11 of 24
Indesit
Company
Service Manual UK
English
Rear Thermistor
Fitted to the heater assembly above the heater.
Used by the electronics for controlling the temperature into the rear of the dryer.
Front Thermistor
Fitted to the front air duct moulding Used by the electronics for controlling the temperature.
Safety Cut-Out (One Shot)
This device is a disc type thermostat set to operate at 150°C it is used as a safety device, It is
positioned above the element.
If the One-Shot Safety thermostat operates "open circuit", the dryer will be "dead".
No Fault Code will be displayed.
IF THIS DEVICE OPERATES, IT SHOULD BE REPLACED TOGETHER WITH THE CYCLING
THERMOSTAT (See next paragraph).
Cycling Thermostat
The cycling thermostat is mounted adjacent to the safety cut-out, is designed to open at 120°C it limits
the temperature of the heat entering the drum.
NOTE: -
The safety cut-out and cycling thermostat are fitted as safety devices and under normal
operating conditions have no effect on the air temperature entering the drum.
Motor
A two pole P.S.C running at 2800 rpm with the impeller fitted to the rear end of the shaft and the drive
belt running directly in grooves in the front end of the shaft. It is protected from overload by a
self-resetting internal cut-out which interrupts the electrical supply to the windings.
It is used together with a capacitor that is mounted on the base of the dryer.
Drum Rear Seal
This unit comprises of a ring of foam with a webbing bearing face. Lubrication is applied to the drum
where the webbing surface runs, to reduce noise and wear. The seal reduces air losses at the rear of
the drum. The joints in the foam are sealed with glue and the joints in the webbing are stitched to
further reduce air leakage.
Door Operation
Opening the door (or pressing the START/PAUSE button) during a programme will stop the dryer and
have the following effects:
•
The START/PAUSE light flashes Amber.
•
During a delay phase the delay will continue to count down. The START/PAUSE button
must
be
pressed to resume the delay programme. The progress lights will change to show current status.
•
During the drying part of the programme, the time to end count continues but the colons do not
flash. The START/PAUSE button
must
be pressed to resume the programme. The progress lights
will change to show the current status.