Hoshizaki ROX-20TB2-EW Скачать руководство пользователя страница 3

2

[6] Flush button

Functions as a switch to flush the pipes beyond the sanitizing and 

cleaning water outlets. Also functions as down button to decrease the 

set values.

[7] Flow rate lamp

Indicates the currently selected flow rate.

[8] Flow rate select button

Adjusts the flow rate.

[9] Set/reset button

Only qualified service personnel or installer may press this button to 

adjust various set values.

[10] Power switch

Turns the unit on and off.

Note: When the low flow rate is selected, sanitizing water may have 

an  excessive  available  chlorine  concentration.  Select  this  flow 

rate only when the electrolyzed water property is inadequate.

[c] OPERATION PANEL

[1] Error lamp (red)

Indicates that there is trouble detected.

[2] Replace cell lamp (red)

Indicates that the cell life is near completion. Flashes continuously 

from 2900 hours to 3000 hours and stays on after 3000 hours.

[3] Flush lamp (red)

Stays on during the flush operation. Indicates that the unit is in flush 

cycle.

[4] Add salt water lamp (red)

Indicates that the salt water tank level is too low.

[5] Ready lamp (green)

Flashes until the desired settings are achieved and stays on when the 

unit is dispensing electrolyzed water.

[6] Operation lamp (green)

Indicates that the unit is running.

[7] Dispense button

Starts and stops dispensing electrolyzed water.

[d] REMOTE CONTROLLER

[1] Continuous dispense lamp (green)

Lights in the continuous dispensing mode which is activated or 

disactivated by pressing the dispense button or putting a hand or 

object in front of the dispensing sensor on the left.

[2] Dispense button

Starts and stops dispensing electrolyzed water in the continuous or 

portion control dispensing mode.

[3] Electrolyzed water lamp (green, orange)

Indicates the cleaning water and sanitizing water outlets.

[4] Dispensing sensor

Senses a hand or object to start and stop dispensing electrolyzed 

water without using the dispense button.

[5] Electrolyzed water outlet

Discharges electrolyzed water.

[6] Add salt water lamp (red)

Indicates that the salt water tank level is too low. Flashes when the 

error lamp on the operation panel lights up.

[7] Ready lamp (green)

Flashes until the desired settings are achieved and stays on when the 

unit is dispensing electrolyzed water.

[8] Handwash button

Starts and stops dispensing electrolyzed water in the handwash 

mode.

[9] Handwash lamp (green)

Lights in the handwash mode which is activated or disactivated by 

pressing the handwash button or putting a hand or object in front of 

the dispensing sensor on the right. The electrolyzed water lamps light 

up  in  turn  to  indicate  the  proper  handwashing  steps  -  first  cleaning, 

then sanitizing (adjustable from 15 to 120 seconds each).

[10] Portion control lamp (green)

Lights in the portion control dispensing mode which is activated by 

pressing the dispense button for 3 seconds or putting a hand or object 

in front of the dispensing sensor on the left for 3 seconds. Water 

automatically stops after the set dispense time indicated in the display 

on the control panel (adjustable from 1 to 60 minutes).

Note: To avoid unbalancing the water properties or causing water 

leaks, do not block the water outlets.

 

The dispensing sensor may react with reflective materials such 

as glass and metal, even outside the normal detection range.

[e] ACCESSORIES

Connector 

pH test paper UNIV  Chlorine test paper

Instruction manual 

Installation manual 

Operation sheet

Cap 

Gasket 

Pressure reducing valve

Water supply hose 

Braided hose 

Measuring cup

Salt water tank 

Clamp 

Rubber dropper

XM Connector (5P)*  Dual check valve 

Nipple

[1] [2] [3] [4] [5] [6] [7]

[1]

 [2]

 [3]

[4]

[5]

[10]

[9]

 [8]

 [7]

 [6]

* To operate the unit in the pool mode, replace the XM 

connector (5P) [red] on the rear of the control box 

with the accessory XM connector (5P) [blue]. See “II. 9. 

[a] OPERATION MODE” in the installation manual.

2. CHECKS BEFORE OPERATION

[a] CHECKING AMOUNT OF REMAINING SALT WATER

1) Check that there is enough salt water in the salt water tank.

2) Add salt water according to “[b] SUPPLYING SALT WATER” if there 

is not enough or no salt water in the tank.

Содержание ROX-20TB2-EW

Страница 1: ...ROX 20TB2 EW L1X002114 032017 WATER ELECTROLYZER FOR END USER INSTRUCTION MANUAL 3 16 Minamiyakata Sakae Toyoake Aichi 470 1194 Japan...

Страница 2: ...th acidic or chlorine based chemicals can cause chlorine gas resulting in health problems 5 Do not use a large volume of sanitizing water only Generation of a large amount of chlorine gas may cause he...

Страница 3: ...ter outlet Discharges electrolyzed water 6 Add salt water lamp red Indicates that the salt water tank level is too low Flashes when the error lamp on the operation panel lights up 7 Ready lamp green F...

Страница 4: ...by siphonage and the unit may fail to operate properly 4 START UP 1 Plug in the unit 2 Open the water supply line shut off valve 3 Check for proper operation of the water softener Refer to the instru...

Страница 5: ...er pipe with scale for a long period of time may prevent the flow of cleaning water stop the unit or cause poor performance To prevent scale from accumulating flush the cleaning water pipe periodicall...

Страница 6: ...may cause clogged pipes reduction in performance or failure of the electrolytic cell If sampled water is hard contact an authorized Hoshizaki service company 1 Open the water sampling tap Let water ru...

Страница 7: ...Drain salt water from the salt water tank and rinse the inside the salt water tank to remove salt completely with tap water 4 Fill the salt water tank with tap water and connect the salt water hose 5...

Страница 8: ...tion Salt water level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by Sanitizing water only Date Time pH Sanitizing water Cleani...

Отзывы: