Test Programme
A short test programme is available.
This test will display a previous fault code if there is one.
The test will check many of the components and filling and if faulty, will display a fault code quicker
than running a cycle.
It is useful for quickly checking several components, e.g. wash pump, fill valve, detergent solenoid,
regeneration valve and drain pump and also water levels.
Fault diagnosis could in many instances still be required.
To enter the Test Mode
Start with the appliance off and the door closed.
1.
Switch the dishwasher 'on' (On/Off button).
2.
Switch the dishwasher 'off' (On/Off button).
3.
Press the Start button and hold for 3 seconds.
4.
Switch the dishwasher 'on' (On/Off button).
5.
Press start.
When the Auto Test starts the last fault will be displayed for 15 seconds.
This will clear if the Auto Test is fully completed.
DEA601 Module - Auto Test Sequence
All times are approximate.
1.
Draining until the pressure switch is empty + 30 seconds.
2.
Static filling 3 litres of water (valve energised only).
3.
Dynamic filling 1 litre of water (valve + wash pump energised).
4.
Wash pump on for 60 seconds.
5.
Wash pump stops.
6.
Heater on for 10 seconds.
7.
Dispenser solenoid energised for 10 seconds.
8.
Wash pump on for 10 seconds.
9.
Regeneration valve on for 15 seconds (a slight hum will be heard).
10. Drain pump on until the pressure signals machine empty + 5 seconds.
11. Pause for 10 seconds.
12. Inlet solenoid valve and pump running simultaneously for 20 seconds.
13. Test cycle complete.
DEA602 Module - Auto Test Sequence