background image

Page 10

 

                      

ACE Salt Water Sanitizing System

NOTE: 

You may continue to use your spa as long as the chlorine level on the 

FreshWater 

®

 test strip is in the OK range.  Add granular chlorine as needed.

System Status Low (1-2):

The system status reading can be affected by cell age, scale build-up (dirty cell), cold 

water, high chlorine, dirty filters, or dirty water.

1.  Verify water temperature
 

a. 

The status reading will read lower in cooler water. To get an accurate   

 

 

status reading, ensure water is above 95° F

2.  Verify salt level 
 

a. 

Use a salt test strip to measure salt level. If the test strip shows salt    

 

 

level is low:

 

b. 

Add (1) cup of salt to the water and circulate for 5 minutes.

 

c. 

Retest with a salt test strip, and repeat until salt level reads in the OK    

   range
 

d. 

Run a manual status test to refresh. If System Status still reads low,    

 

 

check for other conditions noted above.

3.  Verify chlorine level
 

a. 

Use a 5-way test strip to measure chlorine level. If the test strip shows   

 

 

chlorine level is high (above 5 ppm):

 

b. 

Add 1 cup hydrogen peroxide with jets running. Check chlorine level    

 

 

after 10 minutes 

 

c. 

Retest with a test strip and repeat as needed

4.  Visually inspect and clean the cell
 

a. 

Follow the cell cleaning process to ensure that scale has not    

 

 

 

accumulated on the cell

 

b. 

Once the cell has been cleaned, replace the cell in the filter standpipe

 

c. 

Run a manual Status Test to refresh

5.  Visually inspect and clean filters (refer to spa owner’s manual).
6.  If the System Status message continues to read low, it may be an indication that 

it is time to replace the cell. 

System Status High (7-9):

If the Status indicator is in the red, this typically indicates that there is too much salt in 

the water. 
1.  If the status reading is less than halfway in the red:
 

a. 

Use a salt test strip to measure salt level. If the test strip shows salt    

 

 

level is high:

Содержание LIMELIGHT COLLECTION Ace

Страница 1: ...L I M E L I G H T C O L L E C T I O N A C E O W N E R S M A N U A L...

Страница 2: ...stem The system is sized for the typical user Heavy users may need to supplement sanitizer generation with dichlor or MPS THE SPA OWNER IS ULTIMATELY RESPONSIBLE FOR MAINTAINING PROPER SANITARY WATER...

Страница 3: ...products are not recommended for use with ACE system Overview of the ACE System The ACE salt water sanitizing system features a diamond electrode cell that auto matically generates chlorine and mixed...

Страница 4: ...and the output level is not adjusted down the chlorine level may rise You can reduce the chlorine level in the spa water by adding hydrogen peroxide ACE System Status The ACE system communicates via...

Страница 5: ...OK ranges specified for the ACE system see table below and adjust as needed ACE System Parameter Target Min OK Range Max Salt 1750 ppm 1000 ppm 1750 ppm Hardness 50 ppm 25 ppm 75 ppm Alkalinity 80 ppm...

Страница 6: ...d adjust alkalinity pH and hardness as needed If hardness is still above 50 ppm use additional calcium removers at this time Test for chlorine The ACE system generates active oxygen that breaks down w...

Страница 7: ...needed or at least once every three months following instruction on the cell cleaning solution or cell cleaning bottle System Operation Access the ACE menu by pressing the MODE button several times f...

Страница 8: ...e automatic clean cycle Clean or replace filters Lower Output to 2 For extended vacations lower Output to 1 for low output mode Boost The Boost feature temporarily increases the output setting to the...

Страница 9: ...timer resets any time the output setting is adjusted If the output setting is not confirmed at the 30 day reminder the ACE system will automatically lower the output setting Day 30 Maintenance reminde...

Страница 10: ...Inspect cell for scale clean cell if needed Test water with salt test strips and add salt if needed Flashing icon and STAT 8 9 Non operational High salt level detected Correct salt level Clean Inspect...

Страница 11: ...lter standpipe Screw on the gray filter cap replace the filter lid and power up the spa Ensure that the cell is at the bottom of the filter standpipe by feeling for the pull of the pump s suction Trou...

Страница 12: ...ds low check for other conditions noted above 3 Verify chlorine level a Use a 5 way test strip to measure chlorine level If the test strip shows chlorine level is high above 5 ppm b Add 1 cup hydrogen...

Страница 13: ...chlorine in the water Check Output settings If you are using the spa heavily your use level may require you to increase the Output setting to a higher number Increase Salt Level Keep the salt level n...

Страница 14: ...lorine The chlorine reading on the test strip may not be indicative of total oxidizer level Ozone The ACE system should be capable of maintaining a sufficient sanitizer level and adding ozone is not r...

Страница 15: ...e clearly states that it is a replacement cell for the chlorine generating ACE device Follow all aspects of the local and National Electrical Code s when installing ACE Maximum spa water usage tempera...

Страница 16: ...98 6464 outside the USA or via e mail custsvc watkinsmfg com You must give Watkins and or your dealer written notice of any warranty claim along with a copy of your original purchase receipt indicatin...

Страница 17: ...limitation or exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you ANY IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY A...

Страница 18: ......

Страница 19: ......

Страница 20: ...t incurring any obligation Watkins Manufacturing Corporation 1280 Park Center Drive Vista California 92081 USA Part 302647 REV C 7 14 2014 Watkins Manufacturing Corporation ACE Hot Spring Limelight Fr...

Отзывы: