Configuration procedures—Linux environments
70
d.
Start the ACU by entering one of the following commands:
• To enable remote access, enter:
/usr/sbin/cpqacuxe -R
• To disable remote access, enter:
/usr/sbin/cpqacuxe -d
9.
To install the Array Configuration Utility - Command Line Interface:
a.
Navigate to the
/HPACUCLI/Linux
directory on the CD.
b.
List the contents of the directory and identify the directory for your processor type.
c.
Change to the CD directory for your processor type and list the contents of the directory.
d.
Install the ACU-CLI by entering:
rpm -ivh <HPACUCLI_rpm_filename>
(Where
<HPACUCLI_rpm_filename>
is the name of the ACU-CLI rpm.)
10.
After all desired components are installed, remove the Support Software CD from the CD-ROM
drive.
11.
Restart the server.
12.
Repeat these procedures for each Linux server that will access the MSA.
Updating MSA controller firmware (if necessary)
If you need to update the firmware on your MSA controller to a version downloaded from the
MSA1500 website, do so at this time.
For information on determining whether you need to update MSA controller firmware, see the
following sections in this guide:
•
”
Determine which version of MSA controller firmware to use
” on page 15
•
”
Obtain desired controller firmware and Support Software CD versions
” on page 56
For instructions on updating MSA controller firmware, see the MSA 1000/1500 firmware updating
guide, available on the MSA1500 website:
http://www.hp.com/go/msa1500cs
.
IMPORTANT:
After updating MSA controller firmware, be sure to check the status of the MSA for
unexpected issues. Verify the status of the connections, defined profile types, redundancy settings,
and storage configuration.
Содержание AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Страница 60: ...Installation procedures All deployments 60 ...
Страница 66: ...Configuration procedures Windows environments 66 ...
Страница 72: ...Configuration procedures Linux environments 72 ...
Страница 78: ...Configuration procedures HP UX environments 78 ...
Страница 84: ...Configuration procedures OpenVMS environments 84 ...
Страница 96: ...Configuration procedures Other environments 96 ...
Страница 100: ...Powering off and powering on the MSA 100 ...
Страница 106: ...Electrostatic discharge 106 ...
Страница 126: ...126 ...