If you detect a smell of gas, please
close the main gas cock before the
gas meter immediately and call the
emergency service of your gas supply
authority.

To ensure that no toxic flue gases occur, the combustion
air must flow unobstructed to the gas boiler. Therefore,
with room air dependent operation, the air inlet openings
(e.g. cellar window) must never be closed. The boiler
itself must also never be closed off.

Keep the room in which your boiler is installed clean
and before cleaning, switch off the burner as dust
laden combustion air can lead to faults.

Faults

For your safety the burner shuts down automatically in
the case of faults in the burner system, if the gas
pressure is too low, if gas is absent or if the maximum
permissible boiler temperature is exceeded. Wait about
5 minutes before attempting to place the burner back
in operation, by actuating the reset button on the boiler
control panel. If this is not successful, please close the
gas cock and call your after-sales service or heating
installer.

Absolutely imperative!

Fault-free function is only guaranteed

if the operating instructions are
complied with and both boiler and
burner are regularly maintained by a
specialist.

Faults and damage caused by installing in unsuitable
rooms, e.g. hobby rooms, workshops etc., also by
contaminated operating media (gas, water, combustion
air), unsuitable chemical additives to the heating water,
incorrect handling, faulty installation and damage due
to the exercising of force are not covered by our
guarantee; this also applies to corrosion due to halo-
gen compounds, e.g. from spraycans, paints,
adhesives, solvents and cleaning agents.

Important information

Important information

Installation and assembly instructions

• The installer has handed you the installation and

assembly instructions. Keep these important
documents carefully so that where necessary the
after-sales service can obtain technical information
on-site.

Содержание UltraGas AM condens (50-350)

Страница 1: ...Liquid gas Heating pump type Heating controller type Mixer type Separate calorifier type Calorifier sensor Thermostat Outside temperature sensor Room temperatur sensor Combustion air supply Room Outs...

Страница 2: ...operation of your Hoval UltraGasAMcondens allapplicablelaws regulations and standards must be complied with in particular the regulations of the responsible energy supply authorities In the case of qu...

Страница 3: ...eating controller If the boiler is also used for water heating it remains switched on for the whole year Fuel The boiler is only to be operated with the type of gas stated on the rating plate Settings...

Страница 4: ...e reset button on the boiler control panel If this is not successful please close the gas cock and call your after sales service or heating installer Absolutely imperative Fault freefunctionisonlyguar...

Страница 5: ...ed boiler temperature at the boiler temperature controller Please refer to the section Faults on page 4 if fault lamps light Placing out of operation Place the main SYSTEM switch to 0 Close the gas sh...

Страница 6: ...ng nor mal Check 6 3A fuse if all displays remain dark Controls the internal boiler functions Settings and changes are only to be made by the heating specialist The indication flashes if a fault is pr...

Страница 7: ...ting Automatic control corresponding to the switching times entered for the 3 nd program longer operating time The room temperature is not reduced in the night Hot water according to clock program 2 S...

Страница 8: ...to safely break the connection Note the water quality Drinking water quality the pH value must not exceed 9 5 Fill with water slowly check the water level at the hydrometer or pressure gauge Keep the...

Страница 9: ...urn open Is the main switch in the Changeover 6 OFF position Is the clock of the TopTronic Carry out check according to the separate operating correctly set instructions for the heating controller Che...

Страница 10: ...oors and windows closed in the winter Close flue flaps when the fire is out Use kitchen and bathroom fans only when steam and odours have to be extracted Ventilate for short periods but frequently Sea...

Страница 11: ...d set up for optimal operation Any repairs will be carried out at once with your agreement Amaintenancecontractcarriesawiderange of benefits Your guarantee period is extended when you take out a maint...

Страница 12: ...p Tel 031 818 66 30 Fax 031 818 66 31 kc bern hoval ch Z rich Postfach 8706 Feldmeilen Tel 0848 81 19 30 Fax 0848 81 19 31 kc zuerich hoval ch Zentralschweiz Postfach 8706 Feldmeilen Tel 0848 81 19 40...

Отзывы: