Cabling and powering up the chassis 40
2.
Move the cable management arm to the right rack rail and align the tab for opposite side mounting.
3.
Align and install the cable management arm on the right rack rail.
I/O module option cabling
The HPE Apollo 4500 system with its centralized HPE Smart Storage Battery supports up to two HPE
Smart Array controllers per node.
When an I/O module with the x16 riser option is installed, PCIe slot 2 is reserved for x16 options and the
HPE H240 Smart Host Bus Adapter options must be installed in PCIe slots 1 and 3.
This chassis supports one I/O module. Standard x8 I/O modules have four PCIe slots and one
FlexibleLOM slot while x16 I/O modules have four PCIe slots. This section describes the cable routing for
the options installed in the I/O module.