Hard Drive Option
The server blade hot-plug SCSI hard drives have unique SCSI IDs that the
system automatically sets. The IDs number from top to bottom on each server
blade.
IMPORTANT: Always populate hard drive bays starting with SCSI ID 0
(the top bay).
To install the component:
CAUTION: To prevent improper cooling and thermal damage,
do not operate the server unless all bays are populated with either a
component or a blank.
1. Remove the hard drive blank.
NOTE: Port-colored items indicate hot-plug components.