Remove sanitising fittings from BIB disconnects and re-connect disconnects to appropriate
BIB's. Operate dispensing valves until syrup flows freely.
7. Scheduled
Maintenance
The following Superchiller routine maintenance should be performed at the intervals listed.
7.1. Daily
Cleaning/Sanitising
The Superchiller supplies soda water to the dispensing valves/barguns. To ensure optimum drink
quality and system performance at all times please follow cleaning and sanitising procedures for the
dispensing valves/barguns recommended by the valve/bargun manufacturer.
Checking CO
2
Supply
Ensure that the contents gauge on the CO
2
Regulator reads higher than 1400kpa on the dial. If it
does not, then the CO
2
cylinder is empty and must be changed using safe working practices.
Warning
To avoid personal injury and/or property damage, always
secure the CO
2
cylinder with a safety chain to prevent it from
falling over; and use appropriate protective equipment (as
defined in Clause 3.3.2 of AS 5034) to handle cylinders.
Should the valve become accidentally damaged or broken
off, a CO
2
cylinder can cause serious personnel injury.
7.2. Quarterly
The Superchiller should be connected to a filtered water supply. To ensure optimum drink quality and
system performance, supply water filters should be replaced every 3 months.
7.3. Half Yearly
Remove & Clean condenser filters on the Superchiller. When the environment is dirty and
dusty, the interval between cleaning the filters may need to be reduced. Clean condenser with
low pressure compressed air. When using compressed air always direct air from the fan side
through condenser. Remove all dust and foreign particles from refrigeration deck.
Caution
When using compressed air always wear safety glasses.
Check that the water is level with the top of the overflow tube. Add water if necessary.
Open carbonator relief valve to purge CO2 and check leakage, close relief valve after checking.