12
Advanced User Instructions
430293ENG-Dec01
Room temperature correction for PARTY and
HEATING with variable temperature
parameter enabled.
For operating types:
-
PARTY
-
HEATING
The room temperature is set to automatic works
setting of 20ºC or the corrected value which has
been set in the user level.
The actual room temperature values for each of
these two operating types can be set
independently to the automatic program if the
relevant parameter has been enabled in the
service level by an engineer.
The value is set separately when calling up the
operating type PARTY or HEATING by using
the and keys. These values remain
stored for each further call of this operating
type.
Room temperature correction during
automatic with variable temperature
parameter enabled.
During automatic operation the room
temperature can be corrected using the
and keys. The value can also be corrected
for PARTY or HEATING operation by pressing
the key and for REDUCED operation by
pressing the key.
Entering the time clock level
Entering this level is achieved by simply pressing
the key. Initially the heating cycle which the
room station has been set to is shown. The three
programs 1, 2 or 3 can be selected using the
and keys.
Press key
Boiler circuit
Works setting: 2
Change with
and
keys
or (if present)
Mixer circuit 1
Works setting: 2
Change with
and
keys
or (if present)
Mixer circuit 2
Works setting: 2
Change with
and
keys
With the and keys all of the heating
circuits together with the hot water circuit can be
called up and are available for programming.
Time Clock Programming
It is possible to program up to three cycles
periods for each desired weekday. Each of these
cycles has an on / off as well as a temperature
indication for this time span. The temperature
can only be adjusted if the relevant parameter is
enabled in the service level.
The temperature indication refers to the heating
cycle. The temperature between heating cycles
is controlled according to the setting at the
central unit.
For the hot water programs the temperature
indication refers to the hot water temperature.
Calling up of heating cycles
With a further pressing of the key the first
heating cycle of the selected program shows
complete with indication of weekday, cycle
number, on time, off time and temperature. Each
value is called up with the key in series
-
On time
-
Off time
-
Temperature
The key can be used to step backwards.
The current value which can be changed with
the and keys is shown blinking. Switch
times can be altered in 5 minute intervals and
temperatures in 0.5K increments in the range of
5-30ºC.
The next heating cycle can be called up by
pressing the key and the process repeated.
Note: The on/off times of not used heating cycles
should be set to 00:00 by simultaneously
pressing the and keys.
The 00:00 value does
not
refer to a clock
time but only shows an undefined switch
time.