Removal and replacement procedures 67
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
System Options
menu.
3.
Select
Serial Number
. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the system
during the manufacturing process and should NOT be modified. This option
should only be used by qualified service personnel. This value should
always match the serial number sticker located on the chassis.
4.
Press the
Enter
key to clear the warning.
5.
Enter the serial number and press the
Enter
key.
6.
Select
Product ID
.
7.
Enter the product ID and press the
Enter
key.
8.
Press the
Esc
key to close the menu.
9.
Press the
Esc
key to exit RBSU.
10.
Press the
F10
key to confirm exiting RBSU. The server will automatically reboot.