20 of 37
Indesit
Company
Service Manual UK
English
THE SANKYO ICEMAKER
HOW THE ICEMAKER WORKS
•
Water is automatically measured into the icemaker mould by the inlet solenoid water valve.
•
The Bi-metal thermostat mounted between the support housing and the mould detects the water /
ice temperature.
•
When the ice is cooled down to about - 9°C the thermostat switches the icemaker motor and the
icemaker heater ON.
•
The motor and the ejector blades begin to rotate.
•
Because the ice is frozen hard in the mould the motor will stall the ejector blades as they apply
pressure on the ice.
•
During the stall period the heater warms the mould to loosen the ice. This may take a few (up to
five) minutes.
•
When the ice is loose enough, the ejector blades and the motor will complete the rotation and eject
the ice from the mould.
•
The ice collects in the ice bucket below the icemaker.
•
The water inlet valve solenoid switches on again, to fill the mould with fresh water.
NOTE:
The Icemaker can only be checked with the 'Built-In Auto Test routine', see page 16.