FAULT CODES - Detailed
- Pressure switch faulty;
- Pressure switch tube damaged;
- Water in air trap;
- Air trap damaged.
- Tap closed or partially closed;
- Filler hose pinched;
- Filler hose
ſ
lter clogged/bent;
- Water pressure low or
ƀ
ow meter doesn’t work;
- Water solenoid valve faulty or disconnected.
- Turbine faulty or disconnected;
- Connector terminals not making contact;
- Turbine wiring faulty;
- Turbine faulty, disconnected or wet;
- WATER has been introduced manually;
- Filler hose
ſ
lter obstructed;
- Pressure switch faulty.
- NTC sensor bracket detached from bowl;
- Fault in electrical circuit of heating element;
- Heating element ITR incorrectly calibrated/faulty;
- Excessive suds;
- Heating element false contact
- NTC sensor incorrectly calibrated
- Lime scale on heating element.Water hardness
setting not compliant. User not putting in salt
- NTC sensor separated from socket (replaces
ſ
rst check)
- Heating element defective.
- Main board not programmed;
- Incorrect setting
ſ
le.
- Heating element cables disconnected;
- Main board relay defective
- Heating element defective;
- Main board relay defective.
- Fault in Main board/user interface wiring;
- Disconnect from electrical power supply.Wait 2
minutes. Reconnect appliance to power supply
and test again;
- User interface defective.
- Replace main board.
- Replace wash pump.
Pressure switch has not indicated
completion of fill, even though
turbine has filled appliance with
water correctly.
Maximum interval of time for com-
pletion of
ſ
ll has been exceeded.
Turbine has given no signal indicat-
ing entry of water, even though
ſ
ll
has effectively been completed.
Maximum interval of time for es-
tablishing temperature has been
exceeded (1 hour).
Software recognition error Proces-
sor not programmed.
HEATING ELEMENT CIRCUIT not
Note:
This code may display
during an Auto Test
If the dishwasher is working normally,
ignore this Fault Code during an Auto Test.
compliant (circuit open).
No communication/connection
between main board and user
interface.
Main board NOT WORKING
Reading between Wash pump and
Drain pump not consistent.
PRESSURE SWITCH
non compliant
WATER FILL
TIMEOUT
WATER TURBINE
damaged
TEMPERATURE
TIMEOUT (1 hour)
Software recogni-
tion error. Main
board not pro-
grammed
HEATING ELE-
MENT CIRCUIT not
compliant
Not Applicable
to this model
COMMUNICATION
error between main
board and display
Main board NOT
WORKING
VIRTUAL SENSOR
F05
F06
F07
F08
F09
F10
F11
F12
F13
F15
- Water leak;
- Float switch or wiring defective;
- New main board: Eeprom was programmed
off-site; to reset the alarm, switch off and switch
on again using the ON/OFF button.
- Fill solenoid valve failure;
- Main board
ſ
ll solenoid valve triac short-circuiting;
- Make certain drain hose is not on the
ƀ
oor.
- Drain pump blocked by foreign matter;
- Drain pump faulty/disconnected;
- Drain hose blocked;
- Drain trap blocked;
- Air bubble in hose;
- Check drain pump wiring and connectors at
component end and main board end;
- Check integrity of drain pump impeller;
- Replace drain pump.
- NTC sensor cables disconnected or damaged;
-Cablesorconnectorsdisconnectedorshort-circuiting;
- NTC sensor wet, short-circuit;
- NTC sensor damaged, open circuit.
Bowl
ƀ
oat microswitch electrical
circuit OPEN! (must be closed)
Fill valve admits water even when
deactivated.
Maximum drain time elapsed.
THERMISTOR (NTC) circuit not
compliant (break in continuity or
short-circuit)
FAULT
CODE
F01
ANTI-FLOODING
OVERFLOW
WATER FILL
SOLENOID VALVE
FAILURE
DRAIN TIMEOUT
THERMISTOR (NTC)
not compliant
NAME
POSSIBLE CAUSE
CHECKS
F02
F03
F04