background image

3

115mm

154mm

275mm

Pilot Hole Locations

154mm

Hook

Bracket (B)

Wall

Wood Screw

Screw

(two on left)

Screw

(one on right)

Stand

Mounting Hole

(four)

[c] MOUNTING

* Make pilot holes in the wall as shown below.

* Hook the back of the unit on the bracket (B).

[d] STAND (OPTION)

Install the unit by using the optional stand and the three screws 

provided on the unit.

If necessary, secure the stand with screws and the four mounting 

holes provided.

4. ELECTRICAL CONNECTIONS

WARNING

1. The connections must be made to a separate power supply 

or receptacle. Branching off the power cord, using an 

extension cord, or sharing a single power supply with other 

appliances may result in electric shock, heat generation, fire 

or malfunction.

2. This product must be earthed. Do not connect the earth wire 

to a gas line, water line, lightning rod or telephone earth wire. 

Improper earth may cause electric shock.

CAUTION

The maximum allowable voltage variation should not exceed 

±10 percent of the rated voltage. Operation of the unit outside 

of this range may cause smoking, ignition, damage to the unit 

or reduction of the performance.

5. PLUMBING

[a] PLUMBING MATERIALS

* The water supply line should be a flexible, rigid PVC, or rigid PVC 

lined steel pipe in compliance with the applicable water quality 

standards.

* Clean the pipes thoroughly before connections to remove shavings, 

cutting oils, or other foreign matter that may clog the dual check 

valve, pressure reducing valve or water valve.

* Use sealants, sealing tapes, or gaskets to have leak free joints. Do 

not use a sealant that can clog pipes or leave odor in water.

[b] WATER SUPPLY LINE

IMPORTANT

1. Use potable water only. Use of non-potable water may cause 

corrosion, clogged pipes, or health problems.

2. The water supply pressure must be within 0.1 to 0.75 MPa 

(100 to 750 kPa).

3. Depending on water quality, even potable water may cause 

scaling inside the water circuit, resulting in failure.

4. Installation of a water treatment device may be required in 

some water conditions. Consult a water treatment specialist 

or an authorized Hoshizaki service company.

5. Be sure to use the new hose-sets supplied with the 

appliance. Do not reuse any old hose-sets.

[c] DRAIN LINE

WARNING

The unit must dispense and drain water into the same sink. 

Otherwise, hydrogen gas or chlorine gas may cause health 

problems, or the water pipes may corrode, resulting in water 

leaks.

IMPORTANT

The drain hoses should be as short and straight as possible. 

Always keep the drain hose ends at least 5 cm above the sink 

drain outlet.

Connection of the water supply to the HOSHIZAKI water electrolyzer 

shall be undertaken in accordance with AS/NZS 3500.1.

Note: Make proper connections to prevent water leaks, resulting in 

damage to surrounding property. The plumbing materials must 

be prepared on site.

 

Be sure to install a pressure reducing valve 

to prevent possible water leaks.

[d] VENT LINE

WARNING

Ensure adequate ventilation. Hydrogen gas or chlorine gas 

may cause health problems.

IMPORTANT

1. Ventilate the installation site (minimum air flow: 450m

3

/h) to 

control chlorine concentration below the maximum level of 0.1 

ppm.

2. A ventilation fan, if used, must have at least 15 cm of fan 

blade diameter and must be corrosion resistant and installed 

close to the unit.

3. Keep gas pipes or corrosive materials away from the air 

duct.

4. Do not locate the air duct outlet near a source of ignition.

Содержание WOX-40WA-EW

Страница 1: ...FOR QUALIFIED INSTALLER ONLY WOX 40WA EW WATER ELECTROLYZER INSTALLATION MANUAL L2X006112 111520 3 16 Minamiyakata Sakae cho Toyoake Aichi 470 1194 Japan...

Страница 2: ...r sanitizing and cleaning water lines Hydrogen gas or chlorine gas may cause health problems 1 CONSTRUCTION a EXTERIOR 7 Drain outlet left Drains sanitizing water in flush cycle 8 Salt water hose 9 Sa...

Страница 3: ...he circuit is being flushed 4 Flush cell button Press this button to flush the electrolytic cell The red lamp flashes while the cell is being flushed 5 Sensor lamp blue Illuminates when the sensor det...

Страница 4: ...ER SUPPLY LINE IMPORTANT 1 Use potable water only Use of non potable water may cause corrosion clogged pipes or health problems 2 The water supply pressure must be within 0 1 to 0 75 MPa 100 to 750 kP...

Страница 5: ...Gasket Union Elbow Hose Clamp Braided Hose Connector Receptacle Remote Controller Back Front Panel Hose Clamp Remote Cable Screw 2 on each side Put through Remove and bind Remove grommet and fix remot...

Страница 6: ...ual water hardness is not measured the unit regards the hardness as 200 mg L default setting resulting in a longer cell flush cycle If the display shows FAIL measure the hardness again after a trial r...

Страница 7: ...ability under the terms of the warranty are limited and shall exclude routine servicing cleaning essential maintenance and or repairs occasioned by misuse and installations not in accordance with Hosh...

Отзывы: