1
2
Use only parts approved by the manufacturer!
3
4
5a
6
5b
19
Figure 11. Reset button of the overheat
protector
Do not install the temperature sensor
closer than 3’ 3-3/8” to an air vent. This
air flow near an air vent cools down
the sensor, which gives inaccurate
temperature readings to the control unit.
As a result, the heater might overheat.
See figure 10.
SPARE PARTS
Use only parts approved by the manufacturer!
1
Control panel
2
Data cable 50’
3
Temperature sensor, 50’
4
Circuit board
5a Contactor 30 A (HeatPad10/CX30-U1-U3)
5b Contactor 45 A (HeatPad15/CX45-U1-U3)
6
Multidrive cable 5’ (optional)
MAINTENANCE INSTRUCTIONS
1. All service operations must be done by professional licensed maintenance personnel.
Control unit should NOT be opened by unlicensed personnel.
2. Wipe dust and dirt from the power unit and the control panel with a damp cloth. DO
NOT use running water!
3. Prevent any water from going inside the power unit at anytime.
4. The control panel is splashproof.