background image

Features & Settings

Output Level:

The ACE system cleans the water throughout the day. The output setting of 0 -10 de-

termines how long the cell runs each day. Observe your usage patterns and measure 

the chlorine level before each use to guide your output setting. Adjust output up or 

down to increase or decrease output. Keep your setting as low as possible to main-

tain 1-5 pm chlorine. Use Boost or add Freshwater Concentrated Chlorine Granules 

for occasional high use situations.  

Output Settings

 

0  

No output/System off

 

Vacation/low output mode

 

2-7 

Normal use settings (recommended)

 

8-9 

High use settings 

 

10 

Maximum system output, equal to Boost (system runs constantly)

Turning the ACE System off

 

By setting Output to 0, the system will stop generating sanitizers. You will need to 

manually maintain the sanitizer level using FreshWater Concentrated Chlorinated 

Granules if the ACE system is off. 

Vacation or limited use

When the spa is not going to be in use, shock the spa by increasing chlorine to 3-5 

ppm and then run the automatic clean cycle. Clean or replace filters. Lower Output to 

2. For extended vacations, lower Output  to 1 for low output mode. 

Boost:

The Boost feature temporarily increases the output setting to the maximum level for 

24 hours.  The system returns to the previous output setting once the Boost cycle is 

over. Use the Boost function to gradually increase the chlorine level prior to a high 

use situation, or anytime the chlorine level is below 1-5 ppm.  
A Boost will have a greater impact when the output setting is set to a low level, and 

less of an impact when the output setting is high. Freshwater Concentrated Chlorine 

Granules can be added to create an immediate chlorine residual to remove bather 

load and assist the ACE system in building a sanitizer residual.

To increase the chlorine level:

1.  In the ACE Menu, press the 

ON

 ▲

 button to enter the BOOST menu. 

2.  Press the 

OFF

 ▼

 button twice to select and confirm the boost. The BOOST 

icon will flash to indicate that the setting has been updated.  The system 

will automatically initiate a salt test before the boost cycle.  Once the test is 

complete (up to 20 seconds) the bOOST screen will flash to indicate that the 

system is boosting. 

Page 6

 

                  ACE Salt Water Sanitizing System

Содержание LIMELIGHT COLLECTION Ace

Страница 1: ...L I M E L I G H T C O L L E C T I O N A C E O W N E R S M A N U A L...

Страница 2: ...stem The system is sized for the typical user Heavy users may need to supplement sanitizer generation with dichlor or MPS THE SPA OWNER IS ULTIMATELY RESPONSIBLE FOR MAINTAINING PROPER SANITARY WATER...

Страница 3: ...products are not recommended for use with ACE system Overview of the ACE System The ACE salt water sanitizing system features a diamond electrode cell that auto matically generates chlorine and mixed...

Страница 4: ...and the output level is not adjusted down the chlorine level may rise You can reduce the chlorine level in the spa water by adding hydrogen peroxide ACE System Status The ACE system communicates via...

Страница 5: ...OK ranges specified for the ACE system see table below and adjust as needed ACE System Parameter Target Min OK Range Max Salt 1750 ppm 1000 ppm 1750 ppm Hardness 50 ppm 25 ppm 75 ppm Alkalinity 80 ppm...

Страница 6: ...d adjust alkalinity pH and hardness as needed If hardness is still above 50 ppm use additional calcium removers at this time Test for chlorine The ACE system generates active oxygen that breaks down w...

Страница 7: ...needed or at least once every three months following instruction on the cell cleaning solution or cell cleaning bottle System Operation Access the ACE menu by pressing the MODE button several times f...

Страница 8: ...e automatic clean cycle Clean or replace filters Lower Output to 2 For extended vacations lower Output to 1 for low output mode Boost The Boost feature temporarily increases the output setting to the...

Страница 9: ...timer resets any time the output setting is adjusted If the output setting is not confirmed at the 30 day reminder the ACE system will automatically lower the output setting Day 30 Maintenance reminde...

Страница 10: ...Inspect cell for scale clean cell if needed Test water with salt test strips and add salt if needed Flashing icon and STAT 8 9 Non operational High salt level detected Correct salt level Clean Inspect...

Страница 11: ...lter standpipe Screw on the gray filter cap replace the filter lid and power up the spa Ensure that the cell is at the bottom of the filter standpipe by feeling for the pull of the pump s suction Trou...

Страница 12: ...ds low check for other conditions noted above 3 Verify chlorine level a Use a 5 way test strip to measure chlorine level If the test strip shows chlorine level is high above 5 ppm b Add 1 cup hydrogen...

Страница 13: ...chlorine in the water Check Output settings If you are using the spa heavily your use level may require you to increase the Output setting to a higher number Increase Salt Level Keep the salt level n...

Страница 14: ...lorine The chlorine reading on the test strip may not be indicative of total oxidizer level Ozone The ACE system should be capable of maintaining a sufficient sanitizer level and adding ozone is not r...

Страница 15: ...e clearly states that it is a replacement cell for the chlorine generating ACE device Follow all aspects of the local and National Electrical Code s when installing ACE Maximum spa water usage tempera...

Страница 16: ...98 6464 outside the USA or via e mail custsvc watkinsmfg com You must give Watkins and or your dealer written notice of any warranty claim along with a copy of your original purchase receipt indicatin...

Страница 17: ...limitation or exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you ANY IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY A...

Страница 18: ......

Страница 19: ......

Страница 20: ...t incurring any obligation Watkins Manufacturing Corporation 1280 Park Center Drive Vista California 92081 USA Part 302647 REV C 7 14 2014 Watkins Manufacturing Corporation ACE Hot Spring Limelight Fr...

Отзывы: