background image

Glycoolpac 27hx Manual

  

 

 

www.lancerbeverage.com

 

Page 19 of 21

 

Hoshizaki Lancer reserve the right to change specifications without notice. 

Part No 68000204 

Images are for illustration purposes only as product may vary.  

No 024 – 27 November 2013 

11.4  GP27 HX Pump Assembly 

 

REF PART 

NO. DESCRIPTION 

79619861 

PUMP INSULATOR SPK GLYCOOLPAC 

87273075 

PUMP SPK2-11 GRUNDFOS 1PH 

66619988 

PROPELLER ADAPTOR SPK PUMP 

87620001 

PROPELLER SPK PUMP GP27 

79000244 

DIRECTOR BRASS 1BARB X 3/4 BSP 

79000113 

PLUG BLANKING CLEAR CP9X 

79620723 

WASHER SPRING S/S M08 

83000058 

GROMMET WATER TIGHT 16MM 

83000308 

IEC LEAD MALE SPLASHP 300MM 

NOTE! 

IF REPLACING ITEM 3 THE 

ASSEMBLY MUST BE 

TIGHTENED IN SEQUENCE 

ACCORDING TO  

SOP-PRD-026 

Содержание Lancer Glycoolpac 27hx

Страница 1: ...www lancerbeverage com Installation Operation Service Manual Glycoolpac 27hx Self Contained Glycol Chiller...

Страница 2: ...Installation 8 6 1 Receiving 8 6 2 Unpacking 8 6 3 Selecting and Preparing the Location 8 6 4 Connecting Glycol Lines and Glycol Tank Overflow 9 6 5 Filling Unit with Glycol Water 9 6 6 Connecting to...

Страница 3: ...r is in turn ultimately owned by Hoshizaki Electric Co Ltd of Nagoya Japan Hoshizaki is a global leader in food service equipment Hoshizaki Lancer s head office and manufacturing base is located in Ad...

Страница 4: ...less refrigerant than previous coil models Digital Thermostat with 1 button energy saving ECO Mode off peak temperature setting Rugged and dependable with low installation operation and maintenance co...

Страница 5: ...fications Dimensions Width 680 mm Depth 680 mm Height 1180 mm 1330 with legs Weight Shipping 129 kg Empty 114 kg Operating 315 kg Refrigerant R404A Power Supply 240V 50Hz 15A Standard Model 10 6 amps...

Страница 6: ...manual To prevent personal injury or damage to the machine these alerts must be strictly adhered too Danger Alerts to an existing hazardous situation that if not avoided WILL result in death serious i...

Страница 7: ...Images are for illustration purposes only as product may vary No 024 27 November 2013 5 4 Service Caution Installation of this unit and service work should only be performed by fully trained certified...

Страница 8: ...tical Do not lay Glycoolpac 27hx on its back or sides Remove shipping carton and pallet from Glycoolpac 27HX If appropriate assemble legs to base of unit by carefully tilting unit Tilt should be no mo...

Страница 9: ...oir may be used to collect overflow but it must be emptied regularly Caution Glycol is a very slippery substance Any spills should immediately be cleaned up to prevent slipping hazards 6 5 Filling Uni...

Страница 10: ...plate on the appliance for the electrical supply requirements The service of a licensed electrician may be required to ensure the installation is in accordance with the local codes and regulations War...

Страница 11: ...ng the UP or DOWN arrow keys then press the SET key to display its value Press the UP or DOWN key to change its value Press the SET key to store the new value and move to the next parameter To exit fr...

Страница 12: ...m the cut out point by this value before the refrigeration turns on AF F 5 0 Antifreeze alarm set point If the evaporator suction line reaches this temperature the control will stop the refrigeration...

Страница 13: ...y before commencing any service or maintenance Switch the unit OFF and disconnect unit from power supply Check water glycol level Check water glycol concentration using refractometer see chart Remove...

Страница 14: ...ge Defective thermal overload Check wiring connections Fan motor bearings tight or seized Incorrect differential setting Clean condenser of all lint and dirt Check for air restriction to condenser Che...

Страница 15: ...ancerbeverage com Page 15 of 21 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000204 Images are for illustration purposes only as product may vary No 024 27 Nove...

Страница 16: ...19629 BODY TANK ASSY GLYCOOLPAC 27 2 62619915 EVAP ASSY GLYCOLPAC 27HX 3 61619939 UNIT DECK ASSY GP27HX 4 61619952 TANK COVER ASSY GLYCOOLPAC 27 5 84000025 CONDENSER GP27HX INDUS 6 78619909 PUMP AGI A...

Страница 17: ...4217 VERTICAL BRACE GLYCOOL R P 3 79633717 NUT S S M08 HEX 4 62000127 SUCTION LINE HX TO DECK GP27HX 5 79600041 Reducer Copper 11 8 ODx1 2 ID 6 62000123 LIQUID LINE TXV TO HX GP27HX 7 87600230 TX VALV...

Страница 18: ...REF PART NO DESCRIPTION REF PART NO DESCRIPTION 1 88645628 ELECTRICAL BOX BLANK 9 83000058 GROMMET 4 PER 2 83600811 MINI CONTACTOR 10 83000054 COMPRESSOR LEAD 3 83000221 JUMPER WIRES 4 PER 11 83000306...

Страница 19: ...embly REF PART NO DESCRIPTION 1 79619861 PUMP INSULATOR SPK GLYCOOLPAC 2 87273075 PUMP SPK2 11 GRUNDFOS 1PH 3 66619988 PROPELLER ADAPTOR SPK PUMP 4 87620001 PROPELLER SPK PUMP GP27 5 79000244 DIRECTOR...

Страница 20: ...arts Equipment warranty claim Subject to the approval of the Divisional Sales Manager Hoshizaki Lancer may choose to reimburse the customer for some or all labour costs associated with a warranty clai...

Страница 21: ...d quietly Pump fitted Pump type propeller fitted spinning freely Check all tube work for rubbing e g discharge line liquid line etc Condenser not touching grille Check probe positions and tightness Gl...

Отзывы: