Hardware
Installation
1.
Shut
down
Windows
95
and
turn
o
the
computer
.
2.
Remove
the
computer
cover
and
install
the
GPIB
interface
card.
If
possible
,
avoid
using
the
rst
or
last
slot
as
it
is
dicult
to
connect
the
GPIB
interface
cable
with
the
card
in
either
of
these
locations
.
3.
Turn
on
the
computer
and
load
Windows
95.
Hardware
V
erication
1.
Select
Start,
Settings,
Control
P
anel.
2.
From
the
Control
P
anel
window
select
the
System
icon.
3.
From
the
System
window
,
select
Device
Manager
then
National
Instruments.
4.
Select
A
T-GPIB/TNT,
Properties,
then
Resources.
V
erify
that
the
I/O
range
,
DMA,
and
Interrupt
Request
are
the
same
values
as
what
were
set
on
the
card,
and
there
are
no
conicts
.
5.
Close
out
the
Control
P
anel
category
.
6.
T
o
test
the
A
T-GPIB/TNT
card,
select
Start,
Program,
NI
488.2M
Software
for
Windows
95,
Diagnostics.
7.
From
the
Diagnostics
window
,
select
T
est
All.
8.
When
the
message
\Please
close
all
GPIB
applications"
appears
,
select
OK.
9.
When
the
test
is
complete
\P
assed"
will
be
displayed.
Select
OK.
If
the
test
does
not
pass
,
refer
to
the
A
T-GPIB/TNT
Getting
Started
manuals
for
more
information.
Setting
Up
A
T-GPIB/TNT
for
Windows
NT
4.0
The
following
four
sections
describe
the
Windows
NT
4.0
setup
and
installation
of
both
hardware
and
software
for
the
A
T-GPIB
interface
card.
Software
Installation
1.
Insert
the
NI-488.2
Software
for
Windows
and
the
A
T-GPIB/TNT
disk
into
the
disk
drive
.
2.
Run
setup
.exe.
3.
F
ollow
the
setup
instructions
displayed
on
the
computer
screen
to
complete
the
installation.
Hardware
Setup
and
Installation
1.
Select
an
unused
DMA.
If
there
is
a
conict,
remove
the
DMA
jumper
on
the
A
T-GPIB/TNT
board;
this
sets
the
DMA
to
none.
2.
Set
the
Base
I/O
A
ddress
to
an
unused
address
in
your
personal
computer
.
The
default
Base
I/O
A
ddress
is
(hex)
2C0.
3.
Set
the
Interrupt
Level
(IRQ)
to
an
unused
interrupt
in
your
computer
.
The
default
Interrupt
Level
is
11.
7-8
Using
the
HP
84125C
Utility
Содержание 84125C
Страница 7: ......
Страница 13: ......
Страница 19: ...Figure 2 1 HP 84125C System Dimensions 2 4 Speci cations and Characteristics ...
Страница 23: ...Declaration of Conformity Figure 2 5 Declaration of Conformity 2 8 Speci cations and Characteristics ...
Страница 45: ......
Страница 55: ...DLP Softkey Menu Figure 5 1 DLP softkey menu 5 2 System Interface ...
Страница 65: ......
Страница 71: ......
Страница 85: ......
Страница 91: ...8 6 Customer Support ...
Страница 97: ......