S8E V2.5 Hi-Carb Superchiller
230V / 50Hz
www.lancerbeverage.com
Page 10 of 31
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000016
Images are for illustration purposes only as product may vary.
No 038 – 21 October 2014
6.4
Mounting Superchiller
Install on a flat, level surface using adjustable legs or casters (Optional).
Fix to supporting structure using 4 x ¾” BSW bolts screwed into base supports.
Caution
Superchiller operational weight is 394kg; ensure that all
supporting structures are certified for this loading by a
registered Mechanical Engineer.
Supporting structure must be securely fixed to floors or walls.
6.5
Connecting Python
Connect Python to Chiller and Dispenser.
Caution
NOTE: The S8E Superchiller is rated to operate with a maximum
of 90m of python connected at 32
°C
.
Exceeding manufacturer’s ratings may cause damage to the
Superchiller and void warranty.
Connect the Python to Chiller and Dispenser.
Refer to Python and Dispenser specifications for connection data.
Superchiller can be supplied with 4 or 5 pumps, dual carbonator, or 3 pumps single carbonator;
python should be connected to Chiller as follows:
5 Pump
4 Pump
3 Pump
SODA
RETURN A
WATER
RETURN
SODA
RETURN B
SODA
RETURN A
SODA
RETURN B
SODA
RETURN A
WATER
RETURN
SODA
SUPPLY A
WATER
SUPPLY
SODA
SUPPLY B
SODA
SUPPLY A
SODA
SUPPLY B
SODA
SUPPLY A
WATER
SUPPLY
Important
: Ensure lines from python to Superchiller connections are insulated to prevent
condensation.
Note
: For additional Soda reserve on short python lengths used in high volume accounts, it may be
necessary to extend the soda circuit by connecting the 2 spare lines in the python onto the soda
return line (i.e. double pass of soda circuit out and back from dispense point to soda return).
SODA SUPPLY
SODA RETURN
10mm 'U' BEND
PYTH
ON