Legend

Function

 

The boiler operating elements

6. Setpoint setting

”reduced”

7. Program switch

8. Interrogation and

programming level

9. Display field

10. Operating instructions

11. Room station

- The desired room temperature for the night can be set here.

Middle setting 14

°

±

6

°

C

The heating program can be selected here:

Heating and hot water filling ”OFF”.
Frost protection guaranteed

The room temperature set for the night is also effective
during the day
Hot water according to clock program 2

Automatic control corresponding to the switching times
entered for the 1

st

 program

(interim reduction for the day)

Automatic control corresponding to the switching times
entered for the 2

nd

 program

(normal setting)

Automatic control corresponding to the switching times
entered for the 3

nd

 program

(longer operating time)

The room temperature is not reduced in the night
Hot water according to clock program 2

Summer operation: Heating ”OFF”
Frost protection, hot water filling is effective according to
clock program 2

Manual operation for the specialist. Burner and
circulation pump in operation. No supply to the mixer
valve, hot water filling in operation

Settings such as time of day and values can be interrogated here.
Setting according to special operating instructions.

Displayed here are the current time, boiler temperature and where
applicable the calorifier temperature.

Quick-reference operating instructions for heating controller only (4)

Optional
Permits operation of the heating controller (4) in the living room. If a
room station is connected, settings 5-6-7 are replaced by the settings
at the room station

3

2

1

Содержание UltraGas AM condens (50-350)

Страница 1: ...Liquid gas Heating pump type Heating controller type Mixer type Separate calorifier type Calorifier sensor Thermostat Outside temperature sensor Room temperatur sensor Combustion air supply Room Outs...

Страница 2: ...operation of your Hoval UltraGasAMcondens allapplicablelaws regulations and standards must be complied with in particular the regulations of the responsible energy supply authorities In the case of qu...

Страница 3: ...eating controller If the boiler is also used for water heating it remains switched on for the whole year Fuel The boiler is only to be operated with the type of gas stated on the rating plate Settings...

Страница 4: ...e reset button on the boiler control panel If this is not successful please close the gas cock and call your after sales service or heating installer Absolutely imperative Fault freefunctionisonlyguar...

Страница 5: ...ed boiler temperature at the boiler temperature controller Please refer to the section Faults on page 4 if fault lamps light Placing out of operation Place the main SYSTEM switch to 0 Close the gas sh...

Страница 6: ...ng nor mal Check 6 3A fuse if all displays remain dark Controls the internal boiler functions Settings and changes are only to be made by the heating specialist The indication flashes if a fault is pr...

Страница 7: ...ting Automatic control corresponding to the switching times entered for the 3 nd program longer operating time The room temperature is not reduced in the night Hot water according to clock program 2 S...

Страница 8: ...to safely break the connection Note the water quality Drinking water quality the pH value must not exceed 9 5 Fill with water slowly check the water level at the hydrometer or pressure gauge Keep the...

Страница 9: ...urn open Is the main switch in the Changeover 6 OFF position Is the clock of the TopTronic Carry out check according to the separate operating correctly set instructions for the heating controller Che...

Страница 10: ...oors and windows closed in the winter Close flue flaps when the fire is out Use kitchen and bathroom fans only when steam and odours have to be extracted Ventilate for short periods but frequently Sea...

Страница 11: ...d set up for optimal operation Any repairs will be carried out at once with your agreement Amaintenancecontractcarriesawiderange of benefits Your guarantee period is extended when you take out a maint...

Страница 12: ...p Tel 031 818 66 30 Fax 031 818 66 31 kc bern hoval ch Z rich Postfach 8706 Feldmeilen Tel 0848 81 19 30 Fax 0848 81 19 31 kc zuerich hoval ch Zentralschweiz Postfach 8706 Feldmeilen Tel 0848 81 19 40...

Отзывы: