8. INSPECTION

Use a copy of “12. [a] DAILY INSPECTION SHEET” and “12. [b] 

MONTHLY INSPECTION SHEET” to keep records.

[a] pH, AVAILABLE CHLORINE CONCENTRATION (DAILY)

1) Drain more than 1 liter each of sanitizing water and cleaning water. 

Sample each water from its outlet into separate containers.

2) Use the pH and chlorine test papers to check that each value is 

within the following range.

Water

Test Paper

pH

Available Chlorine

Sanitizing

pH test paper UNIV Acidic range

Chlorine test paper

20 mg/kg (ppm)

or more

Cleaning

pH test paper UNIV Approx. 11

* It is not necessary to check the available chlorine concentration of 

cleaning water.

Note: See the instruction manual of each test paper for details of its 

proper handling.

 

If any of the checked values exceeds the specified range, 

contact an authorized Hoshizaki service company.

 

If water is not dispensed from its proper outlet, contact an 

authorized Hoshizaki service company.

[b] SALT WATER LEVEL (DAILY)

Check the salt water level according to “2. [a] CHECKING AMOUNT 

OF REMAINING SALT WATER”.

[c] WATER LEAKS (DAILY)

Check the unit and surrounding floor for water leaks. If any is found, 

contact an authorized Hoshizaki service company.

[d] REPLACE CELL LAMP (DAILY)

Check that the replace cell lamp on the operation panel is not flashing. 

The service life of the electrode in the electrolytic cell depends on 

water quality. To maintain effective performance of electrolyzed 

water, the electrolytic cell needs to be replaced every 3000 hours of 

operation.

If  the  replace  cell  lamp  is  flashing,  contact  an  authorized  Hoshizaki 

service company.

[e] CELL RUN TIME, CURRENT, VOLTAGE (AS REQUIRED)

To check the cell run time, current, and voltage:

1) Open the door.

2) Turn on the power switch (

earth leakage circuit breaker).

3) Press the display select button on the control panel.

4) Press the display select button until the desired item appears in the 

display.

Note: It is factory adjusted to display the cell run time first.

5) Close the door.

[f] WATER HARDNESS (WEEKLY)

IMPORTANT

Continuous use with hard water may cause clogged pipes, 

reduction in performance, or failure of the electrolytic cell. If 

sampled water is hard, contact an authorized Hoshizaki service 

company.

1) Open the water sampling tap. Let water run for more than 5 

seconds. Sample water in the measuring cup.

2) Pour one or two drops of the water hardness indicator into the 

measuring cup, and stir a little. Check the water hardness (red = 

hard water, blue = soft water).

Note: For details, follow the instructions of the water hardness 

indicator.

[g] EARTH LEAKAGE CIRCUIT BREAKER (MONTHLY)

WARNING

Check the earth leakage circuit breaker for proper operation 

once a month. If it is left inoperable, it could increase the risk of 

electric shock in case of electric leak.

1) Press the test button of the power switch 

(earth leakage circuit breaker).

2) Check that the switch turns off. If not, 

immediately contact an authorized 

Hoshizaki service company.

[h] EARTH WIRE, ATTACHMENT PLUG (ANNUALLY/BIANNUALLY)

WARNING

Check periodically that the attachment plug blades and their 

vicinity are free of dust and that the attachment plug is securely 

plugged into the receptacle. Dusty blades or loose connection 

may cause electric shock or fire.

Check for the following problems:

Problem

Remedy

The earth wire is broken or loosely 

connected.

Ask an authorized Hoshizaki 

service company or licensed 

electrician for repair.

The attachment plug or power cord is 

too hot, damaged, weighed down, or 

caught in.

Immediately ask an 

authorized Hoshizaki service 

company for repair.

The attachment plug blades, their 

vicinity, and receptacle are dusty.

Clean.

The attachment plug is plugged into a 

single receptacle with other equipment.

Plug into a separate 

receptacle.

The unit shares a single power supply 

with other equipment.

Use a separate power supply.

[i] CONSUMABLE/PERIODIC REPLACEMENT PARTS

Consumable parts:

 

pH test paper UNIV  

Chlorine test paper

 

Water hardness indicator 

Neutralizing agent

Periodic replacement parts:

 

Electrolytic cell (3000 hours)

9. PREPARING ELECTROLYZER FOR LONG STORAGE

WARNING

When shutting down the electrolyzer for more than a week, turn 

off the power switch (earth leakage circuit breaker), and unplug 

the unit to prevent electric leak, heat generation, or ignition.

OFF

Test button

Содержание ROX-20TB2-EW

Страница 1: ...ROX 20TB2 EW L1X002114 032017 WATER ELECTROLYZER FOR END USER INSTRUCTION MANUAL 3 16 Minamiyakata Sakae Toyoake Aichi 470 1194 Japan...

Страница 2: ...th acidic or chlorine based chemicals can cause chlorine gas resulting in health problems 5 Do not use a large volume of sanitizing water only Generation of a large amount of chlorine gas may cause he...

Страница 3: ...ter outlet Discharges electrolyzed water 6 Add salt water lamp red Indicates that the salt water tank level is too low Flashes when the error lamp on the operation panel lights up 7 Ready lamp green F...

Страница 4: ...by siphonage and the unit may fail to operate properly 4 START UP 1 Plug in the unit 2 Open the water supply line shut off valve 3 Check for proper operation of the water softener Refer to the instru...

Страница 5: ...er pipe with scale for a long period of time may prevent the flow of cleaning water stop the unit or cause poor performance To prevent scale from accumulating flush the cleaning water pipe periodicall...

Страница 6: ...may cause clogged pipes reduction in performance or failure of the electrolytic cell If sampled water is hard contact an authorized Hoshizaki service company 1 Open the water sampling tap Let water ru...

Страница 7: ...Drain salt water from the salt water tank and rinse the inside the salt water tank to remove salt completely with tap water 4 Fill the salt water tank with tap water and connect the salt water hose 5...

Страница 8: ...tion Salt water level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by Sanitizing water only Date Time pH Sanitizing water Cleani...

Отзывы: