Cabling and Powering Up the System
HP ProLiant BL p-Class System Setup and Installation Guide
4-19
HP CONFIDENTIAL
Writer: Christine Portillo File Name: e-ch4 Cabling and Powering Up the System.doc
Codename: ICE Part Number: 230852-002 Last Saved On: 11/20/02 4:57 PM
To connect power cables to the bus bars:
IMPORTANT:
You need a Torx T25 driver to connect DC power cables to a scalable or
mini bus bar.
IMPORTANT:
Install the power cabling for bus bar connections on bus A first.
IMPORTANT:
If the configuration does not include power enclosures, omit steps
1 through 10, below. Refer to the documentation that ships with the facility DC cables
option installation kit.
1.
Remove the screws securing the access cover to the bus bar (1).
2.
Remove the access cover from the bus bar (2).
IMPORTANT:
When you remove the cable guide, the protective caps for the P2 power
cable connections are freed. Save these caps to reinstall them later.
3.
Remove the screw securing the cable guide (3).
4.
Remove the cable guide (4).
Figure 4-12: Removing the access cover and cable
guide (scalable bus bar shown)