Look for the important additional instructions
in the manual! / Consultez les instructions
supplémentaires importantes dans le manuel!
B
A
A
A
A
A
A
inch
mm
A
2
50
B
42
1060
*Q = includes built-in contactor / contient le contacteur integré
AN INADEQUATELY FILLED ROCK SPACE CAUSES FIRE RISK.
IL Y A UN RISQUE D'INCENDIE SI LE RÉCIPIENT À PIERRES N’EST PAS CORRECTEMENT REMPLI.
DO NOT PLACE ANY OBJECTS ON HEATER. COVERING CAUSES FIRE RISK.
NE PAS PLACER DES OBJETS AU-DESSUS DU POÊLE. IL Y A UN RISQUE D'INCENDIE SI LE POÊLE EST RECOUVERT.
WARNING! AVERTISSEMENT!
FOR SUPPLY CONNECTIONS USE COPPER
WIRE ONLY SUITABLE FOR AT LEAST 90 ºC
POUR LES CONNEXIONS ELECTRIQUES PREVOIR
UN CABLAGE RESISTANT AU MOINS A 90° C
For AC only /
Pour courant alternatif seulement (AC)
Control units / Centres de contrôle:
CX30-U1-U3 / CX45-U1-U3 / CX-170-U1 /
CX-170-U1-15 / CX-170-U3 / CX-170-U3-15
IPX4
3159549
MODEL
MODÈLE
*Q
POWER
PUISSANCE
VOLTAGE
TENSION
PHASE
SUPPLY
WIRES
TENSION
DE
SERVICE
FLOOR AREA
SURFACE DE
PLANCHER
CONTROL UNIT
GRADE SETTINGS
PARAMÈTRES
DE CONTRÔLE
DE QUALITÉ DE
L’UNITÉ
MIN.
SQ.FT
MAX.
SQ.FT
HL(S)7U1(Q)
6,8 kW
240
1
10
28
57
HL(S)9U1(Q)
9,0 kW
240
1
8
45
79
HL(S)11U1(Q)
10,5 kW
240
1
6
22
98
HL(S)7U3(Q)
6,8 kW
208
3
12
28
57
HL(S)9U3(Q)
9,0 kW
208
3
10
45
79
HL(S)11U3(Q)
10,5 kW
208
3
8
22
98
C2
C2
C1
C2
C2
C1
ETL LISTED
CONFORMS TO
UL STD 875
CERTIFIED TO
CAN/CS A STD
E60335-2-53-05
10
Table 3b. Changing the heater grade (See Section 2.1.)
* Factory Setting
TYPE LABEL
CONTROL UNIT GRADE SETTINGS
C2
(FOR EXAMPLE)
All heater grades:
A1, A2, A3, A4, A5
B1 (default), B2, B3, B4, B5
C1, C2, C3, C4, C5
D1, D2, D3, D4, D5
E1, E2, E3, E4, E5, E6
Heater grade
Heater grade can be changed with the - and + buttons. See the right grade from the
heater’s type label, under “control unit grade settings”.
Press the MENU button to accept the set. Press the MENU button again and the next
set will appear.
Sauna dehumidifying interval
The sauna dehumidifying interval turns the fan on (IF installed / accessory) and dries
out the sauna room to keep it in a good condition. The sauna dehumidifying interval
can be turned ON or OFF*). The interval will begin when the devices are switched off
from the I/O buttons or when the set on-time runs out. The length of the interval is
45-minutes. When the time runs out, the fan turns off automatically. The interval can
also be stopped manually at any time by pressing the I/O button.
Press the MENU button to accept the set. Press the MENU button again and the next
set will appear or the control unit switches to standby mode.