P/N 480-0005-00-15
7-5
Chapter 7: System Alarms
Critical
Configuration Mismatch
A mismatch has occurred for the card in the slot and the
actual configuration. For example, this alarm would
occur if you insert a DSP card in a slot that has an earlier
configuration for a T1 card.
Critical
Operational Code Missing
Normal application code for T1/E1, System Controller,
CPU, or DSP card is damaged.
Critical
Configuration Data Missing
Configuration via CLI is missing. Check the configura-
tion data and add the necessary information.
Critical
Power Degrade
One power supply is not working correctly.
Critical
IVR Configuration Missing
Appears if an attempt to make an IVR call has been
made when a valid IP address is not configured.
If an IVR call has been passed through accidently, with-
out a real intention to use IVR for subsequent calls,
while both of the servers were disabled. In order to clear
the alarm, a user will have to change one of the IP
addresses to some value, and then disable it again.
Critical RADIUS
Configuration
Missing
Appears
when a RADIUS request is made and one or
more required configuration parameters are missing.
This alarm is cleared when the required RADIUS
parameters are configured via CLI.
Critical
RADIUS Server Not Responding
Appears when none of the configured RADIUS servers
respond.
This alarm is cleared when any of the RADIUS servers
responds or the RADIUS server is disabled via CLI.
Critical
IVR Configuration Missing
Appears if an attempt to make an IVR call has been
made while neither of the two IVR Prompt Server IP
addresses are set in the database; an IVR enabled trunk
group receives a call for which the IVR Prompt Server
IP is not configured.
If an IVR call has been passed through accidentally,
without a real intention to use IVR for subsequent calls,
while both of the servers were disabled. In order to clear
the alarm, a user will have to change one of the IP
addresses to some value, and then disable it again.
Major
Major Software Error
A software error has occurred that affects system signal-
ing, interfaces, or other major operation.
Severity
(appears as
part of severity
field)
Alarm Description
(text appears in desc field)
Definition
Содержание 480-0005-00-15
Страница 8: ...P N 480 0005 00 15 1 About this Guide ...
Страница 161: ...A 1 P N 480 0005 00 15 Appendix A Getting Acquainted with Tenor CMS in the VoIP Network ...
Страница 168: ...B 1 P N 480 0005 00 15 Appendix B Specifications Approvals ...
Страница 171: ...B 4 P N 480 0005 00 15 Appendix B Specifications Approvals Storage Temperature 14 to 140 F 10 to 60 C ...