1 A combined draught stabiliser and pressure relief damper is provided with each BioLyt boiler for fitting by the installer.
2
Min. 13 A
protection because of operating current.
Technical Data
BioLyt
Type
(50)
(70)
(110)
(130)
(160)
• Nominal output
kW
49
69
105
130
156
• Heat input at nominal output
kW
54
74
114
141
170
• Heat output range
kW
14-49
20-69
31-105
39-130
43-156
• Pellets
Ø
mm
6-8
6-8
6-8
6-8
6-8
Length
mm
5-30
5-30
5-30
5-30
5-30
• Maximum boiler flow temperature
°C
80
80
80
80
80
• Minimum boiler operating temperature
°C
60
60
60
60
60
• Minimum boiler return temperature
°C
45
45
45
45
45
• Flue gas temperature at nominal output
°C
170
170
160
170
185
• Flue gas temperature at minimum output
°C
90
90
80
90
100
• Carbon dioxide CO
2
%
12
12
12
12
12
• Operating-/test pressure
bar
3,0/4,5
3,0/4,5
3,0/4,5
3,0/4,5
3.0/4.5
• Minimum operating pressure
bar
1.0
1.0
1.0
1.0
1.0
• Boiler efficiency at nominal output
% net
> 90
> 90
>90
>90
>90
• Flue gas mass flow rate at nominal output
(based on moisture content of pellets 10 %)
kg/h
120
170
260
320
375
• Flue gas mass flow rate at minimum output
kg/h
38
53
82
98
112
• Flow resistance
z-value
1.5
1.5
0.3
0.3
0.3
• Boiler waterside resistance at 10 K ∆T
mbar
25
55
24
39
52
• Boiler waterside resistance at 20 K ∆T
mbar
7
16
6
10
13
• Water flow at 10 K ∆T
m³/h
4.2
6.4
9.1
11.5
13.5
• Water flow at 20 K ∆T
m³/h
2.1
3.2
4.5
5.7
6.7
• Boiler water content
Litre
180
215
360
360
360
• Fuel-loading chamber capacity
Litre
200
200
200
200
200
• Ash bin capacity
Litre
65
65
180
180
180
• Thickness of boiler body insulation
mm
80
80
80
80
80
• Boiler dry weight
(
without
lagging, burner, pellets hopper)
kg
390
520
980
980
980
• Boiler dry weight
(
with
lagging, burner, pellets hopper)
kg
640
780
1350
1350
1350
Thermal flow safeguard
• Switching point of thermal flow safeguard
°C
95
95
95
95
95
• Minimal flow of water
(cold water 10 °C)
m³/h
2.0
2.0
2.0
2.0
2.0
• Minimum required cold water flow pressure
bar
2
2
2
2
2
Flue system
1
• Negative pressure condition at boiler flue outlet
-Pa
5 to 20
5 to 20
5 to 20
5 to 20
5 to 20
• Electrical consumption during operation
Watt
170
170
350
380
400
• Electrical consumption during ignition
Watt
1800
1800
1950
1950
1950
• Electrical consumption during introduction of pellets
Watt
1900
1900
1900
1900
1900
• Maximum current
2
A
13
13
13
13
13
Pellet transportation system basis kit RAS41 (BioLyt 50 & 70 only)
Delivery tube length [m]
maximum delivery tube lift [m]
15 to 25
1,8
10 to 15
2,8
5 to 10
4,5
2
Hoval BioLyt (50-160)