background image

Prevent Cell Damage:

 NEVER insert anything into the cell or pressure wash it. This 

will damage the electrodes. 
1.  Turn off the power to the spa. Open the spa cover and remove the filter lid.
2.  Unscrew gray filter cap and gently pull the cell out of the filter.
3.  Inspect the cell for scale by looking between the electrodes.
4.  Unscrew the lid to the cleaning bottle included with the ACE® system and fill with 

spa water to the fill-line indicated on the bottle. Add 3 tablespoons of pH down to 

the cleaning bottle and secure lid. Shake bottle to create cleaning solution.

NOTE:

 A stronger cleaning solution of 1 pt muriatic pool acid & 10 pt water can be used 

as well as a commercial cell cleaner - follow directions on bottle.
5.  Remove the lid from the cleaning bottle. Place the cell in the bottle,  

ensuring that the bottom of cell is floating.

6.  Soak the cell for 10 minutes or until bubbles stop coming from the cell. If bubbles 

are still releasing from the cell after 10 minutes, continue soaking until the cell is 

clean and all scale is removed.

7.  Rinse cell and inspect for cleaning completion.
8.  Replace cell into the filter standpipe. Screw on the gray filter cap, replace the 

filter lid, and power up the spa. Ensure that the cell is at the bottom of the filter 

standpipe by feeling for the pull of the pump’s suction. 

Troubleshooting

Treating for Metals: 

High Metal content can cause staining and discolored water. It’s important that met-

als are removed before starting up the ACE system.
1.  Fill the spa with the Clean Screen

®

 pre-filter, ensuring that the valve is only 50% 

open (45° angle). 

2.  Ensure that there is no ozone unit installed and that the ACE system is turned off 

(Output level 0).

3.  Add FreshWater Stain & Scale metal control according to the instructions on the 

bottle.

4.  Place a Vanishing Act Calcium remover over the low speed jet suction.
5.  DO NOT add oxidizers (chlorine, ozone, ACE) for at least 24 hours.

Flashing On/Ready light and Water Care Icon

The green ON indicator light, in the Hot Spring logo on the front of your spa will 

slowly flash when the ACE system requires attention. The water care icon on the 

main control panel will also flash as an indication that some action is needed. Access 

the ACE system menu by pressing the 

MODE ▲

 

button several times from the home 

screen to reach the ACE menu. Press the 

ON ▲

 

button to enter the ACE system 

menu and review systme status messages.

 ACE Salt Water Sanitizing System 

                

Page 9 

Содержание LIMELIGHT COLLECTION Ace

Страница 1: ...L I M E L I G H T C O L L E C T I O N A C E O W N E R S M A N U A L...

Страница 2: ...stem The system is sized for the typical user Heavy users may need to supplement sanitizer generation with dichlor or MPS THE SPA OWNER IS ULTIMATELY RESPONSIBLE FOR MAINTAINING PROPER SANITARY WATER...

Страница 3: ...products are not recommended for use with ACE system Overview of the ACE System The ACE salt water sanitizing system features a diamond electrode cell that auto matically generates chlorine and mixed...

Страница 4: ...and the output level is not adjusted down the chlorine level may rise You can reduce the chlorine level in the spa water by adding hydrogen peroxide ACE System Status The ACE system communicates via...

Страница 5: ...OK ranges specified for the ACE system see table below and adjust as needed ACE System Parameter Target Min OK Range Max Salt 1750 ppm 1000 ppm 1750 ppm Hardness 50 ppm 25 ppm 75 ppm Alkalinity 80 ppm...

Страница 6: ...d adjust alkalinity pH and hardness as needed If hardness is still above 50 ppm use additional calcium removers at this time Test for chlorine The ACE system generates active oxygen that breaks down w...

Страница 7: ...needed or at least once every three months following instruction on the cell cleaning solution or cell cleaning bottle System Operation Access the ACE menu by pressing the MODE button several times f...

Страница 8: ...e automatic clean cycle Clean or replace filters Lower Output to 2 For extended vacations lower Output to 1 for low output mode Boost The Boost feature temporarily increases the output setting to the...

Страница 9: ...timer resets any time the output setting is adjusted If the output setting is not confirmed at the 30 day reminder the ACE system will automatically lower the output setting Day 30 Maintenance reminde...

Страница 10: ...Inspect cell for scale clean cell if needed Test water with salt test strips and add salt if needed Flashing icon and STAT 8 9 Non operational High salt level detected Correct salt level Clean Inspect...

Страница 11: ...lter standpipe Screw on the gray filter cap replace the filter lid and power up the spa Ensure that the cell is at the bottom of the filter standpipe by feeling for the pull of the pump s suction Trou...

Страница 12: ...ds low check for other conditions noted above 3 Verify chlorine level a Use a 5 way test strip to measure chlorine level If the test strip shows chlorine level is high above 5 ppm b Add 1 cup hydrogen...

Страница 13: ...chlorine in the water Check Output settings If you are using the spa heavily your use level may require you to increase the Output setting to a higher number Increase Salt Level Keep the salt level n...

Страница 14: ...lorine The chlorine reading on the test strip may not be indicative of total oxidizer level Ozone The ACE system should be capable of maintaining a sufficient sanitizer level and adding ozone is not r...

Страница 15: ...e clearly states that it is a replacement cell for the chlorine generating ACE device Follow all aspects of the local and National Electrical Code s when installing ACE Maximum spa water usage tempera...

Страница 16: ...98 6464 outside the USA or via e mail custsvc watkinsmfg com You must give Watkins and or your dealer written notice of any warranty claim along with a copy of your original purchase receipt indicatin...

Страница 17: ...limitation or exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you ANY IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY A...

Страница 18: ......

Страница 19: ......

Страница 20: ...t incurring any obligation Watkins Manufacturing Corporation 1280 Park Center Drive Vista California 92081 USA Part 302647 REV C 7 14 2014 Watkins Manufacturing Corporation ACE Hot Spring Limelight Fr...

Отзывы: