Hoval UltraGas AM condens (50-350) Скачать руководство пользователя страница 6

    4 200 191 / 01

6

The boiler operating elementsls

0

I

ON
Boiler in operation

SYSTEM

OFF
Boiler & burner are
inoperative

Attention:

No frost protection

SYSTEM

I

Legend

Function

2

6

7

5

8

1

3

10

11

4

9

Operating elements

1. Operating mode

selector

ON/OFF

2. Fuse

3. Basic control

4. Electronic heating

controller

5. Setpoint setting ”nor-

mal”

Check 6.3A fuse if all displays remain dark.

- Controls the internal boiler functions

Settings and changes are only to be made by  the heating specialist.
The indication flashes if a fault is present. To reset, fold down the
cover and press the reset button.

- Provides for the correct room temperature according to the

outside temperature.

- Controls the heating up of the calorifier etc.

Special instructions are supplied with the heating
controller.

- Middle setting 20

°

C

Here the room temperature can be changed by 

±

8

°

C

Содержание UltraGas AM condens (50-350)

Страница 1: ...Liquid gas Heating pump type Heating controller type Mixer type Separate calorifier type Calorifier sensor Thermostat Outside temperature sensor Room temperatur sensor Combustion air supply Room Outs...

Страница 2: ...operation of your Hoval UltraGasAMcondens allapplicablelaws regulations and standards must be complied with in particular the regulations of the responsible energy supply authorities In the case of qu...

Страница 3: ...eating controller If the boiler is also used for water heating it remains switched on for the whole year Fuel The boiler is only to be operated with the type of gas stated on the rating plate Settings...

Страница 4: ...e reset button on the boiler control panel If this is not successful please close the gas cock and call your after sales service or heating installer Absolutely imperative Fault freefunctionisonlyguar...

Страница 5: ...ed boiler temperature at the boiler temperature controller Please refer to the section Faults on page 4 if fault lamps light Placing out of operation Place the main SYSTEM switch to 0 Close the gas sh...

Страница 6: ...ng nor mal Check 6 3A fuse if all displays remain dark Controls the internal boiler functions Settings and changes are only to be made by the heating specialist The indication flashes if a fault is pr...

Страница 7: ...ting Automatic control corresponding to the switching times entered for the 3 nd program longer operating time The room temperature is not reduced in the night Hot water according to clock program 2 S...

Страница 8: ...to safely break the connection Note the water quality Drinking water quality the pH value must not exceed 9 5 Fill with water slowly check the water level at the hydrometer or pressure gauge Keep the...

Страница 9: ...urn open Is the main switch in the Changeover 6 OFF position Is the clock of the TopTronic Carry out check according to the separate operating correctly set instructions for the heating controller Che...

Страница 10: ...oors and windows closed in the winter Close flue flaps when the fire is out Use kitchen and bathroom fans only when steam and odours have to be extracted Ventilate for short periods but frequently Sea...

Страница 11: ...d set up for optimal operation Any repairs will be carried out at once with your agreement Amaintenancecontractcarriesawiderange of benefits Your guarantee period is extended when you take out a maint...

Страница 12: ...p Tel 031 818 66 30 Fax 031 818 66 31 kc bern hoval ch Z rich Postfach 8706 Feldmeilen Tel 0848 81 19 30 Fax 0848 81 19 31 kc zuerich hoval ch Zentralschweiz Postfach 8706 Feldmeilen Tel 0848 81 19 40...

Отзывы: