Component
Identification
11
Hot-Plug SCSI Hard Drive LED Combinations
Activity
LED (1)
Online
LED (2)
Fault LED
(3)
Interpretation
On, off, or
flashing
On or off
Flashing
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
On, off, or
flashing
On
Off
The drive is online and is configured as part of an array.
If the array is configured for fault tolerance and all other drives in the
array are online, and a predictive failure alert is received or a drive
capacity upgrade is in progress, you may replace the drive online.
On or
flashing
Flashing Off
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding or undergoing capacity expansion.
On Off Off Do not remove the drive.
The drive is being accessed, but (1) it is not configured as part of an
array; (2) it is a replacement drive and rebuild has not yet started; or
(3) it is spinning up during the POST sequence.
Flashing Flashing Flashing Do not remove the drive. Removing a drive may cause data loss
in non-fault-tolerant configurations.
Either (1) the drive is part of an array being selected by an array
configuration utility; (2) Drive Identification has been selected in
HP SIM; or (3) drive firmware is being updated.
Off
Off
On
The drive has failed and has been placed offline.
You may replace the drive.
Off
Off
Off
Either (1) the drive is not configured as part of an array; (2) the drive
is configured as part of an array, but it is a replacement drive that is
not being accessed or being rebuilt yet; or (3) the drive is configured
as an online spare.
If the drive is connected to an array controller, you may replace the
drive online.
Содержание BL25p - ProLiant - 1 GB RAM
Страница 1: ...HP ProLiant BL25p Server Blade User Guide January 2005 First Edition Part Number 377853 001 ...
Страница 20: ......
Страница 24: ......
Страница 37: ...Hardware Options Installation 37 3 Install the BBWC memory module on the Smart Array 6i controller ...
Страница 38: ......
Страница 44: ......
Страница 82: ...82 HP ProLiant BL25p Server Blade User Guide ...
Страница 84: ...84 HP ProLiant BL25p Server Blade User Guide ...
Страница 86: ...86 HP ProLiant BL25p Server Blade User Guide ...
Страница 88: ...88 HP ProLiant BL25p Server Blade User Guide ...
Страница 91: ...Troubleshooting 91 ...
Страница 94: ...94 HP ProLiant BL25p Server Blade User Guide ...
Страница 100: ...100 HP ProLiant BL25p Server Blade User Guide Japanese Notice BSMI Notice ...
Страница 106: ...106 HP ProLiant BL25p Server Blade User Guide Width 26 14 cm 10 29 in Weight maximum 9 43 kg 20 8 lb ...