HP StorageWorks 1500 Modular Smart Array installation guide
81
Installing the current Fibre_SCSI patch on the servers
1.
Download the current patch from the HP OpenVMS Systems website:
http://h71000.www7.hp.com/serv_support.html
.
a.
Navigate to the
HP Proactive service tools
banner.
b.
Select one of the following options:
•
Register to access the HP Patch Database
• FTP site for OpenVMS patches
c.
Follow the onscreen instructions to navigate to and download the patch.
2.
For existing OpenVMS installations:
a.
Assign a unique identifier to the MSA controller. For instructions, see the MSA1000/1500
Command Line Interface user guide.
b.
On each OpenVMS server, install the Fibre_SCSI patch on all system disks. For instructions,
see the documentation that came with the kit.
3.
If you do not have an existing OpenVMS installation:
a.
Create at least one LUN on the MSA. For instructions, see the MSA1000/1500 Command
Line Interface user guide.
b.
Assign a unique identifier to the MSA controller. For instructions, see the MSA1000/1500
Command Line Interface user guide.
c.
Install OpenVMS on the server. For instructions, see your version-specific OpenVMS upgrade
and installation manual.
d.
Install the Fibre_SCSI patch on all system disks. For instructions, see the documentation that
came with the kit.
e.
Restart the OpenVMS server.
Table 11
OpenVMS Fibre_SCSI patches (as of August 2006)
OpenVMS version
Fibre_SCSI patch
OpenVMS 7.3-2
VMS732_FIBRE_SCSI-V0900
OpenVMS 8.2 (Alpha)
VMS82A_FIBRE_SCSI-V0200
OpenVMS 8.2 (Itanium)
VMS82I_FIBRE_SCSI-V0200
OpenVMS 8.2-1 (Itanium)
VMS821I_FIBRE_SCSI-V0200
Содержание AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Страница 60: ...Installation procedures All deployments 60 ...
Страница 66: ...Configuration procedures Windows environments 66 ...
Страница 72: ...Configuration procedures Linux environments 72 ...
Страница 78: ...Configuration procedures HP UX environments 78 ...
Страница 84: ...Configuration procedures OpenVMS environments 84 ...
Страница 96: ...Configuration procedures Other environments 96 ...
Страница 100: ...Powering off and powering on the MSA 100 ...
Страница 106: ...Electrostatic discharge 106 ...
Страница 126: ...126 ...