AlertIndication Summary CPU Predictive Failure detected ProbableCause 1 Other ...

Страница 195: ... P115 8 2 Namespaces This provider returns instances in the root hpq namespace 8 3 Class Implementations SMX_Fan SMX_FanCollection SMX_FanRedundancySet SMX_MemberOfFanRedundancy SMX_HostedFanRedundancySet SMX_MemberOfFanCollection SMX_HostedFanCollection SMX_SystemFan SMX_FanLocation SMX_FanElementLocation SMX_FanModule SMX_SystemPhysicalFan SMX_RealizesFan SMX_FanSlot SMX_FanInSlot SMX_SystemFanS...

Страница 196: ...e MP or iLO For example 1 Fan 1a CIM_ManagedSystemElement OperationalStatus 0 2 OK if fan is operating properly 3 Degraded if fan is degraded 6 Error if fan has failed StatusDescriptions 0 Description of the status of the fan correcponding to the OperationStatus Fan is operating properly if OperationalStatus 0 is 2 OK Fan is degraded if OperationalStatus 0 is 3 Degraded Fan has failed if Operation...

Страница 197: ...n SMX_FanCollection is used to model fan collections on Servers There will be one instance of this class on systems modeling fans Table 8 3 Class SMX_FanCollection Property name Property implementation CIM_ManagedElement Caption Cooling Collection Description This is a collection of all devices including fans that provide cooling GroupStatusDescription where GroupStatusDescription represents the v...

Страница 198: ... removed or failed the GroupOperationalStatus is set to 2 OK because this is a valid configuration GroupStatusDescriptions 0 Unknown status for fans if GroupOperationalStatus 0 is 0 Unknown Fans are operating properly if GroupOperationalStatus 0 is 2 OK Fault tolerant fans are degraded if GroupOperationalStatus 0 is 3 Degraded Fans have failed if GroupOperationalStatus 0 is 6 Error 8 3 3 SMX_FanRe...

Страница 199: ...for the redundancy set to provide cooling but fans have failed 4 Redundancy Lost if there are not enough fans required to achieve redundancy but enough for the redundancy set to provide cooling 5 Overall Failure if there are not enough fans operating properly for the redundancy set to provide cooling 8 3 4 SMX_MemberOfFanRedundancy SMX_MemberOfFanRedundancy is used to represent an association betw...

Страница 200: ...X_HostedFanCollection SMX_HostedFanCollection is used to represent an association between HP_FanCollection and the computer system that contains this collection Table 8 8 Class SMX_HostedFanCollection Property name Property implementation Antecedent References HP_ComputerSystem Dependent References HP_FanCollection 8 3 8 SMX_SystemFan SMX_SystemFan is used to represent an association between HP_Fa...

Страница 201: ...mber of the fan position printed on the system HP_Location ElementLocationTag Location string based on ElementLocationTagDescription For exampe on ProLiant Fan n where n represents the fan position printed on the system ElementLocationTagDesc On ProLiant 0 HoodTag 8 3 10 SMX_FanElementLocation SMX_FanElementLocation is used to represent an association between CIM_Location and CIM_ManagedElement Ta...

Страница 202: ...an is operating properly 3 Degraded if fan is degraded 6 Error if fan has failed StatusDescriptions 0 Fan is operating properly if OperationalStatus 0 is 2 OK Fan is degraded if OpertionalStatus 0 is 3 Dedgraded Fan has failed if OperationalStatus is 6 Error HealthState 5 OK if fan is operating properly 10 Degraded if fan is degraded 20 Major Failure if fan has failed Name Fan n where n represents...

Страница 203: ...MX_FanSlot Property name Property implementation CIM_ManagedElement Caption Short description of this fan slot to include the Number For example Fan Slot n where n represents the number of the fan slot Description Description of the fan slot For example Fan Slot n ElementName Name of the fan slot For example Fan Slot n where n represents the number of the fan slot CIM_Managed SystemElement Operati...

Страница 204: ...e SMX_FanInSlot class implements the HP_FanInSlot class and associates the HP_FanSlot instance with HP_FanModule instances Table 8 17 Class SMX_SystemFanInSlot Property name Property implementation Antecedent References HP_FanSlot PartComponent References HP_FanModule 8 4 Supported indications 8 4 1 Provider Indication Common Properties The following table describes the properties that are common ...

Страница 205: ...format major minor build SystemFirmwareVersion Array of firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system ...

Страница 206: ...Description Fan Removed 8 4 3 HP_DeviceIndication Fan Inserted Table 8 20 HP_DeviceIndication Fan Inserted Property name Property implementation CIM_Indication PerceivedSeverity 2 Information CIM_AlertIndication Description A fan has been inserted FanCaption where FanCaption is the SMX_Fan Caption for the fan that has been inserted AlertingManagedElement WBEM path of the SMX_Fan instance represent...

Страница 207: ...FanCaption where FanCaption is the SMX_Fan Caption for the fan that has failed AlertingManagedElement WBEM path of the SMX_Fan instance representing the failed fan AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 3 ProviderName HP Cooling RecommendedActions Please check the failed fan and replace if necessary HP_AlertIndication Summary Fan failed EventCategory 23 System Cooli...

Страница 208: ...mmendedActions No action is recommended HP_AlertIndication Summary Fan repaired EventCategory 23 System Cooling ProbableCause 1 Other ProbableCauseDescription Fan Repaired 8 4 6 HP_DeviceIndication Fan Degraded The repaired indication is not supported on ProLiant Systems as the fans do not report a degraded status Table 8 23 HP_DeviceIndication Fan Degraded Property name Property implementation CI...

Страница 209: ...d Table 8 24 HP_DeviceIndication Fan Redundancy Reduced Property name Property implementation CIM_Indication PerceivedSeverity 2 Information CIM_AlertIndication Description A fault tolerant fan is no longer providing cooling for a cooling redundancy set RedundancySetCaption where RedundancySetCaption represents the SMX_FanRedundancySet Caption for the redundancy set with reduced redundancy Alertin...

Страница 210: ...lost RedundancySetCaption where RedundancySetCaption represents the SMX_FanRedundancySet Caption for the redundancy set that lost redundancy AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance representing the redundancy set where redundancy was lost AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 6 ProviderName HP Cooling RecommendedActions Check the fan c...

Страница 211: ...undancy set with restored redundancy AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 8 ProviderName HP Cooling RecommendedActions No action is recommended HP_AlertIndication Summary Cooling redundancy has been restored EventCategory 23 System Cooling ProbableCause 1 Other ProbableCauseDescription Cooling Redundancy has been Restored 8 4 10 HP_DeviceIndication Fan Redundancy ...

Страница 212: ...Set Caption of the cooling redundancy set with failed redundancy AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance representing the cooling redundancy set with failed redundancy AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 10 ProviderName HP Cooling RecommendedActions Check the fan configuration and check the status of the cooling redundancy Ensure the...

Страница 213: ...spaces This provider returns instances in the root hpq namespace 9 3 Class Implementations SMX_PowerSupply SMX_PowerCollection SMX_PowerRedundancySet SMX_MemberOfPowerRedundancy SMX_HostedPowerRedundancySet SMX_MemberOfPowerCollection SMX_HostedPowerCollection SMX_SystemPowerSupply SMX_PowerSupplyLocation SMX_PowerSupplyElementLocation SMX_PowerSupplyModule SMX_SystemPhysicalPowerSupply SMX_Realiz...

Страница 214: ...anagedSystemElement OperationalStatus 0 2 OK if the power supply is operating properly 3 Degraded if the power supply is degraded 6 Error if the power supply has failed StatusDescriptions 0 Description of the status of the power supply corresponding to the OperationalStatus For example Power Supply is operating properly if OperationalStatus 0 is 2 OK Power Supply is degraded if OperationalStatus 0...

Страница 215: ...ollection is used to model power supply collections on Servers There will be one instance of this class on systems modeling power supplies Table 9 3 Class SMX_PowerCollection Property name Property implementation CIM_ManagedElement Caption Power Collection Description This is a collection of all devices including power supplies that provide power GroupStatusDescription Where GroupStatusDescription...

Страница 216: ... a redundancy status set to 4 Redundancy Lost and no power supplies have been removed or failed the GroupOperationalStatus will be set to 2 OK because this is a valid configuration GroupStatusDescriptions 0 Unknown status for power supplies if GroupOperationalStatus 0 is 0 Unknown Power supplies are operating properly if GroupOperationalStatus 0 is 2 OK Power supplies are degraded if GroupOperatio...

Страница 217: ...et to provide power but power supplies have failed 4 Redundancy Lost if there are not enough power supplies required to achieve redundancy but there are enough for the redundancy set to provide power 5 Overall Failure if there are not enough power supplies operating properly for the redundancy set to provide power 9 3 4 SMX_MemberOfPowerRedundancy SMX_MemberOfPowerRedundancy is used to represent a...

Страница 218: ...on SMX_HostedPowerCollection is used to represent an association between HP_PowerCollection and the computer system that contains this collection Table 9 8 Class SMX_HostedPowerCollection Property name Property implementation Antecedent References HP_ComputerSystem Dependent References HP_PowerCollection 9 3 8 SMX_SystemPowerSupply SMX_SystemPowerSupply is used to represent an association between ...

Страница 219: ... represents the power supply position printed on the system labeling CIM_Location Name Unique identifier for this power supply location instance PhysicalPosition Physical position of this Power Supply For example on Proliant number of represents the power supply position printed on the system HP_Location ElementLocationTag Location string based on ElementLocationTagDescription for example ProLiant...

Страница 220: ... value of StatusDescriptions 0 ElementName Short description of this power supply from the name displayed by the MP or iLO For example Power Supply 1 Power Supply 1a CIM_ManagedSystemElement OperationalStatus 0 2 OK if power supply is operating properly 3 Dedgraded if power supply is degraded 6 Error if power supply has failed StatusDescriptions 0 Description of the status of the power supply corr...

Страница 221: ... 3 13 SMX_RealizesPowerSupply The SMX_RealizesPowerSupply class extends the CIM_Realizes class and associates the HP_PowerSupply instance with HP_PowerSupplyModule instances Table 9 14 Class SMX_RealizesPowerSupply Property name Property implementation Antecedent References HP_PowerSupplyModule Dependent References HP_PowerSupply 9 3 14 SMX_PowerSupplySlot SMX_PowerSupplySlot is used to model phys...

Страница 222: ...n represents the number of the power supply slot CIM_PhysicalElement CreationClassName SMX_PowerSupplySlot Tag Unique identifier for this power supply slot CIM_PhysicalElement CreationClassName SMX_PowerSupplySlot Tag Unique identifier for this power supply slot CIM_ PhysicalPackage ConnectorLayout 6 Slot Number n where n represents the number of the power supply slot 9 3 15 SMX_SystemPowerSupplyS...

Страница 223: ...on Common Properties Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of the indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem Name SystemCreationClassName SMX_ComputerSystem CreationClassName HP_AlertIndication Provider...

Страница 224: ...stem Power Supply indications are described below Table 9 19 HP_DeviceIdentification Power Supply Removed Property name Property implementation CIM_Indication PerceivedSeverity 2 Information CIM_AlertIndication Description A power supply has been removed Power Supply where Power Supply is the system power supply that was removed AlertingManagedElement WBEM path of the SMX_WinPowerSupply instance A...

Страница 225: ...2 CIMObjectPath AlertType 5 Device Alert EventID 2 ProviderName HP Power RecommendedActions No action is recommended HP_AlertIndication Summary Power Supply inserted EventCategory 16 System Power ProbableCause 1 Other ProbableCauseDescription Power Supply has been Inserted 9 4 4 HP_DeviceIndication Power Supply Failed Table 9 21 HP_DeviceIndication Power Supply Failed Property name Property implem...

Страница 226: ... Failed 9 4 5 HP_DeviceIndication Power Supply Degraded Table 9 22 HP_DeviceIndication Power Supply Degraded Property name Property implementation CIM_Indication PerceivedSeverity 5 Major CIM_AlertIndication Description A power supply has failed PowerSupplyCaption where PowerSupplyCaption is the SMX_PowerSupply Caption for the power supply that has degraded AlertingMangedElement WBEM path of the S...

Страница 227: ... A power supply has been repaired No action is recommended PowerSupplyCaption where PowerSupplyCaption is the SMX_PowerSupply Caption for the power supply that has been repaired AlertingManagedElement WBEM path of the SMX_PowerSupply instance representing the failed power supply AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 4 ProviderName HP Power RecommendedActions No act...

Страница 228: ...d redundancy AlertingManagedElement WBEM path of the SMX_PowerRedundancySet instance representing the redundancy set with reduced redundancy AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 5 ProviderName HP Power RecommendedActions No action is recommended HP_AlertIndication Summary Power redundancy has been reduced EventCategory 16 System Power ProbableCause 88 Loss of Redu...

Страница 229: ... the status of the power redundancy Ensure the system is being powered adequately Add or replace power supplies if necessary HP_AlertIndication Summary Power redundancy has been lost EventCategory 16 System Power ProbableCause 88 Loss of Redundancy ProbableCauseDescription Power Redundancy has been Lost 9 4 9 HP_DeviceIndication Power Supply Redundancy Failed This indication is not supported on Pr...

Страница 230: ...ncy failed EventCategory 16 System Power ProbableCause 88 Loss of Redundancy ProbableCauseDescription Power Redundancy has failed 9 4 10 HP_DeviceIndication Power Supply Redundancy Restored Table 9 27 HP_DeviceIndication Power Supply Redundancy Restored Property name Property implementation CIM_Indication PerceivedSeverity 2 Information CIM_AlertIndication Description Power redundancy for the syst...

Страница 231: ...dancy Restored Property name Property implementation ProviderName HP Power RecommendedActions No action is recommended HP_AlertIndication Summary Power redundancy restored EventCategory 16 System Power ProbableCause 1 Other ProbableCauseDescription Power redundancy restored ...

Страница 232: ...3 1 SMX_RegisteredProfile Instances of the SMX_RegisteredProfile class are populated for implemented Distributed Management Task Force DMTF and Storage Networking Industry Association SNIA SMI S storage profiles The following tables list SMX_RegisteredProfile property values and the properties implemented for this class Table 10 2 Class SMX_RegisteredProfile Property name Property implementation C...

Страница 233: ...tName Base Server 1 0 0a DMTF Base Server Profile CPU 1 0 0c DMTF CPU Profile Fan 1 0 0a DMTF Fan Profile Power Supply 1 0 0c DMTF Power Supply Profile System Memory 1 0 0f DMTF System Memory Profile Physical Asset 1 0 0a DMTF Physical Asset Profile OS Status 1 0 0 DMTF OS Status Profile Record Log 1 0 0 DMTF RecordLogProfile Ethernet Port 1 0 0 DMTF Ethernet Port Profile IP Interface 1 0 1 DMTF I...

Страница 234: ...ed in the root hpq namespace The following tables list SMX_RegisteredProfile property values and the properties implemented for this class Table 10 5 Class SMX_RegisteredProfile Property name Property implementation CIM_ManagedElement Caption Table 3 lists the property values for this class Description Table 3 lists the property values for this class ElementName Table 3 lists the property values f...

Страница 235: ...t Profile HP Fan Physical Asset 1 0 0 HP Fan Physical Asset Profile HP Power Supply Physical Asset 1 0 0 HP Power Supply Physical Asset Profile HP CPU Consolidated Status 1 0 0 HP CPU Consolidated Status Profile HP Sensors 1 0 0 HP Sensors Profile HP Record Log 1 0 0b HP Record Log Profile HP Software Inventory 1 0 0 HP SoftwareInventory Profile HP Blade System Lite 1 0 0 HP Blade system Lite Prof...

Страница 236: ...e 10 8 Class SMX_ReferencedProfile Property name Property implementation CIM_Dependency SMX_ReferencedProfile Antecedent ref CIM_RegisteredProfile references Dependent ref CIM_RegisteredProfile referenced 10 3 4 SMX_PRPBaseServerECTP The SMX_PRPBaseServerECTP class extends the class CIM_ElementConformsToProfile and associates the Base Server registered profile with the HP specific central class th...

Страница 237: ...SMX Profile registration provider 237 10 4 Supported indications There are no indications specific to the profile registration implementation ...

Страница 238: ...ow describe temperature sensors SMX_NumericSensor SMX_SensorCollection SMX_SystemSensor SMX_HostedSensorCollection SMX_MemberOfSensorCollection 11 2 2 SMX_NumericSensor SMX_NumericSensor implements HP_NumericSensor and is used to model temperature sensors on Servers Table 11 2 Class SMX_NumericSensor Property name Property implementation CIM_ManagedElement Caption Temperature Sensor sensorID where...

Страница 239: ... Temperature reported by the sensor has exceeded its non critical threshold and the fans have been set to full speed if temperature reported by the sensor has exceeded its threshold and has set fans to full speed Temperature reported by the sensor has exceeded its threshold and the system is gracefully shutting down if that action is enabled if OperationalStatus is 6 Error HealthState 5 OK if Oper...

Страница 240: ...n the system if the threshold is crossed SettableThresholds empty UpperThresholdNonCritical Contains the threshold temperature that CurrentReading must exceed to be in a non critical state This is only set if the system will set fans to full speed if the threshold is crossed UpperThresholdCritical Contains the threshold temperature that CurrentReading must exceed to be in a critical state This is ...

Страница 241: ... critical threshold and the system is gracefully shutting down if that action is enabled GroupStatusDescriptions 0 Temperatures reported by the sensors are operating within normal operating range if temperatures reported by the sensors are within normal operating range Temperatures reported by the sensors have exceeded its non critical threshold and the fans have been set to full speed if temperat...

Страница 242: ...ion 11 2 6 SMX_SystemSensor SMX_SystemSensor implements HP_SystemSensor and is used to represent an association between SMX_NumericSensor and the computer system that contains the sensor Table 11 6 Class SMX_SystemSensor Property name Property implementation GroupComponent References SMX_ComputerSystem PartComponent References SMX_NumericSensor 11 3 Supported indications The following indications ...

Страница 243: ...oper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName HP_ComputerSystem Name SystemCreationClassName HP_ComputerSystem CreationClassName HP_AlertIndication Summary Temperature threshold exceeded detected EventCategory 23 System Cooling ProbableCause 51 Temperature Unacceptable ProbableCauseDescription Temperature Threshold Exceeded Detected...

Страница 244: ... c Class blade systems 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtu...

Страница 245: ...dActions No action is recommended SystemName HP_ComputerSystem Name SystemCreationClassName HP_ComputerSystem CreationClassName HP_AlertIndication Summary Threshold exceeded condition recovery EventCategory 23 System Cooling ProbableCause 52 Threshold Crossed ProbableCauseDescription Threshold Exceeded Condition has Recovered ProviderVersion 2 2 0 0 NetworkAddresses Contains a list of all the IP a...

Страница 246: ...ain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect envir...

Страница 247: ... Physical Asset Profile 1 0 HP Location Profile 1 0 12 2 Namespaces This provider returns instances in the root hpq namespace 1 1Class implementations The following classes are implemented for ProLiant server platforms where available The classes describe system memory resident on a ProLiant server platform SMX_Memory SMX_SystemMemory SMX_MemoryModule SMX_MemoryBoard SMX_RealizesMemoryModule SMX_M...

Страница 248: ...rationalStatus Enumerator indicating the logical system memory operational status The status represents the worst of algorithm for all OperationalStatus 0 values reported by physical memory modules in SMX_MemoryModule instances OperationalStatus 0 shown in order of increasing severity a higher severity overrides a lower severity 2 OK when all physical memory modules report 2 OK 0 Unknown when any ...

Страница 249: ...cable CIM_LogicalDevice CreationClassName SMX_Memory DeviceID HPQ SMX_Memory 000 SystemCreationClassName same value as property SMX_ComputerSystem CreationClassName SystemName same value as property SMX_ComputerSystem Name CIM_StorageExtent Access 3 Read Write Supported BlockSize 1 byte ConsumableBlocks Capacity in bytes NumberOfBlocks Capacity in bytes Primordial True Purpose System Memory Sequen...

Страница 250: ...t in the system Empty memory module sockets will not be instantiated NOTE In the property implementation descriptions below memory modules located on the system board will be denoted as being located on Board cartridge number 0 consistent with ProLiant tradition Table 12 4 Class SMX_MemoryModule Property name Property implementation CIM_ManagedElement Caption Physical Memory Module Socket y on Mem...

Страница 251: ...dicating the memory module health state 0 Unknown when OperationalStatus 0 0 Unknown 5 OK when OperationalStatus 0 2 OK 10 Degraded Warning when OperationalStatus 0 3 Degraded Name Physical Memory Module Socket y on MemoryBoard x where x is the board cartridge number where the memory module is located y is the memory socket number where the memory module is located Physical Memory Module Socket y ...

Страница 252: ...is located Physical Memory Module Socket y on ProcessorBoard x where x the processor board number where the memory module is located y is the memory socket number where the memory module is located Manufacturer Name of the organization which produced the memory module This property is conditional It is populated if the data is available PartNumber Part number of the memory module This property is ...

Страница 253: ...ry module in a row This property is conditional it is populated if the data is available FormFactor Enumerator indicating the form factor of the memory module See the MOF file for details BankLabel String identifying the physically labeled bank where the memory is located This property is conditional It is populated if the data is available SMX_MemoryModule Spd An array that contains raw Serial Pr...

Страница 254: ...Physical Memory MemoryBoard x where x is the board cartridge number where the memory board is located Physical Memory ProcessorBoard x where x is the processor board cartridge number where the memory board is located CIM_ManagedSystemElement OperationalStatus Enumerator indicating the memory board operational status OperationalStatus 0 contains overall memory board status OperationalStatus 1 conta...

Страница 255: ...ssor board cartridge number where the memory board is located ElementName Physical Memory MemoryBoard x where x is the board cartridge number where the memory board is located Physical Memory ProcessorBoard x where x is the processor board cartridge number where the memory board is located CIM_PhysicalPackage RemovalConditions Removal conditions of the memory board When the memory board is the sys...

Страница 256: ...xceeding the condition for pre failure warranty 3 Degraded Degraded 5 Predictive Failure Memory board status Correctable error threshold for pre failure warranty has been exceeded Memory board has a configuration error for example there is a problem with the board release latch unlock error or there is an improper configuration of memory modules on the board 3 Degraded Degraded 3 Degraded Memory b...

Страница 257: ... Memory Module Socket y on ProcessorBoard x where x is the processor board cartridge number where the memory slot is located y is the memory socket number where the memory slot is located CIM_ManagedSystemElement OperationalStatus OperationalStatus 0 2 OK StatusDescriptions StatusDescriptions 0 OK HealthState 5 OK Name Memory Module Socket y on MemoryBoard x where x is the board cartridge number w...

Страница 258: ...s the memory socket number where the memory slot is located Memory Module Socket y on ProcessorBoard x where x is the processor board cartridge number where the memory slot is located y is the memory socket number where the memory slot is located CIM_PhysicalConnector ConnectorLayout 1 Other ConnectorGender 3 Female ConnectorDescription Memory Module Socket y on MemoryBoard x where x is the board ...

Страница 259: ...althState 5 OK Name Memory Board Slot MemoryBoard x where x is the board cartridge number where the memory board is located Memory Board Slot ProcessorBoard x where x is the processor board cartridge number where the memory board is located CIM_PhysicalElement CreationClassName SMX_MemoryBoardSlot Tag HPQ SMX_MemoryBoardSlot x where x is the board cartridge number Description Memory Board Slot Mem...

Страница 260: ...InSlot represents the association between an SMX_MemoryModule and the SMX_MemoryModuleSlot where it resides Table 12 11 Class SMX_MemoryModuleInSlot Property name Property implementation CIM_ElementInConnector HP_ MemoryModuleInSlot SMX_MemoryModuleInSlot Antecedent ref SMX_MemoryModuleSlot Dependent ref SMX_MemoryModule 12 2 9 SMX_MemoryBoardInSlot The class SMX_MemoryBoardInSlot represents the a...

Страница 261: ...ss and represents memory module slot locations on ProLiant Servers There will be an instance of this class for each memory module slot in the system whether the slot is occupied or not Table 12 14 Class SMX_ MemoryModuleSlotLocation Property name Property implementation CIM_ManagedElement Caption Memory Module Socket Location Socket y on MemoryBoard x where x is the board cartridge number where th...

Страница 262: ...umber where the memory module slot is located Memory Module Socket Location Socket y on ProcessorBoard x where x is the processor board cartridge number where the memory module slot is located y is the memory socket number where the memory module slot is located CIM_Location Name HPQ SMX_MemoryModuleSlotLocation x y where x is the board cartridge number where the memory module slot is located y is...

Страница 263: ...perty name Property implementation CIM_ManagedElement Caption Memory Board Slot Location MemoryBoard x where x is the board cartridge number where the memory board slot is located Memory Board Slot Location ProcessorBoard x where x is the processor board cartridge number where the memory board slot is located Description Memory Board Slot Location MemoryBoard x where x is the board cartridge numbe...

Страница 264: ...ation The class SMX_MemoryModuleSlotElementLocation extends the class CIM_ElementLocation and is used to associate a memory module slot SMX_MemoryModuleSlot with its corresponding location SMX_MemoryModuleSlotLocation There is an instance of this class for each memory module slot in the system regardless of the slot occupation Table 12 16 Class SMX_MemoryModuleSlotElementLocation Properties Proper...

Страница 265: ...system board resident memory module slots are instantiated Table 12 18 Class SMX_SystemMemoryModule Properites Property implementation CIM_Container HP_SystemMemoryModule SMX_SystemMemoryModule GroupComponent ref SMX_ComputerSystemChassis PartComponent ref SMX_MemoryModule 12 2 16 SMX_SystemMemoryBoard The class SMX_SystemMemoryBoard represents an association between SMX_MemoryBoard and SMX_Comput...

Страница 266: ...nceID HPQ SMX_MemoryRedundancySet 001 CIM_RedundancySet TypeOfSet The type of redundancy currently in operation for the Advanced Memory Protection system This property corresponds functionally to the property CurrentConfiguration TypeOfSet 0 contains the current type of redundancy 1 Other when the system is operating in Advanced ECC or Lockstep mode 2 N 1 when the system is operating in RAID XOR m...

Страница 267: ...anty HP_MemoryRedundancySet OperatingSpeed The current operating speed of the Advanced Memory Protection subsystem in MHz AvailableMemory The size of the memory as seen by the operating system in MB TotalMemory Total size of memory as seen by the operating system and memory used for Advanced Memory Protection configurations in MB CurrentConfiguration The current operating mode of the Advanced Memo...

Страница 268: ...rations supported on this system the CurrentConfiguration and TargetConfiguration properties will contain one of these values Each indexed position in the array contains one supported configuration Possible values are Advanced ECC Online Spare Mirrored RAID Lockstep 12 2 18 SMX_MemoryCollection The class SMX_MemoryCollection represents physical memory collections on ProLiant Servers The collection...

Страница 269: ... see the Memory Collection Status GroupStatusDescriptions GroupStatusDescriptions 0 contains descriptive text per GroupOperationalStatus 0 Memory collection status OK Memory collection status Degraded Memory collection status Unknown HP_MemoryCollection Table 12 22 Memory Collection Status RedundancyStatus from SMX_MemoryRedundan cySet worst OperationalStatus 0 SMX_MemoryBoard worst OperationalSta...

Страница 270: ...ection The class SMX_ MemberOfMemoryCollection represents an association between SMX_MemoryCollection and SMX_MemoryModule or SMX_MemoryBoard Table 12 24 Class SMX_MemberOfMemoryCollection Property name Property implementation CIM_MemberOfCollection HP_MemberOfMemoryCollection SMX_MemberOfMemoryCollection Collection ref SMX_MemoryCollection Member ref CIM_PhysicalElement either SMX_MemoryModule or...

Страница 271: ...emoryRedundancySet SMX_HostedMemoryRedundancySet OwningElement ref SMX_ComputerSystem OwnedElement ref SMX_MemoryRedundancySet 12 2 23 SMX_SystemMemoryModuleSlot The class SMX_SystemMemoryModuleSlot represents an association between SMX_MemoryModuleSlot and SMX_ComputerSystemChassis There is an instance of this class for each memory module slot on the chassis system board regardless of the occupat...

Страница 272: ... Provider indications that are implemented for server platforms where available Table 12 29 Provider Indication Common Properties Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_Com...

Страница 273: ...ms where available Table 12 30 SMX_MemoryIndication Memory Module Predictive Failure Property name Property implementation CIM_Indication PercieivedSeverity 5 Major CIM_AlertIndication Description A memory module has failed or is predicted to fail MemoryModuleCaption where MemoryModuleCaption is the SMX_MemoryModule Caption for the failing memory module AlertingManagedElement WBEM Path of SMX_Memo...

Страница 274: ...XMemory RecommendedActions Check the memory configuration and replace the memory board and memory modules as necessary HP_AlertIndication Summary Memory board error EventCategory 3 Memory ProbableCause 1 Other ProbableCauseDescription Memory B CIM_Indication PerceivedSeverity 5 Major CIM_AlertIndication Description The Advanced Memory Protection AMP system is operating with degraded redundancy The...

Страница 275: ...ation Description The Advanced Memory Protection AMP system is operating normally in the targeted configuration If redundancy was previously degraded redundancy has been restored TargetConfiguration where TargetConfiguration is SMX_MemoryRedundancySet TargetConfiguration AlertingManagedElement WBEM Path of SMX_MemoryRedundancySet instance representing the Memory Redundancy AlertingElementFormat 2 ...

Страница 276: ... Administrator and association to the individual blade system 13 3 1 SMX_BladeEnclosureCS SMX_BladeEnclosureCS extends the class HP_ComputerSystem and describes a blade computer system enclosure The following properties are implemented Table 13 2 Class SMX_BladeEnclosureCS Property name Property implementation CIM_ManagedElement Caption If enclosure name exists HP BladeSystem enclosure enclosure n...

Страница 277: ... Unknown enclosure status Unknown 5 OK enclosure status OK 10 Degraded Warning enclosure status Degraded 20 Major Failure enclosure status Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 Not Applicable RequestedState 12 Not Applicable EnabledDefault 2 Enabled CIM_System CreationClassName HP_BladeEnclosureCS CIM_ComputerSystem Dedicated 2 Other OtherDedicatedDescriptions Modular I...

Страница 278: ...lowing properties are implemented Table 13 3 Class SMX_BladeEnclosureCollection Property name Property implementation CIM_ManagedElement Description A collection of server blade enclosures with group aggregate status ElementName Server Blade Enclosure Collection CIM_Collection CIM_SystemSpecificCollection InstanceID HPQ HP_BladeEnclosureCollection 001 HP_GroupSystemSpecificCollection Caption Serve...

Страница 279: ... to the blade s computer system instance The following properties are implemented Table 13 4 Class SMX_BladeSystemComponent Property name Property implementation CIM_Component CIM_SystemComponent HP_BladeSystemComponent GroupComponent ref HP_ComputerSystem the blade enclosure computer system PartComponent ref HP_ComputerSystem the blade servers computer system 13 3 4 SMX_MemberOfBladeEnclosureColl...

Страница 280: ...y CIM_HostedCollection HP_GroupHostedCollection HP_BladeEnclosureGroupHostedCollection Antecedent ref HP_ComputerSystem Dependent ref HP_BladeEnclosureCollection 13 3 6 CIM_SoftwareIdentity CIM_SoftwareIdentity describes blade enclosure firmware The Windows specific implementation class is HP_BladeEnclosureFW The following table lists the properties implemented Table 13 7 Class CIM_SoftwareIdentit...

Страница 281: ...ns 10 Firmware ClassificationDescriptions HP Server Blade Enclosure Firmware IdentityInfoValue An array in which first element contains the path of the target type firmware family and the second element is HPQ OA IdentityInfoType CIM SoftwareFamily HP_BladeEnclosureFW 13 3 7 CIM_ElementSoftwareIdentity CIM_ElementSoftwareIdentity associates a blade enclosure to its corresponding firmware The Windo...

Страница 282: ...cation SMX_BladeCSLocation is used to model the server blade location within an enclosure Table 13 10 Class SMX_BladeCSLocation Property name Property implementation CIM_ManagedElement Caption Blade Computer System Bay Location n where n represents the blade bay slot position printed on the enclosure labeling Description Blade Computer System Bay Location n where n represents the blade bay slot po...

Страница 283: ...Desc LocationInfoDesc 0 14 Blade Bay 13 3 10 SMX_BladeCSElementLocation SMX_BladeCSElementLocation is used to represent an association between CIM_Location and CIM_ManagedElement Table 13 11 Class HP_ElementLocation Property name Property implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location 13 4 Supported indications There are no indications specific to the...

Страница 284: ... files installed by this provider Table 14 1 Overview Implemented Profiles SNIA SMI S FC HBA Profile Host book 1 4 0 r1 HP FC HBA Profile 1 0 14 2 Namespaces This provider returns instances in the root hpq namespace 14 3 Class implementations 14 3 1 SMX_FCHBAComputerSystem SMX_FCHBAComputerSystem is used to idenitfy classes that represent all Fibre Channel ports Table 14 2 Class SMX_FCHBAComputerS...

Страница 285: ...erSystem NameFormat Other CIM_ComputerSystem Dedicated 0 IdentifyingDescriptions 0 HPQ GUID OtherIdentifyingInfo 0 GUID 14 3 2 SMX_FCBAFCPort SMX_FCHBAFCPort is used to represent a Fibre Channel port device Table 14 3 Class SMX_FCHBAFCPort Property name Property implementation CIM_ManagedElement ElementName Fibre Channel Port port controller number port number Where FC port controller number is th...

Страница 286: ...nt CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_LogicalDevice CreationClassName SMX_FCHBAFCPort DeviceID Opaque value SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_LogicalPort MaxSpeed One of in Bits per Second 0 1000000000 2000000000 10000000000 OtherPortType other Not present Fabric Public Loop...

Страница 287: ...er is a logical device corresponding to a hardware network port controller Table 14 4 Class SMX_FCHBAPortController Property name Property implementation CIM_ManagedElement ElementName Product Name CIM_ManagedSystemElement Name NodeWWN CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_LogicalDevice CreationClass...

Страница 288: ...ct name CIM_StatisticalData InstanceID Opaque SampleInterval 0 CIM_NetworkPortStatistics BytesTransmitted HBAAPI_PORTSTATISTICS TxWords BytesReceived HBAAPI_PORTSTATISTICS RxWords PacketsTransmitted HBAAPI_PORTSTATISTICS TxFrames PacketsReceived HBAAPI_PORTSTATISTICS RxFrames CIM_FCPortStatistics CRCErrors HBAAPI_PORTSTATISTICS InvalidCRCCount DumpedFrames HBAAPI_PORTSTATISTICS DumpedFrames ErrorF...

Страница 289: ...Property implementation CIM_ManagedElement Description Grouping of all FC Ports for this HBA Caption Logical Port Group ElementName Logical Port Group CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque CIM_LogicalPortGroup Name NodeWWN NameFormat WWN 14 3 6 SMX_FCHBAPhysicalPackage SMX_FCHBAPhysicalPackage class represents the physical elements of the associated Fibre Channel port contr...

Страница 290: ...ersion or N A when not available CIM_PhysicalPackage RemovalConditions 2 Not Applicable 14 3 7 SMX_FCHBAProduct SMX_FCHBAProduct is used to aggregate physical element of the FC HBA In the following table HBAAPI_ADAPTERATTRIBUTES prefix refers to the HBA API HBA_ADAPTERATTRIBUTES structure This information comes directly for the HBA and is not altered Table 14 8 Class SMX_FCHBAProduct Property name...

Страница 291: ... InstanceID HPQ NodeWWN instanceNum where instanceNum is the port controller instance number for the same adapter Manufacturer Manufacturer VersionString File version of the Driver 14 3 9 SMX_FCHBAFirmwareIdentityFW SMX_FCHBA_FirmwareIdentityFW represents adapter firmware associated with the Fibre Channel port controller Table 14 10 Class SMX_FCHBAFirmwareIdentityFW Property name Property implemen...

Страница 292: ...h the Fibre Channel port controller Table 14 11 Class SMX_FCHBA_FirmwareIdentityBIOS Property name Property implementation CIM_ManagedElement Caption FC HBA Option ROM Description FC HBA Option ROM detail for Model Name where product name is the model name of the HBA ElementName FC HBA Option ROM CIM_ManagedSystemElement Name NodeWWN CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptio...

Страница 293: ...ts Table 14 12 Class SMX_FCHBAGroupSystemSpecificCollection Property name Property implementation CIM_ManagedElement Caption FC HBA Consolidated Status Description Consolidated status for HP FC HBAs ElementName FC HBA Consolidated Status CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque HP_GroupSystemSpecificCollection GroupOperationalStatus 0 0 Unknown 1 Other 2 OK 3 Degraded 6 Error ...

Страница 294: ...rSystem and SMX_FCHBAPortController Table 14 14 Class SMX_FCHBAComputerSystemPortController Property name Property implementation CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemPortController GroupComponent ref SMX_FCHBAComputerSystem PartComponent ref SMX_FCHBAPortController 14 3 14 SMX_FCHBA_ComputerSystemLogicalPortGroup SMX_FCHBA_ComputerSystemLogicalPortGroup is used to represent an as...

Страница 295: ...InstalledSoftware ref SMX_FCHBASoftwareIdentityDrv System ref SMX_FCHBAComputerSystem 14 3 16 SMX_FCHBA_FCPortFCPortStatistics SMX_FCHBA_FCPortFCPortStatistics is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAFCPortStatistics Table 14 17 Class SMX_FCHBA_FCPortFCPortStatistics Property name Property implementation CIM_ElementStatisticalData SMX_FCHBAFCPortFCPortStatistics Ma...

Страница 296: ... name Property implementation CIM_Dependency CIM_ControlledBy SMX_FCHBAPortControllerFCPort Antecedent ref SMX_FCHBAPortController Dependent ref SMX_FCHBAFCPort 14 3 19 SMX_FCHBAPhysicalPackagePortController SMX_FCHBAPhysicalPackagePortController is used to represent an association between SMX_FCHBAPortController and SMX_FCHBA_PhysicalPackage Table 14 20 Class SMX_FCHBA_PhysicalPackagePortControll...

Страница 297: ...ntroller and SMX_FCHBAFirmwareIdentityFW Table 14 22 Class SMX_FCHBAPortControllerFirmwareIdentityFW Property name Property implementation CIM_Dependency CIM_ElementSoftwareIdentity SMX_FCHBAPortControllerFirmwareIdentityFW Antecedent ref SMX_FCHBAFirmwareIdentityFW Dependent ref SMX_FCHBAPortController 14 3 22 SMX_FCHBAPortControllerFirmwareIdentityBIOS SMX_FCHBAPortControllerFirmwareIdentityBIOS...

Страница 298: ...mPackaging is used to represent an association between SMX_FCHBAPhysicalPackage and SMX_FCHBAComputerSystem Table 14 25 Class SMX_FCHBASystemPackaging Property name Property implementation CIM_Dependency CIM_SystemPackaging SMX_FCHBASystemPackaging Antecedent ref SMX_FCHBAPhysicalPackage Dependent ref SMX_ FCHBAComputerSystem 14 3 25 SMX_FCHBAGroupHostedCollection SMX_FCHBAGroupHostedCollection is...

Страница 299: ... implementation CIM_MemberOfCollection SMX_FCHBAFCPortGroupSystemSpecific Collection ref SMX_FCHBAGroupSystemSpecificCollection Member ref SMX_FCHBAFCPort 14 3 27 SMX_FCHBALocation SMX_FCHBALocation is used to specify the location of the HBA PCI Slot number Table 14 28 Class SMX_FCHBALocation Property name Property implementation CIM_ManagedElement CIM_Location Name NodeWWN SerialNumber instanceNu...

Страница 300: ...r represents a protocol controller that manages a SCSI interface This class is used for backward compatibility with SMI S 1 0 Table 14 30 Class SMX_FCHBASCSIProtocolController Property name Property implementation CIM_ManagedElement ElementName ProductName CIM_ManagedSystemElement OperationalStatus 0 0 Unknown 2 OK Online 6 Error 10 Stopped 11 In Service CIM_LogicalElement CIM_EnabledLogicalElemen...

Страница 301: ...nabledLogicalElement EnabledDefault 2 Enabled RequestedState 12 Not Applicable CIM_ServiceAccessPoint CreationClassName SMX_FCHBASCSIProtocolEndpoint SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolEndpoint ProtocolFType 57 HIPPI Interface CIM_SCSIProtocolEndpoint ConnectionType 2 fibre channel Role 2 initiator 14 3 31 SMX_FCHBAComputerSystemSCSIProtocolControll...

Страница 302: ...mentation SMX_FCHBAFCPortSCSIProtocolEndpoint Antecendent ref SMX_FCHBAPort Dependent ref SMX_FCHBASCSIProtocolEndpoint 14 3 33 SMX_FCHBASCSIProtocolControllerFCPort SMX_FCHBASCSIProtocolControllerFCPort is used to represent an association between SMX_FCHBASCSIProtocolController and SMX_FCHBAFCPort Table 14 34 Class SMX_FCHBAFCPortSCSIProtocolControllerFCPort Property name Property implementation ...

Страница 303: ...ystem Dependent ref SMX_ FCHBASCSIProtocolEndpoint 14 3 35 SMX_FCHBAConcreteIdentity SMX_FCHBAConcreteIdentity is used to represent an association between SMX_ComputerSystem and SMX_FCHBAComputerSystem Table 14 36 Class SMX_ FCHBAConcreteIdentity Property name Property implementation CIM_LogicalIdentity CIM_ConcreteIdentity SMX_FCHBAConcreteIdentity SystemElement ref SMX_ComputerSystem SameElement...

Страница 304: ...sor systems and their relationship to the computer system on which they reside 15 3 1 SMX_ManagementProcessor SMX_ManagementProcessor extends the class HP_ManagementProcessor and describes a management processor controller system The following properties are implemented Table 15 2 Class SMX_ManagementProcessor Property name Property implementation CIM_ManagedElement Caption Product name of the man...

Страница 305: ...MP product same as the product name in property ElementName For example Active HP Management Processor Integrated Lights Out iLO ElementName Product name of the management processor For example Product name of the management processor in format product name X Where product name is the name of the MP product X indicates whether the MP is Active or Inactive Disabled Examples Remote Insight Board Lig...

Страница 306: ...t when NICCondition 4 Note When a Management Processor is disabled refer to property EnabledState OperationalStatus 0 will always report a status of 2 OK so as not to contribute negatively to overall system status An MP is disabled only if the user has manually disabled it through the MP s RBSU settings this is seen as a normal condition In this scenario OperationalStaus 1 is not populated StatusD...

Страница 307: ...ys report a state of 5 OK so as not to contribute negatively to overall system status An MP is disabled only if the user has manually disabled it via the MP s RBSU settings this is seen as a normal condition CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 Enabled for active MP 3 Disabled for inactive disabled MP RequestedState 12 Not Applicable EnabledDefault 2 Enabled CIM_System Creat...

Страница 308: ...ocessor UniqueIdentifier String which uniquely distinguishes the management processor controller from any other MP hardware IPAddress The IP address of the MP resident network interface URL The Uniform Resource Locator of the management processor controller s web based user interface Note When a Management Processor is disabled refer to property EnabledState URL will always be reported as https 0 ...

Страница 309: ...erty name Property implementation CIM_ManagedElement Caption Short description of the MP firmware for example Management Processor Firmware Description HP Management Processor Firmware ElementName The target type firmware family For example RI7 for iLO2 CIM_ManagedSystemElement Name Product name of the management processor Examples Integrated Lights Out 2 ILO2 OperationalStatus 2 OK 6 Error when M...

Страница 310: ...amily For IdentityInfoType CIM SoftwareFamily the value will represent the target type firmware family Examples HPQ RI7 for ProLiant iLO 2 HPQ iLO2 for Integrity iLO 2 HPQ MP for Integrity MP IdentifyingInfoType CIM SoftwareFamily ReleaseDate The MP firmware date in DMTF datetime format HP_MPFirmware 15 3 3 SMX_MPCollection SMX_MPCollection implements the class HP_MPCollection and represents the c...

Страница 311: ...tatusDescriptions 0 text per GroupOperationalStatus 0 Aggregate Management Processor Collection Status Unknown Aggregate Management Processor Collection Status OK Aggregate Management Processor Collection Status Degraded Aggregate Management Processor Collection Status Error SMX_MPCollection 15 3 4 SMX_MPHostedCollection SMX_MPHostedCollection extends the class HP_GroupHostedCollection and associa...

Страница 312: ...he class HP_MPMemberOfCollection and associates a management processor to the collection to which it belongs The following properties are implemented Table 15 7 Class SMX_MPMemberOfCollection Property name Property implementation CIM_MemberOfCollection CIM_MemberOfPolicyCollection Collection ref HP_MPCollection Member ref HP_ManagementProcessor 15 3 7 CIM_MPElementFirmwareIdentity SMX_MPElementFir...

Страница 313: ...eIdentity SMX_MPInstalledFirmwareIdentity implements the CIM_InstalledSoftwareIdentity class and associates a management processor to its corresponding installed firmware The following properties are implemented Table 15 9 Class SMX_MPInstalledFirmwareIdentity Property name Property implementation CIM_InstalledSoftwareIdentity HP_MPInstalledFirmwareIdentity System ref HP_ManagementProcessor Instal...

Отзывы: