OPERATION
Normal Mode
In standby condition the TEST/HUSH indicator flashes every 344 seconds to
indicate that the smoke alarm is operating properly. The smoke alarm detects
smoke every 10 seconds. When it senses smoke, the alarm sounds and the TEST/
HUSH indicator flashes red at the same time, until the air is clear.
Pause mode (Low sensitivity)
The smoke alarm is desensitized by pushing the TEST/HUSH button. The alarm
indicator flashes every 10 seconds and no audible sound will be heard during 9
minutes, unless smoke becomes denser. If the smoke becomes denser, the alarm
will override the pause mode. The pause mode will end automatically after 9
minutes or by pressing the TEST/HUSH button again.
Low battery warning
The low battery warning will indicate when the voltage is too low, the smoke
alarm will then make short beeps every 43 seconds.
Test mode
By pressing the TEST button the smoke alarm will enter alarm mode. The unit will
make beeps every 0,5 second and the TEST/HUSH indicator will flash red.
Alarm Memory
This smoke alarm is equipped with an alarm memory, which provides a visual
indication when an alarm has been activated. When the TEST/HUSH button
indicator flashes green 3 times every 43 seconds, that means alarm has been
made during the last 24 hours. Please check if there is fire risk in detection
area. This indication will end after 24 hours or when pushing Test/Hush button.
First time you press test/mute button after alarm is made, the smoke alarm will
indicate by special alarm mode.