53
multicast forwarding-table downstream-limit
Syntax
multicast forwarding-table downstream-limit
limit
undo multicast forwarding-table downstream-limit
View
System view
Default level
2: System level
Parameters
limit
: Specifies the maximum number of downstream nodes (the maximum number of outgoing interfaces)
for a single multicast forwarding entry. The value ranges from 0 to 128.
Description
Use
multicast forwarding-table downstream-limit
to configure the maximum number of downstream
nodes for a single entry in the multicast forwarding table.
Use
undo multicast forwarding-table downstream-limit
to restore the default.
By default, the maximum number of downstream nodes for a single multicast forwarding entry is 128.
Related commands:
display multicast forwarding-table
.
Examples
# Set the maximum number of downstream nodes for a single multicast forwarding entry to 120.
<Sysname> system-view
[Sysname] multicast forwarding-table downstream-limit 120
multicast forwarding-table route-limit
Syntax
multicast forwarding-table route-limit
limit
undo multicast forwarding-table route-limit
View
System view
Default level
2: System level
Parameters
limit
: Specifies the maximum number of entries in the multicast forwarding table. The value ranges from
0 to 2000.
Description
Use
multicast forwarding-table route-limit
to configure the maximum number of entries in the multicast
forwarding table.