Glycoolpac 27hx Manual
www.lancerbeverage.com
Page 13 of 21
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No 68000204
Images are for illustration purposes only as product may vary.
No 024 – 27 November 2013
8. Monthly
Maintenance
Warning
Glycoolpac 27hx MUST be isolated from electrical supply before
commencing any service or maintenance
Switch the unit OFF and disconnect unit from power supply.
Check water/glycol level.
Check water/glycol concentration using refractometer (see chart).
Remove lid and grille.
Clean condenser with a soft brush or low pressure air. (If using compressed air, always blow from the
fan side of the condenser)
Remove any dust from refrigeration deck.
Replace lid and grille.
Reconnect to power the supply and switch the unit ON.
Caution
When using compressed air- always wear protective eye wear.