16
Operations
Operations Instructions
Before Starting
1.
Read all manuals provided with this pressure
washer. Become familiar with location and function
of all operating and safety controls.
DANGER: Improper wiring connections of the
equipment can result in a risk of electrocution.
Check with a qualified electrician or service
personnel if you are in doubt as to whether the
outlet is properly grounded.
WARNING: Check hoses, fittings, wand, trigger gun
and fuel connections daily for signs of wear, cracks
and looseness, and replace as required.
2.
Connect water supply hose to the standard garden
hose connector. The water faucet and supply hose
must be capable of providing 4.0 GPM.
3.
Fill oil burner fuel tank. Use kerosene, #1 grade
home heating oil, #1 or #2 diesel fuel.
IMPORTANT: Do not use gasoline, crankcase
draining, used oil or oil containing gasoline or
solvents.
NE PAS UTILISER D’ESSENCE, DE PRODUITS DE
VIDANGE NI D’HUILE CONTENANT DE L’ESSENCE
OU DES SOLVENTS.
4.
Check pump oil level.
5.
If detergents are to be used, only use detergents
intended for pressure washers. Follow instructions
on the detergent container.
I
MPORTANT: Before installing pressure nozzle on
initial start-up, turn on the water supply, start the
pump by pressing the pump ON switch, and hold
the trigger gun open until water appears at the end
of the wand. Allow water to run from the end of the
wand until clear to prevent the nozzle from
clogging.
IMPORTANT: If the pressure washer has not been
used for an extended period of time, remove the
pressure nozzle from the end of the wand and turn
on water supply, and start the pump by pressing
the pump ON switch. Hold the trigger gun open and
allow water to run from the end of the wand until
clear.
6.
Install the pressure nozzle on end of wand
.
I
MPORTANT: The trigger gun provided with this
pressure washer is equipped with a manual trigger
lock to prevent accidental operation of the trigger
gun. The trigger lock should be used whenever the
trigger gun is not in use.
To Start
WARNING: Risk of injection or severe injury - Keep
clear of nozzle - DO NOT direct discharge stream at
persons - This machine is to be used only by
qualified operators.
AVERTISSEMENT: RISQUE D’INJECTION ET DE
BLESSURES GRAVES. SE TENIR À L’ÉCART DU
JET. NE PAS DIRIGER LE JET DE SORTIE VERS
D’AUTRES PERSONNES. CONFIER L’UTILISATION
DE CE MATÉRIEL À UN OPÉRATEUR QUALIFIÉ.
WARNING: Wear eye, ear, hand, foot and skin
protection at all times while operating pressure
washer.
WARNING: Before changing pressure nozzle,
engage manual trigger gun lock.
IMPORTANT: The water must be turned on before
starting. Running the pump dry will cause damage
and void warranty.
IMPORTANT: Do not allow the machine to run with
trigger of the trigger gun released for more than
10 minutes at any one time or damage to pump may
occur.
1.
If equipped with a GFCI, test the GFCI using the
reset and test procedures provided on the GFCI
device. The GFCI must be tested with every use.
2.
Turn ON water supply.
3.
Hold wand firmly, release trigger of trigger gun and
turn pump switch ON. Squeeze trigger of trigger
gun and allow air to purge from system.
Hotsy 800 OIL FIRED OPERATOR’S 8.921-206.0 - B
Pre
ss
ure Nozzle
Manual Trigger Lock